Genie Application Software CD

 

This CD is designed to give technicians the files needed to adjust, update, and download the software loaded onto the control cards on Genie self-propelled booms reaching 40 feet or higher and SmartLink.  The definitions given below coordinate with the columns in the table on the following page. 

 

 

Definitions:

 

Model – Machine model and control module (if applicable)

 

SER. # – Serial number of the machine

 

Inc. Date – Incorporation date for the software or hardware change/release. 

 

Hardware Assembly Part # – Genie part number for the control board with the software loaded with the defined Software Revision. 

 

Software Revision – Revision level of the software.

 

Microcontroller Type – The type of processor on each control board.  This is used when downloading boot files, kernel files, or application files.

 

PC Install Program – Self-extracting files that install the needed files onto your PC/laptop for use with the WebGPI program for that software application.  The WebGPI program can be ordered from Genie service parts department. 

 

Boot File – This HEX file is needed on some control boards to load the kernel. 

 

Kernel File – This HEX file setups up the Microcontroller to accept the application program. 

 

PDA xml File – The xml file is used with a Palm handheld and WebGPI-PDA program to display and adjust the application information on the control board using the PDA screen.  The WebGPI-PDA program can be ordered from Genie service parts department. 

 

WebGPI/WebGPI-PDA Application File – This HEX file holds all the values for the valve thresholds, valve max output, propel, and all functions controlled by the control board.  This file is what that the board uses to control the boom functions. 

 

Cat5 Cable - An electrical cable used to connect one electronic device to another for signal routing.

 

Web Browser - A software application for retrieving, presenting, and traversing information resources.  Common types include Microsoft Internet Explorer, Google Chrome and Mozilla Firefox.  This is the software used to view the service tool application on smartLinkTM machines.

 

SmartLinkTM- This is the name of the new control systems developed totally in house by the Terex AWP Controls Engineering Team.  Machine hardware will display the smartLinkTM logo helping to identify the type of control system on the machine.

 

SmartLinkTM

 

Software:

WebGPI software 1.01a or later– Genie part number 62458 (Need Internet Explorer 5 or later) 

 

WebGPI PDA – Version 1.30, Build 27 Genie part number 83045

 

WebGPI Interface Procedure

 

WebGPI-PDA Interface Procedure

 

WebGPI Kernel Download Procedure

 

WebGPI Application Download Procedure  

 

WebGPI Application Download Procedure for ALC500 Gen II PCB 

 

WebGPI-PDA Application Download Procedure

 

Obtaining Plus+1 Service and Diagnostic Tool

 

Connecting to Plus+1 on S60HC

 

Updating Plus+1 Software on S60HC

 

Connecting to Plus+1 on Z40

 

Updating Plus+1 Software on Z40

 

Z40 Rev A to Rev C Upgrade Info

 

Z40 Rev B to Rev C software Upgrade Info and Procedure

 

Z40 Rev C to Rev D software Upgrade Info and Procedure

 

Program ALC500 using the Jumper Wires

 

MODEL

SER. #

Inc. Date

Hardware Assembly Part #

Software Revision

Microcontroller Type

PC Install Program (.exe)

Boot File (.hex Need before Kernel File Download)

Kernel File (.hex)

PDA xml File (view/adjust program on board with PDA)

WebGPI / WebGPI-PDA Application File (.hex)

Backward compatible

Applicable Engines

Comments

S80/85

3082

4.8.02

81542

Rev. 1.00

HC12

S0513100

N/A

L0082100

S0513100 PDA

S0513100

S0513222

DF4L913  FORD EFI  GM 3.0L  P704-33

Low current drive output used only on S80/85 S/N’s 3082-3423.  Do not attempt to download Revisions other than 1.00 onto this board.  Units that have had the boards replaced after 10/15/02 will have revision 2.04 or 2.22 software.

3424

10.15.02

89353

Rev. 2.04

HC12

S0513204

N/A

L0082101

S0513204_PDA

S0513204

S0718103

 

Rev. 2.04 improves the reset to Z45N anomaly.

3487

2.4.03

89353

Rev. 2.22

HC12

S0513222

N/A

L0082101

S0513222_PDA

S0513222

*Rev. 2.22 corrects reset to Z45N and is backward compatible for all 89353 applications.

4076

1.6.05

102625

Rev. 1.00

HC12

S0718100

 

N/A

L0082101

S0718100_PDA

S0718100

DEUTZ 4CYL   FORD EFI  P804C        GM 3.0L

Separated from S0513222 and add brake release on steer.  Tier II parameters filled in manually until release.

5861

5.21.07

122271

Rev. 1.01

HC12

S0718101

N/A

L0082101

S0718101_PDA

S0718101

DEUTZ 4CYL   FORD EFI  P804C

GM 3.0L        Continental TME27

Added Continental TME27 engine option, added turntable rotate Stow/No stow transition ramp, adjusted turntable rotate default parameters.

5898

6.11.07

122271

Rev. 1.02

HC12

S0718102

N/A

L0082101

S0718102_PDA

S0718102

DEUTZ

4CYL

TME27

P804C

Bug fix - removed conditional speed limit for turntable rotate when boom angle was greater than 15 degrees

7140

6.16.08

122730

Rev. 1.03

HC12

S0718103

N/A

L0082101

S0718103_PDA

S0718103

DEUTZ 2011L04i  

TME27 

Perkins P804

- Add Tier 3 engines –Standardized on Jumper Configuration pins (J5,J6) for engines and models,  -Add low/high current propel pump option –Fixed footswitch issue when set to lockout –Fixed footswitch water ingress causing “Valve to low” fault.

3082-7999

11.4.10

T110570

Rev. 1.00

164/TI

S0821100

ONLY FOR VIEWING UPGRADE TO S0821201

N/A

N/A

N/A

N/A

S0821201

-          Initial Release software for ALC500 GenII PCB only

-          Add footswitch priority

 

9.25.11

235403

Rev. 2.01

164/TI

S0821201

NA

NA

NA

NA

 

- Fixed issue with footswitch not forcing timeout when held on startup.

- Convert from prototype WebGPI library to 3.10 released library.
- Modifications to footswitch logic and settings to prevent nuisance faults.
- Widened valve max adjustment to pass stowed condition.
- Added drive enable timer to allow for propel shuttling without hitting bypass button.

- Kernel application layer changed to correct random changes to 60% current output.  ECN# 11605B

 

 

 

 

 

 

 

 

 

 

 

 

 

S80/85 – 2008

8000-8496

9.22.08

121458

Rev. 1.00

HC12

S0780100

N/A

L0082101

NA

N/A

S0819202

DEUTZ

2011L04i  

TME27 

Perkins P804

-          Initial Release software for ALC500 GenII PCB only

-          Add Dual Capacity option

Add footswitch priority

8496

8.31.10

139745

Rev. 1.00

164/TI

S0819100

ONLY FOR VIEWING UPGRADE TO S0819202

NA

NA

NA

S0819100

8611

11.8.10

T115457

Rev. 1.01

164/TI

S0819101

ONLY FOR VIEWING UPGRADE TO S0819202

NA

NA

NA

N/A

Corrected low voltage issue with Steer and added voltage check for valve power vs. ECU power

8970

9.25.11

235322

Rev. 2.02

164/TI

S0819202

N/A

N/A

N/A

N/A

-Fixed issue with footswitch not forcing timeout when held on startup.

-Convert from prototype WebGPI library to 3.10 released library.
2. Added missing angle sensor screen to installer.
-Fixed calibration issue - Boom stow/out of stow propel speed.
-Nuisance Fault GenII - Monitor added to detect floating ground.
-Corrected VBatt calculation.
-Fixed - Min fault current does not always follow the higher of the calibrated thresholds.
-Kernel application layer changed to correct random changes to 60% current output.
-Fixed - Cannot change the stow/out-of-stow values if not in that position.
-Fixed Drive Enable operation while transitioning through joystick neutral. (ecn#11605)

 

 

 

 

 

 

 

 

 

 

 

 

 

Z45/25 IC

21180

10.10.02

89353

Rev. 2.04

HC12

S0513204

N/A

L0082101

S0513204_PDA

S0513204

 S0843100

DF31011F    FORD EFI    P404C

Rev. 2.04 improves the reset to Z45N anomaly.

21564

2.4.03

89353

Rev. 2.22

HC12

S0513222

N/A

L0082101

S0513222_PDA

S0513222

*Rev. 2.22 corrects reset to Z45N.  89353 was replaced by 236812

22051

6.10.03

94773

Rev. 1.00

HC12

S0662100

N/A

L0082101

S0662100_PDA

S0662100

S0662100

DEUTZ 3CYL   FORD EFI    P404C

High current drive output and proportional directional valves, not separate proportional and directional valves.

23385

5.3.04

106348

Rev. 1.01

HC12

S0662101

N/A

L0082101

S0662101 PDA

S0662101

S0824200

Tier II engines, add rocker steer as a pin select option. Rev. 1.02 never release to production.

27000

9.21.05

110164

Rev. 1.03

HC12

S0662103

N/A

L0082101

S0662103 PDA

S0662103

-Recall all default values when valid model selection jumpers are detected -Corrected the Motor Speed logic to keep the output ON during the kSpeedShftLow state -Added an OFF delay feature for the Propel brake -Modified several default values due to Function Manifold changed– Modified joystick Cal values –Change Motor shift function.

 

30142

8.15.06

110164

Rev. 1.04

HC12

S0662104

N/A

L0082101

S0662104_PDA

S0662104

DEUTZ 3CYL                      FORD EFI   P404C     FORD FI2.3L

Add new 2.3L Ford engine parameters

38093

6.23.08

110164

Rev. 1.04

HC12

S0662104

N/A

L0082101

S0662104_PDA

S0662104

Manually change Pulse/Rev of P404C engine from 8.9 to 10.6

Rev 1.05 never release to production

38511

7.30.08

139502

Rev. 1.06

HC12

S0662106

N/A

L0082101

S0662106_PDA

S0662106

Ford EFI 2.5L

Perkins 404C

Ford EFI 2.3L

Deutz 2011L03

Perkins 404D

-          Add Tier 3 engines –Standardized on Jumper Configuration pins (J5,J6) for engines and models,  -Add low/high current propel pump option –Fixed footswitch issue when set to lockout –Fixed footswitch water ingress causing “Valve to low” fault.

 

40522

01/11/11

T110562

Rev. 1.00

164/TI

S0824100

N/A

N/A

N/A

N/A

-          Initial Release software for ALC500 GenII PCB only

Add footswitch priority

42621

9.29.11

235473

Rev. 2.00

164/TI

S0824200

N/A

N/A

N/A

N/A

- Nuisance Fault GenII - Monitor added to detect floating ground.
- Corrected VBatt calculation.
- Kernel application layer changed to correct random changes to 60% current output.
- Fixed Drive Enable operation while transitioning through joystick neutral.
- Fixed issue with footswitch not forcing timeout when held on startup. (ecn#11670b)

 

 

 

 

 

 

 

 

 

 

 

 

 

Z51M

101

10.3.2005

110157

Rev. 1.00

HC12

S0717100

N/A

L0082101

S0717100 PDA

S0717100

S0826200

DEUTZ 3CYL       

Release software

503

8.1.08

139505

Rev. 102

HC12

S0717102

N/A

L0082101

S0717102 PDA

S0717102

Ford EFI 2.3L

Deutz 2011L03

Perkins 404D

Add Tier 3 engines –Standardized on Jumper Configuration pins (J5,J6) for engines and models,  -Add low/high current propel pump option –Fixed footswitch issue when set to lockout –Fixed footswitch water ingress causing “Valve to low” fault.

Rev 1.01 never release to production.

664

3.5.11

T110563

Rev. 1.00

164/TI

S0826100

N/A

N/A

N/A

N/A

-          Initial Release software for ALC500 GenII PCB only

-          Add footswitch priority

 

???

???

 

235414

Rev. 2.00

164/TI

S0826200

N/A

N/A

N/A

N/A

- Nuisance Fault GenII - Monitor added to detect floating ground.
- Corrected VBatt calculation.
- Kernel application layer changed to correct random changes to 60% current output.
- Fixed Drive Enable operation while transitioning through joystick neutral.
- Fixed issue with footswitch not forcing timeout when held on startup. (ecn#11673b)

 

 

 

 

 

 

 

 

 

 

 

 

 

Z45M

101

3.29.07

110164

Rev. 1.04

HC12

S0662104

N/A

L0082101

S0662104_PDA

S0662104

S0824200

DEUTZ 3CYL                      FORD EFI   P404C     FORD FI2.3L

Add new 2.3L Ford engine parameters

1423

7.31.08

139502

Rev. 1.06

HC12

S0662106

N/A

L0082101

S0662106_PDA

S0662106

Ford EFI 2.5L

Perkins 404C

Ford EFI 2.3L

Deutz 2011L03

Perkins 404D

- Add Tier 3 engines –Standardized on Jumper Configuration pins (J5,J6) for engines and models,  -Add low/high current propel pump option –Fixed footswitch issue when set to lockout –Fixed footswitch water ingress causing “Valve to low” fault.

Rev 1.05 never release to production.

1738

3.5.11

T110562

Rev. 1.00

164/TI

S0824100

N/A

N/A

N/A

N/A

-          Initial Release software for ALC500 GenII PCB only

Add footswitch priority

???

???

235473

Rev. 2.00

164/TI

S0824200

N/A

N/A

N/A

N/A

- Nuisance Fault GenII - Monitor added to detect floating ground.
- Corrected VBatt calculation.
- Kernel application layer changed to correct random changes to 60% current output.
- Fixed Drive Enable operation while transitioning through joystick neutral.
- Fixed issue with footswitch not forcing timeout when held on startup. (ecn#11673b)

 

 

 

 

 

 

 

 

 

 

 

 

 

Z60/34

4001

8.12.02

89353

Rev. 2.00

HC12

S0513200

N/A

L0082101

S0513200_PDA

S0513200

S0825200

DF31011F    FORD EFI    P404C

Rev. 2.00 and above is capable of high current drive output.  Should be upgraded to Rev. 2.22

 

 

89353

Rev. 2.04

HC12

S0513204

N/A

L0082101

S0513204_PDA

S0513204

Rev. 2.04 improves the reset to Z45N anomaly.

4169

2.2.03

89353

Rev. 2.22

HC12

S0513222

N/A

L0082101

S0513222_PDA

S0513222

See comment above *.

4551

4.08.04

102750

Rev. 1.00

HC12

S0690100

N/A

L0082101

S0690100_PDA

S0690100

DEUTZ 3CYL   FORD EFI   P404C   

Separated from S0513222 and is now a low current drive pump.

6107

6.03.06

102750

Rev. 1.01

HC12

S0690101

N/A

L0082101

S0690101_PDA

S0690101

Add brake release when steer, brake off delay, rocker steer as a pin selection option.

6388

8.10.06

102750

Rev. 1.02

HC12

S0690102

N/A

L0082101

S0690102_PDA

S0690102

DEUTZ 3CYL   FORD EFI   P404C     FORD EFI2.3L

Add new 2.3L Ford engine parameter choice and Hi / Low Current drive pump options.

9699

11.24.08

122924

Rev. 1.03

HC12

S0690103

N/A

L0082101

S0690103_PDA

S0690103

DEUTZ 2011L03 PERKINS

404C PERKINS 404D FORD EFI

2.5L FORD EFI

2.3L

- Add Tier 3 engines –Standardized on Jumper Configuration pins (J5,J6) for engines and models,  -Add low/high current propel pump option –Fixed footswitch issue when set to lockout –Fixed footswitch water ingress causing “Valve to low” fault.

10179

11.8.10

T110571

Rev. 1.00

164/TI

S0825100

N/A

N/A

N/A

N/A

-          Initial Release software for ALC500 GenII PCB only

-          Added footswitch priority

 

10813

9.12.11

235476

Rev. 2.00

164/TI

S0825200

NA

NA

NA

NA

. Fixed issue with footswitch not forcing timeout when held on startup.
- Convert from prototype WebGPI library to 3.10 released library.
- Nuisance Fault GenII - Monitor added to detect floating ground.
- Corrected VBatt calculation.
- Kernel application layer changed to correct random changes to 60% current output.
- Fixed Drive Enable operation while transitioning through joystick neutral. (ecn11671b)

 

 

 

 

 

 

 

 

 

 

 

 

 

S40/45

7001

3.7.03

94771

Rev. 1.01

HC12

S0648101

N/A

L0082101

S0648101_PDA

S0648101

S0823202

DEUTZ 3CYL   FORD EFI   P404C    

Release software

7569

4.01.04

102259

Rev. 1.02

HC12

S0648102

N/A

L0082101

S0648102_PDA

S0648102

Tier II parameter and 2 speed implementation.

11189

8.10.06

102259

Rev. 1.05

HC12

S0648105

N/A

L0082101

S0648105_PDA

S0648105

DEUTZ 3CYL   FORD EFI   P404C     FORD EFI2.3L

Add new 2.3L Ford engine parameter choice and Hi / Low Current drive pump options;  Rev 1.03 and 1.04  never release to production

15581

11.24.08

122922

Rev. 1.06

HC12

S0648106

N/A

L0082101

S0648106_PDA

S0648106

DEUTZ 2011L03 PERKINS

404C PERKINS 404D FORD EFI

2.5L FORD EFI

2.3L

- Add Tier 3 engines –Standardized on Jumper Configuration pins (J5,J6) for engines and models,  -Add low/high current propel pump option –Fixed footswitch issue when set to lockout –Fixed footswitch water ingress causing “Valve to low” fault.

15851

11.8.10

T110572

Rev. 1.00

164/TI

S0823100

ONLY FOR VIEWING UPGRADE TO S0823202

N/A

N/A

N/A

N/A

-          Initial Release software for ALC500 GenII PCB only

-          Added footswitch priority

 

16325

9.25.11

235321

Rev. 2.02

164/TI

S0823202

NA

NA

NA

NA

- Fixed issue with footswitch not forcing timeout when held on startup.
- Convert from prototype WebGPI library to 3.10 released library.
- Fix issue with incorrect run screen data due to ill placed comment in HTML.

- Fixed calibration issue - Boom stow/out of stow propel speed.
- Nuisance Fault GenII - Monitor added to detect floating ground.
- Corrected VBatt calculation.
- Kernel application layer changed to correct random changes to 60% current output.
- Fixed Drive Enable operation while transitioning through joystick neutral. (ecn11605b)

 

 

 

 

 

 

 

 

 

 

 

 

 

S60/65

9154

5.28.03

94772

Rev. 1.00

HC12

S0649100

N/A

L0082101

S0649100_PDA

S0649100

S0816201

 

 

 

DEUTZ 3CYL   FORD EFI   P404C    

Also installed on Pre-pro 1 #, Pre-pro 2 # .

9808

4.19.04

94772

Rev. 1.00

HC12

S0649100

N/A

L0082101

S0649100_PDA

S0649100

Tier II parameters filled in manually.

10326

8.30.04

106349

Rev. 1.01

HC12

S0649101

N/A

L0082101

S0649101 PDA

S0649101

Tier II engines, separate S60 to S60 2WD and S60 4WD, change Motor shift functions, Brake release when steer, brake off delay, rocker steer as a pin select option.

12272

9.26.05

110161

Rev. 1.02

HC12

S0649102

N/A

L0082101

S0649102 PDA

S0649102

-Corrected ramping rate on power up –Recall all default values when valid model selection jumpers are detected –Turntable ramping in/out Stowed- Update Run Boom Screen  - Separate CW ,CCW parameters, and Propel not stowed in Setup/Machine screen –Modified several default value –Modified joystick calibration values.

14045

8.15.06

110161

Rev. 1.03

HC12

S0649103

N/A

L0082101

S0649103_PDA

S0649103

DEUTZ 3CYL   FORD EFI   P404C     FORD EFI2.3L

Add new 2.3L Ford engine parameters

19607

6.23.08

110161

Rev. 1.03

HC12

S0649103

N/A

L0082101

S0649103_PDA

S0649103

Manually change Pulse/Rev of P404C engine from 8.9 to 10.6

 

20133

8.12.08

139499

Rev. 1.04

HC12

S0649104

N/A

L0082101

S0649104_PDA

S0649104

Ford EFI 2.5L

Perkins 404C

Ford EFI 2.3L

Deutz 2011L03

GM 3.0L

Perkins 404D

- Add Tier 3 engines –Standardized on Jumper Configuration pins (J5,J6) for engines and models,  -Add low/high current propel pump option –Fixed footswitch issue when set to lockout –Fixed footswitch water ingress causing “Valve to low” fault.

9154

 To

21000

11.17.10

T110561

Rev. 1.00

164/TI

S0816100

ONLY FOR VIEWING UPGRADE TO S0816201

N/A

N/A

N/A

N/A

-          Initial Release software for ALC500 GenII PCB only

-          Added footswitch priority

 

9154

To

21000

 

And

S60HC

9.19.11

235411

Rev. 2.01

164/TI

S0816201

NA

NA

NA

NA

- Fixed issue with footswitch not forcing timeout when held on startup.
- Fixed calibration issue - Boom stow/out of stow propel speed.
- Nuisance Fault GenII - Monitor added to detect floating ground.
- Corrected VBatt calculation.
- Kernel application layer changed to correct random changes to 60% current output.
- Fixed Drive Enable operation while transitioning through joystick neutral. (ecn11670b)

 

 

 

 

 

 

 

 

 

 

 

 

 

S60X/65

21001

05.25.10

139748

Rev. 1.00

164/TI

S0818100

ONLY FOR VIEWING UPGRADE TO S0818202

NA

NA

NA

S0818100

S0818202

Ford EFI 2.5L

Perkins 404C

Ford EFI 2.3L

Deutz 2011L03

GM 3.0L

Perkins 404D

Deutz 2011L04i

 

-          Initial Release software for ALC500 GenII PCB only

-          Add Deutz 2011L04 engine

-          Add Dual Capacity option

-          Add Angle sensor input

-          Add footswitch priority

-          Change Boom2 input joystick to Rocker Sw.

21489

03.17.11

T114160

Rev. 1.01

164/TI

S0818101

ONLY FOR VIEWING UPGRADE TO S0818202

NA

NA

NA

N/A

-          Corrected low voltage issue with Steer and added voltage check for valve power vs. ECU power

 

22666

9.19.11

235323

Rev. 2.02

164/TI

S0818202

NA

NA

NA

NA

- Fixed issue with footswitch not forcing timeout when held on startup.

- Convert from prototype WebGPI library to 3.10 released library.
- Added missing angle sensor screen to installer.

- Fixed calibration issue - Boom stow/out of stow propel speed.
- Nuisance Fault GenII - Monitor added to detect floating ground.
- Corrected VBatt calculation.
- Kernel application layer changed to correct random changes to 60% current output.
- Fixed - Cannot change the stow/out-of-stow values if not in that position.
- Fixed Drive Enable operation while transitioning through joystick neutral. (ecn11605b)

 

 

 

 

 

 

 

 

 

 

 

 

 

Z80

T-CON

101

5.16.02

88055

Rev. 1.00

167

S0555100

L0068317

L0060317

S0555100_PDA

S0555100

S0555102

 

Controls set up for prEN280 load sense.

 

 

94609

Rev. 1.01

167

S0555101

L0068317

L0060317

S0555101_PDA

S0555101

 

Improved leveling.  EN280 load sense, used in Europe. 

238

7.2.03

94946

Rev. 1.02

167

S0555102

L0068317

L0060317

S0555102_PDA

S0555102

 

Added one second delay to load sense. 

454

6.16.04

102410

Rev. 1.03

167

S0555103

L0068317

L0060317

S0555103_PDA

S2-TCON-0555103

 

Tier II and 12.5kW welder option.

928

5.16.06

111627

Rev. 1.04

167

S0555104

L0068317

L0060317

S0555104_PDA

S0555104

S0555104

 

Activate Dual Motion, change parameters, Hi/Low generator package

2501

 

 

 

 

 

 

 

 

 

 

 

11.30.09

146360

Rev. 1.05

167

S0555105

L0068317

L0060317

S0555105 PDA

S0555105

S0555105

 

Tier III engines DEUTZ 2011LO4i, PERKINS 804T, CONTINENTAL TME27

Steer hunting corrected

Footswitch Priority

GHG10 Generator added

Prox Kill and Load Sense function separated

Deutz oil PSI shutdown 22psi

Fixed Generator 2 spd motor stroke

2511

1/5/10

146392

Rev. 2.00

167

S0814200

L0068317

L0060317

N/A

N/A

S0814200

 

Hardware change, cannot use on older machines

Safety limit switch monitoring

Removed Tier II engine

Second window added before resetting all defaults

Load sense system has input to TCON for redundancy

Europe/USA antistall option added

Plat Level  threshold auto calibration

Z80

P-CON

101

5.16.02

88052

Rev. 1.00

HC08A

S0556100

L0087100

L0099101

S0556100_PDA

S0556100

S0556102

 

prEN280 load sense

 

 

94610

Rev. 1.01

HC08A

S0556101

L0087100

L0099102

S0556101_PDA

S0556101

 

Improved leveling.  EN280 load sense, used in Europe. 

238

7.2.03

94947

Rev. 1.02

HC08A

S0556102

L0087100

L0099102

S0556102_PDA

S0556102

 

Added one second delay to load sense. 

928

5.16.06

111628

Rev. 1.04

HC08A

S0556104

L0087100

L0099102

S0556104_PDA

S0556104

S0556104

 

Activate Dual Motion, change parameters, Hi/Low generator package

2501

11.30.09

146358

Rev. 1.05

HC08A

S0556105

L0087100

L0099102

S0556105 PDA

S0556105

S0556105

 

Same as TCON S0555105

 

2511

1/5/10

146394

Rev. 2.00

HC08A

S0815200

L0087100

L0099102

N/A

N/A

S0815200

 

Must be used with TCON version 2.00

Safety limit switch monitoring

Removed Tier II engine

Second window added before resetting all defaults

Load sense system has input to TCON for redundancy

Europe/USA antistall option added

Plat Level  threshold auto calibration

Z80

D-CON

101

5.16.02

50154

Rev. 1.01

HC08

S0279101

L0069000

L0047304

N/A

N/A

S0279101

 

Release software

 

 

50154

Rev. 1.02

HC08A

S0613102

L0087100

L0090400

N/A

N/A

S0613102

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z135

T-CON

101

3.30.05

101002

Rev. 1.00

167

S0675100

ONLY FOR VIEWING UPGRADE TO S0675202

L0068317

L0113100

N/A

N/A

S0675202

Work with:  

S0677200

S0676201

S0681100

Release software

471

1.02.07

101002

Rev. 1.11

 

S0675111

ONLY FOR VIEWING UPGRADE TO S0675202

N/A

N./A

See CD part number 119801 for installation instruction for software and hardware.  The software fixes the following problems:

·         Duetz engine temperature shutdown changed from 248 deg F to 275 deg F

·         Corrected recovery circuit  to lower  the platform to ground

·         Disable steer mode change while driving not works.

·         Added three level password to SCON.

·         Use aux hyd pump to get out of platform overload conditions

·         the boom cannot be operated with the SCON uncalibrated

·         Improved error message handling

·         Eliminated the P12 axle fault message.

·         Eliminated pre and post leveling

Backward compatible only if update hardware LSP1RO and software V1.10 on P-CON and S-CON.

 

 

1154

12/31/09

139645

Rev. 2.00

167

S0675200

ONLY FOR VIEWING UPGRADE TO S0675202

L0068317

L0113100

N/A

N/A

S0675202

Work with:  

S0677200

S0676201

S0681100

Must be used with SCON version 2.00 and PCON version 2.00

Tier III engine added

Deutz low oil psi changed to 22

LSS1RS/LSS1RO monitoring

Platform Leveling parameters

GHG10 gen added

Load sense and prox kill function separated

Error history resolution changed from 1 to 0,01

PBMAO screen locked

1571

9.20.11

227202

Rev. 2.02

167

S0675202

L0068317

L0113100

NA

NA

Must be used with SCON version 2.00 and PCON version 2.01

1. Modified engine state machine to only allow high idle 3 seconds after starting engine.
2. Alarms added for engine faults: oil, temperature, and tach.
3. Engine start is no longer allowed during self test.
4. Modifications to Autoshift function.
5. Allow Rabbit or Turtle selection in service bypass mode.
6. Steering is now disabled during ProxKill and Overload conditions.
7. Alarms added for axle and steer angle sensor faults.
8. Alarms added for all joystick faults.
9. Alarms added for all valve faults.
10. Added function disables for Platform Rotate, Jib Ext/Ret, Steer, Brake and Axle functions with valve faults present.
11. Fixed the issue of high current pump setting.
12. Added missing field in language strings for propel.
13. Added Force Neutral for Jib Ext/Ret and Platform Rotate from fault recovery.
14. Changed Axle input default settings.
15. Modified Boom2 to ignore LSS interlock faults if the boom is in the rampdown or lowered state.
16. Added stowed state and stowed bypass condition to LSS Interlock to prevent motions from being disabled when hydraulics relax with the boom stowed.
17. Changes to LSS Interlock function to prevent nuisance faults.
18. Modifications to Engine state machine to better support Deutz engines.
19. Added level 3 alarm for propel flow valves.
20. Modifications to common display.
21. Changes to machine defaults.

???

???

237071

Rev. 3.00

167

S0827300

L0068317

L0113100

NA

NA

S0827300

Work with:  

S0829300

S0828301

S0681300

- Alarms added for P7R, P6R1 and P6R2 faults.
- Alarm added for primary boom switches fault.
- Added Not Calibrated text display for primary or secondary boom safety angle sensor not calibrated.
- Fixed the misplaced setting between Adjust Jib Up Speed Retracted and Jib Up/Down Ramp Decel Rate.
- Fixed the misplaced setting between Adjust Turntable Rotate Speed Retracted and Turntable Rotate Speed Extended.
- Two seconds off delay added when Axle is fully extended or retracted.
- Three seconds delay added for clearing error history or other memory writing.
- Added jib up/down joystick calibration reset to TCON display menu.
- Modications to screen text strings in English and their translation in 7 other languages.

 

 

 

 

 

 

 

 

 

 

 

 

 

Z135    P-CON

 

101

3.30.05

101003

Rev. 1.00

HCS12

S0676100

ONLY FOR VIEWING UPGRADE TO S0676201

N/A

L0123101

N/A

N/A

S0676201

Work with:  

S0675202

S0677200

 S0681300

Release software

101

8.03.05

101003

Rev. 1.00

HCS12

 

N/A

L0123102

N/A

N/A

Update

471

1.02.07

101003

Rev. 1.10

HCS12

S0676110

ONLY FOR VIEWING UPGRADE TO S0676201

N/A

N/A

N/A

See Z135 T-CON comment

1154

12/31/09

139646

Rev. 2.00

HCS12

S0676200

ONLY FOR VIEWING UPGRADE TO S0676201

N/A

N/A

N/A

See Z135 T-CON comment

1571

9.20.11

227203

Rev. 2.01

HCS12

S0676201

NA

L0123103

NA

NA

Must use TCON version 2.02 and SCON 2.00

- Jib U/D valve Fault Detect Current to 370mA from 850 mA

- Do not clear valve status if already in error.

???

??

237072

Rev. 3.01

HCS12

S0828301

NA

L123104

NA

NA

S0828301

Work with:  

S0829300

S0827300

   S0681100

- Modifications to load sense function.

 

 

 

 

 

 

 

 

 

 

 

 

 

Z135    S-CON

101

3.30.05

94978

Rev. 1.00

HCS12

S0677100

ONLY FOR VIEWING UPGRADE TO S0677200

N/A

L0125101

N/A

N/A

S0677200

Work with:  

S0675202

S0676201

 S0681100

Release software

471

1.02.07

94978

Rev. 1.10

HCS12

S0677110

ONLY FOR VIEWING UPGRADE TO S0677200

N/A

N/A

N/A

See Z135 T-CON comment

1154

12/31/09

139647

Rev. 2.00

HCS12

S0677200

N/A

N/A

N/A

See Z135 T-CON comment

??

??

237073

Rev. 3.00

HCS12

S0829300

NA

L0125101

NA

NA

S0829300

Work with:  

S0828301

S0827300

S0681100

- Modifications to load sense function.
- Added CAN message for primary or secondary boom safety angle sensor not calibrated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z135

D-CON

101

3.30.05

101004

Rev. 1.00

HC08A

S0681100

L0087100

L0091100

N/A

N/A

 

 

Release software

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

SER. #

Inc. Date

Hardware Assembly Part #

Software Revision

Microcontroller

Type

PC Install Program (.exe)

Boot File (.hex Need before Kernel File Download)

Kernel File (.hex)

PDA xml File (view/adjust program on board with PDA)

WebGPI PDA Application File (.hex)

Backward compatible

Applicable Engines

Comments

S100/ S120 T-CON

101/ 103

4.21.00/ 6.20.00

*50153

Rev. 1.01

167

S0277101

L0068303

L0060303

N/A

N/A

S0277101

 

* Assembled box with board installed. Replace with S0277108.  prEN280 load sense. 

131/ 313

 

*50153

Rev. 1.08

167

S0277108

L0068304

L0060304

N/A

N/A

S0277108

 

* Assembled box with board installed. Improved platform leveling and calibration screens.  prEN280 load sense

186 / 799

6.6.03

*50153

Rev. 1.10

167

S0277110

L0068304

L0060304

N/A

N/A

S0277110

 

* Assembled box with board installed. Removed engine over speed diagnostics. Added one second delay to load sense.  EN280 load sense

253/ 1018

4.05.04

102696

Rev. 1.11

167

S0277111

L0068304

L0060304

N/A

N/A

S0277111

 

Tier II and 12.5kW welder option.

253/ 1029

12.07.04

102730

Rev. 2.00

167

S0716200

 

L0068304

 

L0060304

 

N/A

N/A

S0716212

 

Low current drive pump output instead of the high current output. 

757/2667

6.15.09

146135

Rev. 2.10

167

S0716210

L0068304

 

L0060304

 

N/A

N/A

Added Tier III engines: Cummins B3.3T, Deutz 2011L04i, and Perkins 804T.  Added Chassis Tilt Cutout, GHG10 Generator, and High Current Drive Pump functionality.  See SMS p/n 146136 Rev A for more info/revisions.

796/2693

11.04.09

146135

Rev. 2.11

167

S0716211

L0068304

 

L0060304

 

N/A

N/A

Fixed bug in Boom Configuration screen, added Footswitch Priority. See SMS p/n 146136 Rev B for more info/revisions.

SERV

4.06.10

146135

Rev. 2.12

167

S0716212

L0068304

 

L0060304

 

N/A

N/A

Fixed Steering bug.  See SMS p/n 146136 Rev C for more info.

806/2710

1.19.10

146387

Rev. 3.00

167

S0812300

L0068304

 

L0060304

 

N/A

N/A

S0812312

Cummins B3.3T, Deutz 2011L04i, and Perkins 804T

Hardware change, cannot use on older machines.  Added Safety limit switch monitoring and removed Tier II engines.  Second window added before resetting all defaults.  Load sense system now has input to TCON for redundancy.  Added Europe/USA antistall options.  See SMS p/n 146388 Rev A for more info/revisions.

877 / 2907

11.29.10

T109426

Rev. 3.10

167

S0812310

L0068304

 

L0060304

 

N/A

N/A

Added Shipyard Boom models S3200 and S3800.  Added Numeric Fault Code display option and Autoshift functionality, restored Propel Upshift/Downshift Ramping, split Boom Up/Down Speed Limits.  See SMS p/n T109428 Rev A for more info/revisions.

894 / 3012

3.30.11

T109426

Rev.

3.11

167

S0812311

L0068304

 

L0060304

 

N/A

N/A

Added steering “fix”-once joystick is released. Wheel(s) will attempt to reach set point three times then stop until the next steering command is issued. See SMS p/n T109428 Rev B for more info/revisions.

?

?

T109426

Rev.

3.12

167

S0812312

L0068304

 

L0060304

 

N/A

N/A

Use with PCON software S0813300.

Solved the problem of safety trip at Boom angle >= 53 degrees and boom length = 100.

Updated strings and their translation.

Modification to the default parameters.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S3200/ S3800

101D/

101D

3.30.11

T109426

Rev 3.11

167

S0812311

L0068304

 

L0060304

 

N/A

N/A

S0812312

Cummins B3.3T, Deutz 2011L04i, and Perkins 804T

Added steering “fix”-once joystick is released. Wheel(s) will attempt to reach set point three times then stop until the next steering command is issued. See SMS p/n T109428 Rev B for more info/revisions.

?

?

T109426

Rev.

3.12

167

S0812312

L0068304

 

L0060304

 

N/A

N/A

Use with PCON software S0813300.

Solved the problem of safety trip at Boom angle >= 53 degrees and boom length = 100.

Updated strings and their translation.

Modification to the default parameters.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S100/ S120  P-CON

101/ 103

4.21.00/ 6.20.00

62383

Rev. 1.01

HC08

S0278101

L0069000

L0048305

N/A

N/A

S0278101

 

Replace with S0278108.  prEN280 load sense

131/ 313

 

62383

Rev. 1.08

HC08

S0278108

L0069000

L0048310

N/A

N/A

S0278108

 

Improved platform leveling and calibration screens.  prEN280 load sense

 

6.6.03

62383

Rev. 1.10

HC08

S0278110

L0069000

L0048310

N/A

N/A

S0278110

 

Added one second delay to load sense.  EN280 load sense

 

 

62383

Rev. 1.08

HC08A

S0612108

L0087100

L0089400

N/A

N/A

S0612210

 

Same software function as S0278108 except used with HC08A microcontroller.  prEN280 load sense

186 / 799

6.6.03

62383

Rev. 1.10

HC08A

S0612110

L0087100

L0089400

N/A

N/A

 

Same software function as S0278110 except used with HC08A microcontroller.  EN280 load sense

757/2667

6.15.09

146138

Rev. 2.10

HC08A

S0612210

L0087100

L0089400

N/A

N/A

 

Numerous bug fixes

806/2710

1.19.10

146390

Rev. 3.00

HC08A

S0813300

L0087100

L0089400

N/A

N/A

S0813300

 

Revised Load Sense System – Added additional signal (to TCON) and cross-checking between TCON/PCON.

 

 

 

 

 

 

 

 

 

 

 

 

 

S100/ S120 D-CON

101/ 103

4.21.00/ 6.20.00

50154

Rev. 1.01

HC08

S0279101

L0069000

L0047304

N/A

N/A

S0279101

 

 

 

 

50154

Rev. 1.02

HC08A

S0613102

L0087100

L0090400

N/A

N/A

S0613102

 

Same functions as S0279101 software except used on HC08A microcontroller.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

SER. #

Inc. Date

Hardware Assembly Part #

Software Revision

Microcontroller

Type

Compiled Control Program File Plus1 (*.lhx) Zapi (*.h86)

Backward Compatible

Service & Diagnostic Application File {for adjusting parameters and troubleshooting} (*.p1d)

Adjustable Parameter Default Value File

(*.xml)

Comments

Z40
TCON

104

04.04.07

110989

Rev. A

Plus1

110985A

 

128571A

 

Only for use with Rev. A TCON/PCON software.
(Note:
Software download procedure similar to S60HC, see links below)

133

07.12.07

Rev. B

110985B

110985D

Requires Rev B AC Motor Controller Software
Z40 Rev B to Rev C Upgrade Info |  Z40 Rev A to Rev C Upgrade Info

425

01.21.08

Rev. C

110985C

1275

07.06.11

Rev. D

110985D

230797A

Requires 230797A service tool to view Z40 Rev D diagnostics. Obtaining Plus+1 Service and Diagnostic Tool

| Z40 Rev C to Rev D Upgrade Info

Z40

PCON

104

04.04.07

110990

Rev. A

Plus1

110986A

 

Same as TCON

 

Only for use with Rev. A TCON/PCON software.
(Note:
Software download procedure similar to S60HC, see links below)

133

07.12.07

Rev. B

110986B

110986D

Requires Rev B AC Motor Controller Software
Z40 Rev B to Rev C Upgrade Info |  Z40 Rev A to Rev C Upgrade Info

425

01.21.08

Rev. C

110986C

1275

07.06.11

Rev. D

110986D

230797A

Requires 230797A service tool to view Z40 Rev D diagnostics. Obtaining Plus+1 Service and Diagnostic Tool | Z40 Rev C to Rev D Upgrade Info

Z40 AC Master

104

04.04.07

110665

Rev 16

Zapi

 

128053A

 

 

 

Use only with Rev A  TCON/PCON Software

133

07.12.07

 

Rev. B

128053B

 

 

 

Use only with Rev B, Rev C  or Rev D TCON/PCON Software

Z40 AC

Slave

104

04.04.07

110665

Rev 16

Zapi

 

128054A

 

 

 

Use only with Rev A  TCON/PCON Software

133

07.12.07

 

Rev. B

128054B

 

 

 

Use only with Rev B, Rev C  or Rev D TCON/PCON Software

 

 

 

 

 

 

 

 

 

 

 

S60HC

TCON

13801

06.05.06

110991

Rev. A

Plus1

110987A

110987C

119607

 

Obtaining Plus+1 Service and Diagnostic Tool

Connecting to Plus+1 on S60HC

Updating Plus+1 Software on S60HC

14191

08.24.06

Rev. B

110987B

 

18669

01.21.08

Rev. C

110987C

 

19039

04.21.08

Rev. A

139303A

139303B

 

20305

12.02.08

Rev. B

139303B

 

 

S60HC

SCON

13801

06.05.06

110992

Rev. A

Plus1

110988A

110988C

Same as TCON

 

 

14191

08.24.06

Rev. B

110988B

 

 

18669

01.21.08

Rev. C

110988C

 

 

19039

04.21.08

Rev. A

139304A

139304B

 

Requires different string sensor, harness update and add’l relay in ground box

20305

12.02.08

Rev. B

139304B

 

 

 

Model

Serial

Inc. Date

PCON Hardware PN

GCON Hardware PN

Microcontroller type

Software Revision

Software PN

Backwards compatible

Comments

GR

GR11-20000

06/01/2011

137633

137692

SmartLinkTM

 

 

137641B.gff

137641C.gff

 

Initial Release

GR11-20866

09/13/2011

137633

137692

SmartLinkTM

 

 

137641C.gff

Eliminates F035 nuisance error.  Allows for descent delay to be turned off for AUS GS1532 and GS1932

QS

 

QS11-1000

06/01/2011

137633

137692

SmartLinkTM

 

 

137641C.gff

137641C.gff

 

Initial Release

QS11-1016

09/13/2011

137633

137692

SmartLinkTM

 

 

137641C.gff

Eliminates F035 nuisance error.  Allows for descent delay to be turned off for AUS GS1532 and GS1932

 

 

 

 

 

 

 

 

 

 

GRC

GRC-1000

06/01/2011

137633

137692

SmartLinkTM

 

 

137641C.gff

137641C.gff

 

Initial Release

GRC-1100

09/13/2011

137633

137692

SmartLinkTM

 

 

137641C.gff

Eliminates F035 nuisance error.  Allows for descent delay to be turned off for AUS GS1532 and GS1932

 

 

 

 

 

 

 

 

 

 

GS-1530

GS30A-110000

06/01/2011

137633

137692

SmartLinkTM

 

 

137641C.gff

137641C.gff

 

Initial Release

GS30A-111106

09/13/2011

137633

137692

SmartLinkTM

 

 

137641C.gff

Eliminates F035 nuisance error.  Allows for descent delay to be turned off for AUS GS1532 and GS1932

GS30C-10000

09/13/2011

137633

137692

SmartLinkTM

 

 

137641C.gff

137641C.gff

Initial Release on Coventry machines

 

 

 

 


WebGPI Application Install Program Procedures

ALC-500

 

S0513100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S80/85 with the ALC-500 control board P/N 81542, serial numbers 3082 through 3423. 

 

1.      Click on the file link HERE (Install S0513100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0513100PDA.xml). 

 

S0513200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application was used on Z60/34 with the ALC-500 control board P/N 89353, serial numbers after 4000.  This software is obsolete and should be upgraded to S0513222 if found installed on a machine. 

 

1.      Click on the file link HERE (Install S0513200.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0513200_PDA.xml). 

NOTE:            Control boards with this software should be upgraded to S0513222. 

 


S0513204.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application was used on: ALC-500 control board P/N 89353 machines S80/85 with serial numbers 3424 through 3486, Z45/25 serial numbers 21180 through 21563, and Z60/34 serial numbers 4001 through 4168. 

 

1.      Click on the file link HERE (Install S0513204.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 89353 S80/85, Z60, or Z45 control boards. 

9.      For PDA interface to the control card, click HERE (S0513204_PDA.xml).

 

NOTE:            If the machine has been switching models to Z45 Narrow (Z60 machines unable to drive) the board with this software should be upgraded to S0513222. 

 

S0513222.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80/85 with the ALC-500 control board P/N 89353, serial numbers 3486 through 4075; Z45/25 with the ALC-500 control board P/N 89353, serial numbers 21563 through 22050; and Z60/34 with the ALC-500 control board P/N 89353, serial numbers 4168 through 4550.

 

1.      Click on the file link HERE (Install S0513222.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 89353 control board. 

9.      For PDA interface to the control card, click HERE (S0513222_PDA.xml).

 

 

S0690100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z60/34 with the ALC-500 control board P/N 102750, serial numbers after 4550.

 

1.      Click on the file link HERE (Install S0690100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0690100_PDA.xml).

 

S0648101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.  

 

This application is used on: S40/45 with the ALC-500 control board assembly P/N 94771, serial numbers 7000 through 7568. 

 

1.      Click on the file link HERE (Install S0648101.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0648101_PDA.xml).

 

S0648102.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S40/45 with the ALC-500 control board assembly P/N 102259, serial numbers after 7568. 

 

1.      Click on the file link HERE (Install S0648102.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0648102_PDA.xml).

 

S0648105.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S40/45 with the ALC-500 control board assembly P/N 102259, serial numbers after 11189. 

 

1.      Click on the file link HERE (Install S0648105.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0648105_PDA.xml).

 

S0648106.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S40/45 with the ALC-500 control board assembly P/N 122922, serial numbers after 15581. 

 

1.      Click on the file link HERE (Install S0648106.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0648106_PDA.xml).

 

S0823100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S40/45 with the ALC-500 Gen II control board assembly P/N T110572 after serial number 15850.

 

1.      Click on the file link HERE (Install S0823100.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

 

 

S0823202.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S40/45 with the ALC-500 Gen II control board assembly P/N 235321.

 

1.      Click on the file link HERE (Install S0823202.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board.

 

S0649100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 control board assembly P/N 94772, after serial numbers 9153. 

 

1.      Click on the file link HERE (Install S0649100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0649100_PDA.xml).

 

S0649101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 control board assembly P/N 106349, serial numbers after 9153. 

 

1.      Click on the file link HERE (Install S0649101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

For PDA interface to the control card, click HERE (S0649101_PDA.xml).

 

S0649102.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 control board assembly P/N 110161 after serial number 9807.

 

1.      Click on the file link HERE (Install S0649102.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0649102_PDA.xml).

 

S0649103.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 control board assembly P/N 110161 after serial number 14045.

 

1.      Click on the file link HERE (Install S0649103.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0649103_PDA.xml).

 

S0649104.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 control board assembly P/N 110161 after serial number 14045.

 

1.      Click on the file link HERE (Install S0649104.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0649104_PDA.xml).

 

S0816100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N T110561.

 

1.      Click on the file link HERE (Install S0816100.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.

 

S0816201.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N 235411.

 

1.      Click on the file link HERE (Install S0816201.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

 

S0662100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z45/Z45 Narrow with the ALC-500 control board assembly P/N 94773, serial numbers 22050 through 23384.

 

1.      Click on the file link HERE (Install S0662100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (Install S0662100_PDA.xml).

 

S0662101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z45/Z45 Narrow with the ALC-500 control board assembly P/N 106348, serial numbers after 23385. 

 

1.      Click on the file link HERE (Install S0662101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (Install S0662101_PDA.xml).

 

S0662103.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z45/Z45N with the ALC-500 control board assembly P/N 110164 after serial number 26999.

 

1.      Click on the file link HERE (Install S0662103.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0662103_PDA.xml).

 

S0662104.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on:     Z45/Z45N with the ALC-500 control board assembly P/N 110164 after serial number 30142.

                                                Z45M with the ALC-500 control board assembly P/N 110164 after serial number 100.

                                               

1.      Click on the file link HERE (Install S0662104.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0662104PDA.xml).

 

S0662106.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on:     Z45/Z45N with the ALC-500 control board assembly P/N 139502 after serial number 38511.

                                                Z45M with the ALC-500 control board assembly P/N 139502 after serial number 1423.

 

1.      Click on the file link HERE (Install S0662106.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0662106PDA.xml).

 

S0824100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on:     Z45/Z45N with the ALC-500 Gen II control board assembly P/N T110562.

                                                Z45M with the ALC-500 control board assembly P/N T110562.

 

1.      Click on the file link HERE (Install S0824100.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.

 

S0824200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on:     Z45/Z45N with the ALC-500 Gen II control board assembly P/N 235473.

                                                Z45M with the ALC-500 control board assembly P/N 235473.

 

1.      Click on the file link HERE (Install S0824200.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board.

 

S0690101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z60/34 with the ALC-500 control board assembly P/N 102750 after serial number 6107.

 

1.      Click on the file link HERE (Install S0690101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0690101_PDA.xml).

 

S0690102.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z60/34 with the ALC-500 control board assembly P/N 102750 after serial number 6388.

 

1.      Click on the file link HERE (Install S0690102.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0690102_PDA.xml).

 

S0690103.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z60/34 with the ALC-500 control board assembly P/N 122924 after serial number 9699.

 

1.      Click on the file link HERE (Install S0690103.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0690103_PDA.xml).

 

S0825100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z60/34 with the ALC-500 Gen II control board assembly P/N T110571 after serial number 10178.

 

1.      Click on the file link HERE (Install S0825100.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.

 

S0825200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z60/34 with the ALC-500 Gen II control board assembly P/N T110571 after serial number 10178.

 

1.      Click on the file link HERE (Install S0825200.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board.

 

S0717100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z51M with the ALC-500 control board assembly P/N 110157 after serial number 100.

 

1.      Click on the file link HERE (Install S0717100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0717100_PDA.xml).

 

S0717102.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z51M with the ALC-500 control board assembly P/N 139505 after serial number 503.

 

1.      Click on the file link HERE (Install S0717102.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0717102_PDA.xml).

 

S0826100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z51M with the ALC-500 Gen II control board assembly P/N T110563 after serial number xxxxx.

 

1.      Click on the file link HERE (Install S0826100.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.

 

S0826200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: Z51M with the ALC-500 Gen II control board assembly P/N T110563 after serial number xxxxx.

 

1.      Click on the file link HERE (Install S0826200.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board.

 

S0718100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80/85 with the ALC-500 control board assembly P/N 102625 after serial number 4075.

 

1.      Click on the file link HERE (Install S0718100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0718100_PDA.xml).


S0718101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80/85 with the ALC-500 control board assembly P/N 122271 after serial number 5861.

 

1.      Click on the file link HERE (Install S0718101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0718101_PDA.xml).

 

S0718102.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80/85 with the ALC-500 control board assembly P/N 122271 after serial number 5897.

 

1.      Click on the file link HERE (Install S0718102.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0718102_PDA.xml).

 

S0718103.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80/85 with the ALC-500 control board assembly P/N 122731 after serial number 7139.

 

1.      Click on the file link HERE (Install S0718103.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0718103_PDA.xml).

 

S0821100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80 with the ALC-500 Gen II control board assembly P/N T110570 for Service Parts.

 

1.      Click on the file link HERE (Install S0821100.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure ALC500 Gen II to interface the control board. 

9.      The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.

 

S0821201.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80 with the ALC-500 Gen II control board assembly P/N 235403 for Service Parts.

 

1.      Click on the file link HERE (Install S0821201.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure ALC500 Gen II to interface the control board. 

9.      The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.

 

S0780100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80/85-2008 with the ALC-500 control board assembly P/N 121457 after serial number 8000.

 

1.      Click on the file link HERE (Install S0780100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      For PDA interface to the control card, click HERE (S0780100_PDA.xml).

 

S0819100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80-2008 with the ALC-500 Gen II control board assembly P/N 139745 after serial number 8500.

 

1.      Click on the file link HERE (Install S0819100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.

 

S0819101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80-2008 with the ALC-500 Gen II control board assembly P/N T115457.

 

1.      Click on the file link HERE (Install S0819101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

9.      The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.

 

S0819202.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S80-2008 with the ALC-500 Gen II control board assembly P/N 235322.

 

1.      Click on the file link HERE (Install S0819202.exe).  

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board.

 

S0818100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N 138748 after serial number 21000.

 

1.      Click on the file link HERE (Install S0818100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Typical and click Next.

7.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

 

S0818101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N T114160.

 

1.      Click on the file link HERE (Install S0818101.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Typical and click Next.

7.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board. 

 

S0818202.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N 235323.

 

1.      Click on the file link HERE (Install S0818202.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Typical and click Next.

7.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the control board.

 

ALC1000 / S1XX

 

S0277101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N 50153, serial numbers 101/103 through 130/312 (some machines have been upgraded to S0277108).  Machines with this software should be upgraded to S0277108 software (P-CON needs to be upgraded to S0278108 software at the same time). 

 

1.      Click on the file link HERE (Install S0277101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 50153 S100/120 T-CON control board assembly. 

 

S0277108.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N 50153, machines after serial numbers 131/313 through 185/798. 

 

1.      Click on the file link HERE (Install S0277108.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 50153 S100/120 T-CON control board assembly. 

 

S0277110.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N 50153, machines after serial number 185/798 through 252/1017. 

 

1.      Click on the file link HERE (Install S0277110.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 50153 S100/120 T-CON control board assembly. 

 

S0277111.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N 102696, machines after serial number 253/1018. 

 

1.      Click on the file link HERE (Install S0277111.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 102696 S100/120 T-CON control board assembly. 

 

S0716200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N 102730, machines after serial number 253/1029. 

 

1.      Click on the file link HERE (Install S0716200.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 102730 S100/120 T-CON control board assembly. 

 

S0716210.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N 146135, machines after serial number 756/2666. 

 

1.      Click on the file link HERE (Install S0716210.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146135 S100/120 T-CON control board assembly. 

 

S0716211.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N 146135, machines after serial number 795/2692. 

 

1.      Click on the file link HERE (Install S0716211.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146135 S100/120 T-CON control board assembly. 

 

S0716212.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N 146135, (Post-production Service release, see Matrix for backwards compatibility) 

 

1.      Click on the file link HERE (Install S0716212.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146135 S100/120 T-CON control board assembly. 

 

S0812300.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N 146387, machines after serial number 805/2709.

 

1.      Click on the file link HERE (Install S0812300.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146387 S100/120 T-CON control board assembly. 

 

S0812310.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N T109424, machines after serial number 877/2907.

 

1.      Click on the file link HERE (Install S0812310.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the T109426 S100/120 T-CON control board assembly. 

 

S0812311.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N T109424, machines after serial number 894/3012.

This application is used on S3200/S3800 T-CON control box assembly P/N T109424, machines after serial number 101D/101D.

 

1.      Click on the file link HERE (Install S0812311.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the T109426 S100/120 T-CON control board assembly. 

 

S0812312.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 T-CON control box assembly P/N T109424.

This application is used on S3200/S3800 T-CON control box assembly P/N T109424.

 

1.      Click on the file link HERE (Install S0812312.exe).

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the T109426 S100/120 T-CON control board assembly. 

 

S0278101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 P-CON control box assembly P/N 62383, serial numbers 101/103 through 130/312 (some machines have been upgraded to S0277108).  Machines with this software should be upgraded to S0278108 software (T-CON needs to be upgraded to S0277108 software at the same time). 

 

1.      Click on the file link HERE (Install S0278101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 50153 S100/S120 P-CON control board assembly. 

 

S0278108.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/S120 P-CON control box assembly P/N 62383, machine serial numbers 131/313 through 188/798. 

 

1.      Click on the file link HERE (Install S0278108.exe)

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 62383 S100/120 P-CON control board assembly. 

 

S0278110.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on some S100/S120 P-CON control box assembly P/N 62383, machine serial numbers 131/313 through 188/798. 

 

1.      Click on the file link HERE (Install S0278110.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 62383 S100/120 P-CON control board assembly. 

 

S0279101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 and S100/120 D-CON control board assembly P/N 50154, serial numbers 101 and 101/103 respectively. 

 

1.      Click on the file link HERE (Install S0279101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 50154 Z80 and S100/120 D-CON control board assembly. 

 

S0555100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 T-CON control board assembly P/N 88055, serial numbers 101 through current production machines (some machines have been upgraded to S0555101). 

 

1.      Click on the file link HERE (Install S0555100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 88055 Z80 control board assembly. 

9.      For PDA interface to the control card, click HERE (Install S0555100PDA.xml).

 

S0555101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 T-CON control board assembly P/N 94609, serial numbers 101 through current production machines (some machines have been upgraded to S0555101). 

 

1.      Click on the file link HERE (Install S0555101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 94609 Z80 control board assembly. 

9.      For PDA interface to the control card, click HERE (Install S0555101-PDA.xml). 

 

S0555102.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 T-CON control board assembly P/N 94946, serial numbers 101 through current production machines (some machines have been upgraded to S0555101). 

 

1.      Click on the file link HERE (Install S0555102.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 94946 Z80 control board assembly.

9.      For PDA interface to the control card, click HERE (Install S0555102-PDA.xml). 

 

S0555103.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 T-CON control board assembly P/N 102410, serial numbers after 454. 

 

1.      Click on the file link HERE (Install S0555103.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 94946 Z80 control board assembly.

9.      For PDA interface to the control card, click HERE (Install S0555103-PDA.xml). 

 

S0555104.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 T-CON control board assembly P/N 102410, serial numbers after 928. 

 

1.      Click on the file link HERE (Install S0555104.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 94946 Z80 control board assembly.

9.      For PDA interface to the control card, click HERE (Install S0555104-PDA.xml). 

 

S0555105.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 T-CON control board assembly P/N 146360, serial numbers after 2501. 

 

1.      Click on the file link HERE (Install S0555105.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146360 Z80 control board assembly.

9.      For PDA interface to the control card, click HERE (Install S0555105-PDA.xml). 

 

S0814200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 T-CON control board assembly P/N 146392, serial numbers after 2511. 

 

1.      Click on the file link HERE (Install S0814200.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146392 Z80 control board assembly.

9.      PDA interface is no longer available

 

S0556100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 P-CON control board assembly P/N 88052, serial numbers 101/ 237 (some machines have been upgraded to S0556101). 

 

1.      Click on the file link HERE (Install S0556100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 88052 Z80 control board assembly. 

9.      For PDA interface to the control card, click HERE (Install S0556100_PDA.xml).

 

S0556101.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 P-CON control board assembly P/N 94610, serial numbers 101 through current production machines (some machines have been upgraded to S0556101). 

 

1.      Click on the file link HERE (Install S0556101.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 94610 Z80 control board assembly. 

9.      For PDA interface to the control card, click HERE (Install S0556101_PDA.xml).

 

S0556102.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 P-CON control board assembly P/N 94947, serial numbers 101 through current production machines (some machines have been upgraded to S0556101). 

 

1.      Click on the file link HERE (Install S0556102.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 94947 Z80 control board assembly. 

9.      For PDA interface to the control card, click HERE (Install S0556102_PDA.xml).

 

S0556104.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 P-CON control board assembly P/N 111628, serial numbers 928. 

 

1.      Click on the file link HERE (Install S0556104.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 111628 Z80 control board assembly. 

9.      For PDA interface to the control card, click HERE (Install S0556104_PDA.xml).

 

S0556105.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 P-CON control board assembly P/N 146358, serial numbers 2501. 

 

1.      Click on the file link HERE (Install S0556105.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146358 Z80 control board assembly. 

9.      For PDA interface to the control card, click HERE (Install S0556105_PDA.xml).

 

S0815200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 T-CON control board assembly P/N 146394, serial numbers after 2511. 

 

1.      Click on the file link HERE (Install S0815200.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146394 Z80 control board assembly.

9.      PDA interface is no longer available

 

S0612108.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/120 P-CON control board assembly P/N 62383, serial numbers through 185/798 (some machines have been upgraded to S0556101). 

 

1.      Click on the file link HERE (Install S0612108.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 62383 Z80 control board assembly. 

 

S0612110.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/120 P-CON control board assembly P/N 62383, serial numbers after 185/798 (some machines have been upgraded to S0556101). 

 

1.      Click on the file link HERE (Install S0612110.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 62383 S100/120 P-CON control board assembly. 

 

S0612210.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/120 P-CON control board assembly P/N 146138, serial numbers after 756/2666.

 

1.      Click on the file link HERE (Install S0612210.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146138 S100/120 P-CON control board assembly. 

 

S0813300.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on S100/120 P-CON control board assembly P/N 146390, serial numbers after 805/2709.

 

1.      Click on the file link HERE (Install S0813300.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 146390 S100/120 P-CON control board assembly. 

 

S0613102.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z80 and S100/120 D-CON control board assembly P/N 50154, serial numbers after 101/103. 

 

1.      Click on the file link HERE (Install S0613102.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 50154 Z80 and S100/120 control board assembly.

 

S0675100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 T-CON control board assembly P/N 101002, serial numbers 101 and after. 

 

1.      Click on the file link HERE (Install S0675100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 101002 Z135 T-CON control board assembly. 

 

S0675111.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 T-CON control board assembly P/N 119789. 

 

1.      Click on the file link HERE (Install S0675111.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 119789 Z135 T-CON control board assembly.

 

S0675200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 T-CON control board assembly P/N 139645. 

 

1.      Click on the file link HERE (Install S0675200.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 139645 Z135 T-CON control board assembly.

 

S0675202.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 T-CON control board assembly P/N 227202. 

 

1.      Click on the file link HERE (Install S0675202.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 227202 Z135 T-CON control board assembly.

 

S0827300.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 T-CON control board assembly P/N ??????. 

 

1.      Click on the file link HERE (Install S0827300.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the ???????? Z135 T-CON control board assembly.

 

S0676100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 P-CON control board assembly P/N 101003, serial numbers 101 and after. 

 

1.      Click on the file link HERE (Install S0676100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 101003 Z135 P-CON control board assembly. 

 

S0676110.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 P-CON control board assembly P/N 119791. 

 

1.      Click on the file link HERE (Install S0676110.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 119791 Z135 P-CON control board assembly. 

 

S0676200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 P-CON control board assembly P/N 139646. 

 

1.      Click on the file link HERE (Install S0676200.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 139646 Z135 P-CON control board assembly. 

 

S0676201.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 P-CON control board assembly P/N 227203. 

 

1.      Click on the file link HERE (Install S0676201.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 227203. Z135 P-CON control board assembly.

 

S0828301.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 P-CON control board assembly P/N ????????. 

 

1.      Click on the file link HERE (Install S0828301.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the ?????????. Z135 P-CON control board assembly.

 

S0677100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 S-CON control board assembly P/N 94978, serial number 101 through current production machines. 

 

1.      Click on the file link HERE (Install S0677100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 94978 Z135 control board assembly. 

 

S0677110.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 S-CON control board assembly P/N 119790. 

 

1.      Click on the file link HERE (Install S0677110.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 119790 Z135 control board assembly.

 

S0677200.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 S-CON control board assembly P/N 139647. 

 

1.      Click on the file link HERE (Install S0677200.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 139647 Z135 control board assembly.

 

S0829300.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 S-CON control board assembly P/N ????????. 

 

1.      Click on the file link HERE (Install S0829300.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the ??????? Z135 control board assembly.

 

S0681100.exe

Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program. 

 

This application is used on Z135 D-CON control board assembly P/N 101004, serial number 101 through current production machines. 

 

1.      Click on the file link HERE (Install S0681100.exe). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      When the setup window appears, pick YES on the license agreement.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Pick Custom and click Next.

7.      Check all items on the list to install.  You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.

8.      The files will be installed.  Click here to open WebGPI Application Interface Procedure to interface the 101004 Z135 control board assembly. 

 

 

________________________________________________________________________________________________________________________________________________________

Boot File Download

Note:  Boot file download may be performed with PC/laptop using WebGPI 1.01 or higher, or using a Palm handheld with WebGPI-PDA version 1.30, build 27 or higher. 

 

ALC1000 / S1XX only

 

L0068303.hex

Note: This installation file is to load the kernel hex file onto your PC/laptop or Palm for use with the WebGPI program. 

 

This Application is used on S100/120 (serial numbers 103/101 through 131/313) T-CON.

 

1.      Click on the file link HERE (Install L0068303.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip.  The file will be installed.  Pick OK. 

7.      Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI to load the kernel onto the 50153 S100/120 T-CON. 

 

L0068304.hex

Note: This installation file is to load the kernel hex file onto your PC/laptop for use with the WebGPI program. 

 

This Application is used on S100/120 (serial numbers 103/101 through 131/313) T-CON.

 

1.      Click on the file link HERE (Install L0068304.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK. 

6.      Click Unzip.  The file will be installed.  Pick OK. 

7.      Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI to load the kernel onto the 50153 S100/120 T-CON. 

 

L0068317.hex

Note: This installation file is to load the kernel hex file onto your PC/laptop for use with the WebGPI program. 

 

This Application is used on Z80 and Z135 (serial numbers 101 through current production) T-CON.

 

1.      Click on the file link HERE (Install L0068317.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip.  The file will be installed.  Pick OK. 

7.      Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

9.      Open WebGPI to download the Z80 or Z135 boot file. 

 

L0069000.hex

Note: This installation file is to load the boot file needed to download the kernel onto your PC/laptop for use with the WebGPI program. 

 

This Application is used on HC08 hardware on S100/125, Z80 P-CON and D-CON.

 

1.      Click on the file link HERE (Install L0069000.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip.  The file will be installed.  Pick OK. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.  The file will be installed.  Open WebGPI to interface the 81542 S80/85 serial numbers 3082 through 3423. 

 

L0087100.hex

Note: This installation file is to load the boot file needed to download the kernel onto your PC/laptop for use with the WebGPI program. 

 

This Application is used on some S100/125 (after serial numbers 101/103); Z80 (serial numbers 101 through current production) D-CON, and Z135 (serial numbers 101 through current production) D-CON and P-CON.

 

1.      Click on the file link HERE (Install L0087100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Check all items on the list to install.  If you have limited hard drive space, uncheck the documentation.  You need the Application HTML files, Application HEX files, Objects, and HC12A Kernel Files minimum. Click Next.

7.      The file will be installed. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

9.      Open WebGPI to interface the 88052 P-CON or D-CON control board and download boot file.

________________________________________________________________________________________________________________________________
Kernel File Download

Note:  A PC/laptop or a Palm OS handheld with WebGPI-PDA version 1.30, build 27 or higher, is needed to download a kernel file to a control board.  

 

L0047304.hex

1.      If you do not have the L0047304.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0047304.hex onto your PC/laptop or for use on your Palm OS handheld. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGPI Download Procedure to download to the control card (Boot File L0069000 must be installed to download this kernel file).  Click HERE (Install L0069000.hex boot file). 

 

L0048305.hex

1.      If you do not have the L0048305.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0048305.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGPI Download Procedure to download to the control card (Boot File L0069000 must be installed to download this kernel file).  Click HERE (Install L0069000.hex boot file).

 

L0048310.hex

1.      If you do not have the L0048310.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0048310.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGP+ Download Procedure to download to the control card (Boot File L0069000 must be installed to download this kernel file).  Click HERE (Install L0069000.hex boot file).

 

L0060303.hex

1.      If you do not have the L0060303.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0060303.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK. 

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGPI Download Procedure to download to the control card (Boot File L0068303 must be installed to download this kernel file).  Click HERE (Install L0068303.hex boot file).

 

L0060304.hex

1.      If you do not have the L0060304.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0060304.hex onto your PC/laptop or Palm OS handheld. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGPI Download Procedure to download to the control card (Boot File L0068317 must be installed to download this kernel file).  Click HERE (Install L0068317.hex boot file).

 

L0060317.hex

1.      If you do not have the L0060317.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0060317.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI Download Procedure to download to the control card (Boot File L0068317 must be installed to download this kernel file).  Click HERE (Install L0068317.hex boot file).

 

L0082100.hex

1.      If you do not have the L0082100.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0082100.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK. 

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download the kernel on the 81542 control board on S80/85 serial numbers 3082 through 3423. 

9.      For download to the control card, click HERE (Install L0082100.hex).

 

L0082101.hex

1.      If you do not have the L0082101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0082101.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK. 

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download the kernel to the 89353 control board. 

9.      For instructions on using a PDA to download to the control card, click HERE (PDA Aplication Download Procedure).

 

L0089400.hex

1.      If you do not have the L0089400.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0089400.hpex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to interface the 62383 control board. 

9.      For PDA interface to the control card, click HERE (Install L0082101.hex).

 

L0090400.hex

1.      If you do not have the L0090400.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0090400.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to interface the 50154 control board. 

 

L0099101.hex

1.      If you do not have the L0099101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0099101.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK. 

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGPI to interface the 88052 control board. 

9.      For PDA interface to the control card, click HERE (Install L0082101.hex).

 

L0099102.hex

1.      If you do not have the L0099102.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0099102.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to interface the 94610 and 94947 control board. 

9.      For PDA interface to the control card, click HERE (Install L0082101.hex).

 

L0091100.hex

1.      If you do not have the L0091100.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0091100.hex onto your PC/laptop.  

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to interface the 101004 control board.

 

L0113100.hex

1.      If you do not have the L0113100.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0113100.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to interface the 101002 control board. 

 

L0123101.hex

1.      If you do not have the L0123101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0123101.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to interface the 101003 control board. 

 

L0123102.hex

1.      If you do not have the L0123101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0123102.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to interface the 101003 control board.

 

L0123103.hex

1.      If you do not have the L0123101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0123102.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to interface the 101003 control board.

 

 

L0125101.hex

1.      If you do not have the L0125101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0125101.hex onto your PC/laptop. 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder).  For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to interface the 94978 control board. 

 

________________________________________________________________________________________________________________________________
PDA XML File Installation

Note:  To use WebGPI-PDA to display or adjust values from a control board with your Palm OS device, you need:

·        Palm OS handheld with Palm OS 3.5 or later,

·        PC with Windows 95/98/ME/2000/XP/NT (with service pack 3.0 or higher) operating system,

·        HotSync serial cable compatible with your handheld (must be serial only, others with a serial and USB split will not work).

·        WebGPI-PDA program Version 1.30, Build 10 or higher on your Palm. 

 

S0513100_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S80/85 with the ALC-500 control board P/N 81542, serial numbers 3080 through 3423 to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0513100PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close.

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 81542 S80/85 serial numbers 3082 through 3423. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0513200_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S80/85 with the ALC500 control board P/N 89353, serial numbers 3080 through 3423 to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0513200_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 89353 Z60 after serial numbers 4000. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure). 

 

S0513204_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S80/85 with the ALC500 control board P/N 89353, serial numbers 3080 through 3423 to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0513204_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes. 

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

9.      Open WebGPI-PDA to interface the 81542 S80/85 serial numbers 3082 through 3423. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0513222_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on: S80/85 with the ALC-500 control board P/N 89353, serial numbers after 3486, Z45/25 with the ALC-500 control board P/N 89353, serial numbers 21564 through 22050, and Z60/34 with the ALC-500 control board P/N 89353, serial numbers after 4168.

 

1.      Click on the file link HERE (Install S0513222_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 89353 S80/85 control board after serial number 3486. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0717100_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on: Z51 with the ALC-500 control board assembly P/N 110157, serial numbers after 100.

 

1.      Click on the file link HERE (Install S0717100_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 110157 Z51 control board after serial number 100. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0717102_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on: Z51 with the ALC-500 control board assembly P/N 139505, serial numbers after  503.

 

1.      Click on the file link HERE (Install S0717102_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 139505 Z51 control board after serial number 503. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0718100_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on: S80/85 with the ALC-500 control board P/N 102625, serial numbers after 4076.

 

1.      Click on the file link HERE (Install S0718100_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 102625 S80/85 control board after serial number 4075. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0718101_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on: S80/85 with the ALC-500 control board P/N 122271, serial numbers after 5860.

 

1.      Click on the file link HERE (Install S0718101_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 122271 S80/85 control board after serial number 5860. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0718102_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on: S80/85 with the ALC-500 control board P/N 122271, serial numbers after 5897.

 

1.      Click on the file link HERE (Install S0718102_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the  S80/85 control board after serial number 5897. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0718103_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on: S80/85 with the ALC-500 control board P/N 122731, serial numbers after 7140.

 

1.      Click on the file link HERE (Install S0718103_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 122731 S80/85 control board after serial number 7140. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0780100_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on: S80/85-2008 with the ALC-500 control board P/N 121457, serial numbers after 8000.

 

1.      Click on the file link HERE (Install S0780100_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 121457 S80/85 control board after serial number 8000. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0690100_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

1.      Click on the file link HERE (Install S0690100_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 102750 Z60/34 control board after serial number 4551. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0690101_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

1.      Click on the file link HERE (Install S0690101_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 102750 Z60/34 control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0690102_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

1.      Click on the file link HERE (Install S0690102_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 102750 Z60/34 control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0690103_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

1.      Click on the file link HERE (Install S0690103_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 122924 Z60/34 control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0555100_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 88055, serial numbers 101 to 1?? to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555100_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 88055 Z80 control board before serial number 238. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0555101_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 94609, select serial numbers to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555101_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 94609 Z80 control board on selected units in Europe.  This software should be upgraded to S0555102.   

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0555102_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 94946, select serial numbers to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555102_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 94946 Z80 control board.

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0555103_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 102410, select serial numbers to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555103_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 102410 Z80 control board.

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0555104_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 102410, select serial numbers to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555104_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 102410 Z80 control board.

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0555105_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 146360, select serial numbers to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555105_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 146360 Z80 control board.

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0556100_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 88052, serial numbers 101 to 237 to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0556100_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 88052 Z80 control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0556101_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 94610, select serial numbers to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0556101_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

9.      Open WebGPI-PDA to interface the 94610 Z80 control board on selected units in Europe.  This software should be upgraded to S0556102.   

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0556102_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 94947, select serial numbers to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0556102_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 94647 Z80 control board.

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0556104_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 94947, select serial numbers to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0556104_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 111628 Z80 control board.

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0556105_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z80 with the control board P/N 146358, select serial numbers to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0556105_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The file will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 146358 Z80 control board.

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0648101_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S40/45 with the ALC500 control board P/N 94771, after serial number 7000 to display the information from the board onto your Palm OS device. 

 

1.      Click on the file link HERE (Install S0648101_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The files will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 94771 S40/45 control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0648102_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S40/45 with the ALC500 control board P/N 102259, after serial number 7568 to display the information from the board onto your Palm OS device. 

 

1.      Click on the file link HERE (Install S0648102_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The files will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 102259 S40/45 control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0648105_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S40/45 with the ALC500 control board P/N 102259, after serial number 11189 to display the information from the board onto your Palm OS device. 

 

1.      Click on the file link HERE (Install S0648105_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The files will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 102259 S40/45 control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0648106_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S40/45 with the ALC500 control board P/N 122922, after serial number xxxxx to display the information from the board onto your Palm OS device. 

 

1.      Click on the file link HERE (Install S0648106_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The files will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 122922 S40/45 control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0649100_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S60/65 with the ALC500 control board P/N 94772, after serial number 9807 to display or adjust values from the board with your Palm OS device. 

 

1.      Click on the file link HERE (Install S0649100_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The files will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 94772 S60/65 control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0649101_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S60/65 with the ALC500 control board P/N 106349, after serial number 10325 to display or adjust values from the board with your Palm OS device. 

 

1.  Click on the file link HERE (Install S0649101_PDA.xml). 

2.  On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.  On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.  If a window appears about WinZip Self-Extractor licensing, pick OK.

5.  Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.  Click Unzip. 

7.  The files will be installed.  Select Close. 

8.  HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.  Open WebGPI-PDA to interface the 106349 S60/65 control board. 

10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0649102_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S60/65 with the ALC500 control board P/N 110161, after serial number 12271 to display or adjust values from the board with your Palm OS device.

 

1.  Click on the file link HERE (Install S0649102_PDA.xml). 

2.  On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.  On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.  If a window appears about WinZip Self-Extractor licensing, pick OK.

5.  Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.  Click Unzip. 

7.  The files will be installed.  Select Close. 

8.  HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.  Open WebGPI-PDA to interface the 110161 S60/65 control board. 

10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0649103_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S60/65 with the ALC500 control board P/N 110161, after serial number 14044 to display or adjust values from the board with your Palm OS device.

 

1.  Click on the file link HERE (Install S0649103_PDA.xml). 

2.  On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.  On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.  If a window appears about WinZip Self-Extractor licensing, pick OK.

5.  Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.  Click Unzip. 

7.  The files will be installed.  Select Close. 

8.  HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.  Open WebGPI-PDA to interface the 110161 S60/65 control board. 

10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0649104_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on S60/65 with the ALC500 control board P/N 139499, after serial number 19606 to display or adjust values from the board with your Palm OS device.

 

1.  Click on the file link HERE (Install S0649104_PDA.xml). 

2.  On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.  On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.  If a window appears about WinZip Self-Extractor licensing, pick OK.

5.  Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.  Click Unzip. 

7.  The files will be installed.  Select Close. 

8.  HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.  Open WebGPI-PDA to interface the 139499 S60/65 control board. 

10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0662100_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

This XML file is used on Z45/Z45 Narrow with the ALC500 control board P/N 94773, after serial number 22051 to display the information from the board onto your Palm OS device. 

 

1.      Click on the file link HERE (Install S0662100_PDA.xml). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.      Click Unzip. 

7.      The files will be installed.  Select Close. 

8.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.      Open WebGPI-PDA to interface the 94773 Z45/Z45N control board. 

10.  For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0662101_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

1.  Click on the file link HERE (Install S0662101_PDA.xml). 

2.  On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.  On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.  If a window appears about WinZip Self-Extractor licensing, pick OK.

5.  Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.  Click Unzip. 

7.  The files will be installed.  Select Close. 

8.  HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.  Open WebGPI-PDA to interface the 106348 Z45/Z45N control board. 

For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0662103_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

1.  Click on the file link HERE (Install S0662103_PDA.xml). 

2.  On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.  On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.  If a window appears about WinZip Self-Extractor licensing, pick OK.

5.  Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.  Click Unzip. 

7.  The files will be installed.  Select Close. 

8.  HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.  Open WebGPI-PDA to interface the 110164 Z45/Z45N control board. 

For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0662104_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

1.  Click on the file link HERE (Install S0662104_PDA.xml). 

2.  On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.  On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.  If a window appears about WinZip Self-Extractor licensing, pick OK.

5.  Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.  Click Unzip. 

7.  The files will be installed.  Select Close. 

8.  HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.  Open WebGPI-PDA to interface the 110164 Z45/Z45N/Z45M control board. 

For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

S0662106_PDA.xml

Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program. 

 

1.  Click on the file link HERE (Install S0662106_PDA.xml). 

2.  On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.

3.  On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.  If a window appears about WinZip Self-Extractor licensing, pick OK.

5.  Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI).  Pick OK.

6.  Click Unzip. 

7.  The files will be installed.  Select Close. 

8.  HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

9.  Open WebGPI-PDA to interface the 139502 Z45/Z45N/Z45M control board. 

For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).

 

________________________________________________________________________________________________________________________________________________________
PDA HEX File Installation

Note:  To use WebGPI-PDA to download software to a control board, you need

·        Palm OS handheld with Palm OS 3.5 or later,

·        PC with Windows 95/98/ME/2000/XP/NT (with service pack 3.0 or higher) operating system,

·        HotSync serial cable compatible with your handheld (must be serial only, others with a serial and USB split will not work).

·        WebGPI-PDA software loaded on your Palm handheld.

 

S0277101.hex

This HEX file was used on S100/120 T-CON control box P/N 50153, serial numbers 101/103 through 130/312 to download the application to the control board using your Palm OS device.

 

Note:  Control boards with this software should be upgraded to S0277108 software for units with prEN280 load sense system and S0277110 software for EN280 load sense system.  Updating from S0277101 requires both a boot file and kernel file update as well.  (Boot File L0068304 and Kernel File L0060304)

 

S0277108.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S100/120 T-CON control box P/N 50153, after serial numbers 130/312 to download the application to the control board using your Palm OS device.

 

1.      Click on the file link HERE (Install S0277108.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.  (Note: Palm with can only be used to download this software.  There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)

8.      Open WebGPI to download this application to the 50153 control box on S100/120.  This board uses a 167 Microcontroller type.

 

S0277110.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S100/120 T-CON control box P/N 50153, after serial numbers 130/312 to download the application to the control board using your Palm OS device.

 

1.      Click on the file link HERE (Install S0277110.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.  (Note: Palm can only be used to download this software.  There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)

8.      Open WebGPI to download this application to the 50153 control box on S100/120. 

 

S0277111.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S100/120 T-CON control box P/N 50153 and 102696, after serial numbers 130/312 to download the application to the control board using your Palm OS device.

 

1.      Click on the file link HERE (Install S0277111.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.  (Note: Palm can only be used to download this software.  There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)

8.      Open WebGPI to download this application to the 50153 and 102696 control box on S100/120. 

 

S0278101.hex

This HEX file was used on S100/120 P-CON control box P/N 62383, serial numbers 101/103 through 130/312 to download the application to the control board using your Palm OS device. 

 

Note:  Control boards with this software should be upgraded to S0278108 software for units with prEN280 load sense system and S0278110 software for EN280 load sense system.  Updating from S0278101 requires a kernel file update as well.  (Kernel File L0048310)

 

S0278108.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S100/120 T-CON control box P/N 62383, after serial numbers 130/312 to download the application to the control board using your Palm OS device.

 

1.      Click on the file link HERE (Install S0278108.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      Click Next.  The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.  (Note: Palm can only be used to download this software.  There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)

8.      Open WebGPI to download this application to the 62383 control board.  This board uses a HC08 Microcontroller type. 

 

S0278110.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S100/120 T-CON control box P/N 62383, after serial numbers 130/312 to download the application to the control board using your Palm OS device.

 

1.      Click on the file link HERE (Install S0278110.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.  (Note: Palm can only be used to download this software.  There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)

8.      Open WebGPI to download this application to the 62383 control board.  This board uses a HC08 Microcontroller type. 

 

S0279101.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 and S100/120 D-CON control board assembly P/N 50154, serial numbers 101 and 101/103 respectively the application to the control board using your Palm OS device.

 

1.      Click on the file link HERE (Install S0279101.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.  (Note: Palm can only be used to download this software.  There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)

8.      Open WebGPI to download this application to the 50154 control board.  This board uses a HC08 Microcontroller type. 

 

S0513100.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S80/85 with the ALC-500 control board P/N 81542, serial numbers 3080 through 3423 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0513100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 81542 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0513200.hex

 

This HEX file was used on Z60 with the ALC-500 control board P/N 89353, serial numbers 4001. 

 

Note:  All control boards with this software should be upgraded to S0513222 software. 

 

S0513204.hex

 

This HEX file is used on S80/85, Z60, and Z45 with the ALC-500 control board P/N 89353, serial numbers 3424 / 4001 / 21180 through 3486 / 4168 / 21563, respectively. 

 

Note:  Control boards with this software should be upgraded to S0513222 software. 

 

S0513222.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S80/85, Z60, and Z45 with the ALC-500 control board P/N 89353, serial numbers 3487 / 4169 / 21564 through current/ current / 22050, respectively. 

 

1.      Click on the file link HERE (Install S0513222.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 89353 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure). 

 

S0718100.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S80/85 with the ALC-500 control board P/N 102625, serial numbers after 4075. 

 

1.      Click on the file link HERE (Install S0718100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 102625 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure). 

 

S0718101.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S80/85 with the ALC-500 control board P/N 122271, serial numbers after 5861. 

 

1.      Click on the file link HERE (Install S0718101.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 122271 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure). 

 

S0718102.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S80/85 with the ALC-500 control board P/N 122271, serial numbers after 5898. 

 

1.      Click on the file link HERE (Install S0718102.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 122271 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0718103.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S80/85 with the ALC-500 control board P/N 122731, serial numbers after 7140. 

 

1.      Click on the file link HERE (Install S0718103.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 122731 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0780100.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S80/85-2008 with the ALC-500 control board P/N 122457, serial numbers after 8000. 

 

1.      Click on the file link HERE (Install S0780100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 122457 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0690100.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on  Z60 with the ALC-500 control board P/N 102750, serial numbers after 4551. 

 

1.      Click on the file link HERE (Install S0690100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 102750 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure). 

 

S0690101.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on  Z60 with the ALC-500 control board P/N 102750, serial numbers after 6107. 

 

1.      Click on the file link HERE (Install S0690101.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open.  

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 102750 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure). 

 

S0690102.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on  Z60 with the ALC-500 control board P/N 102750, serial numbers after 6388. 

 

1.      Click on the file link HERE (Install S0690102.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 102750 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure). 

 

S0690103.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z60 with the ALC-500 control board P/N 122924, serial numbers after xxxx. 

 

1.      Click on the file link HERE (Install S0690103.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 122924 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure). 

 

S0555100.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 T-CON control board P/N 88055, serial numbers 101 through 237 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.   

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 88055 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0555101.hex

This HEX file is used on Z80 T-CON control board P/N 94609, select serial numbers up to 237. 

 

Note:  Control boards with this software should be upgraded to S0555102 software.

 

S0555102.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 T-CON control board P/N 94946, after serial number 237 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555102.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGPI to download this application to the 94946 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0555103.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 T-CON control board P/N 102410, after serial number 453 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555103.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGPI to download this application to the 102410 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0555104.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 T-CON control board P/N 102410, after serial number 453 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555104.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGPI to download this application to the 102410 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0555105.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 T-CON control board P/N 146360, after serial number 2501 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0555105.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.

8.      Open WebGPI to download this application to the 146360 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0556100.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 P-CON control board P/N 88052, serial numbers 101 through 237 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0556100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 88052 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0556101.hex

 

This HEX file is used on Z80 control board P/N 94610, select serial numbers up to 237. 

 

Note:  Control boards with this software should be upgraded to S0556102 software.

 

S0556102.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 control board P/N 94947, after serial number 237 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0556102.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 94947 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure). 

 

S0556104.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 control board P/N 111628, after serial number 928 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0556104.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 111628 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0556105.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 control board P/N 146358, after serial number 2501 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0556105.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK. 

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 146358 control board. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0613102.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z80 and S100/120 D-CON control board assembly P/N 50154, serial numbers 101 and 101/103 respectively the application to the control board using your Palm OS device.

 

1.      Click on the file link HERE (Install S0613102.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.   

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 62383 control board.  This board uses a HC08A Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0648101.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S40/45 with the ALC-500 control board P/N 94771, after serial number 7000 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0648101.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 94771 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0648102.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S40/45 with the ALC-500 control board P/N 102259, after serial number 7568 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0648102.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 102259 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0648105.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S40/45 with the ALC-500 control board P/N 102259, after serial number 11189 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0648105.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 102259 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0648106.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S40/45 with the ALC-500 control board P/N 122922, after serial number xxxxx to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0648106.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 122922 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0649100.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S60/65 with the ALC-500 control board P/N 94772, after serial number 9153 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0649100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 94772 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0649101.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S60/65 with the ALC-500 control board P/N 106349, after serial number 10325 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0649101.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 106349 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0649102.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S60/65 with the ALC-500 control board P/N 110161, after serial number 12272 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0649102.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 110161 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0649103.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S60/65 with the ALC-500 control board P/N 110161, after serial number 14044 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0649103.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 110161 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0649104.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on S60/65 with the ALC-500 control board P/N 139499, after serial number 19607 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0649104.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 139499 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0662100.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z45 IC with the ALC-500 control board P/N 94773, after serial number 22050 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0662100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 94773 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0662101.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z45 IC with the ALC-500 control board P/N 106348, after serial number 23384 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0662101.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 106384 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0662103.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z45 IC with the ALC-500 control board P/N 106348, after serial number 23384 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0662103.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 106384 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0662104.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z45 IC with the ALC-500 control board P/N 110164, after serial number 30141 to download the application to the control board using your Palm OS device.

And Z45M with the ALC-500 control board P/N 110164, after serial number 100.                                      

 

1.      Click on the file link HERE (Install S0662104.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 110164 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0662106.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z45 IC with the ALC-500 control board P/N 139502, after serial number 38093 to download the application to the control board using your Palm OS device.

And Z45M with the ALC-500 control board P/N 139502 after serial number 1422. 

 

1.      Click on the file link HERE (Install S0662106.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 139502 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0717100.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z51 with the ALC-500 control board P/N 110157, after serial number 100 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0717100.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 110157 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

 

S0717102.hex

Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program. 

 

This HEX file is used on Z51 with the ALC-500 control board P/N 139505, after serial number 503 to download the application to the control board using your Palm OS device. 

 

1.      Click on the file link HERE (Install S0717102.hex). 

2.      On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.”  And press OK.  For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?”  Select Open. 

3.      On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.

4.      If a window appears about WinZip Self-Extractor licensing, pick OK.

5.      Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder).  Click Next.

6.      The file will be installed. 

7.      HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. 

8.      Open WebGPI to download this application to the 139505 control board with the HC12 Microcontroller type. 

9.      For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).

________________________________________________________________________________________________________________ 


 

WebGPI Application Interface Procedure

To interface with a control board, you need:

·        WebGPI version 1.01a or later installed on the computer,

·        Available COM port,

·        RS-232 cable (serial cable, 9-pin),

·        For S100/120 machines T-Harness part number 75094,

·        Internet Explorer 5.0 or later, and

·        The appropriate application (*.exe) installed on the computer.

 

  1. Power up the PC/laptop. 
  2. Connect RS-232 cable or T-Harness to PC/laptop. 
  3. Connect other end of RS-232 cable to the control board you want to interface.  For S100/120 connect the T-Harness to the control box and the existing harness. 
  4. Open WebGPI. 
  5. Power up the control board
  6. Select Connect on the buttons at the top of the screen.  (If WebGPI fails to connect, make sure there is power to the control board then select Connect again) 
  7. Select Application button (next to where the Connect button has now changed to read Disconnect).
  8. A list of folders/items you can look at displays on the left side of the window. 
  9. From the menu, select screen to display.  ONLY use screens for the machine and engine programmed on the board.  Machine model and engine can be found on the Models Specification screen on the ALC-500 or the Machine screen on the ALC1000 software. 
  10. If programming the board after a software download, set model and engine configuration first.  Machine model and engine can be found in the Setup folder and select Model screen on the ALC-500 or the Machine screen on the ALC1000 software. 
  11. Click on a folder and select and item in the list to view in the window. 
  12. To change an item, highlight the item in the window, type in the new value or pick from the list and select Send to save the change to the control board. 
  13. To change back to factory defaults values for the screen, select Default. 
  14. To end connection to the control board, select Disconnect button. 

 

________________________________________________________________________________________________________________________________________________________


WebGPI-PDA Application Interface Procedure

Not available for S100/120 control boards. 

Note:  To interface with a control board using WebGPI-PDA, you need a

·        Palm OS handheld with Palm OS 3.5 or later,

·        Gender changer Radio Shack part number 950-025x or equivalent,

·        Null Modem cable or adapter Female DB9 – Male DB9,

·        appropriate xml or hex file installed on Palm (see above for correct selection of files),

·        and a HotSync serial cable compatible with your handheld (must be serial only, others with a serial and USB split will not work).

·        WebGPI-PDA program Version 1.30, Build 10 or higher on your Palm. 

 

  1. Connect null model cable/adapter to the gender adapter. 
  2. Connect the gender adapter to the HotSync cable. 
  3. Connect the null modem (attached to HotSync cable) to the control card. 
  4. Connect HotSync cable to Palm handheld. 
  5. Turn on Palm and open WebGPI. 
  6. From the main menu, select Application. 
  7. From the menu, select screen to display.  ONLY use screens for the machine and engine programmed on the board.  Machine model and engine can be found on the Models Specification screen on the ALC-500 or the Machine screen on the ALC1000 software. 
  8. If programming the board after a software download, set model and engine configuration first. 
  9. Click on a folder and select and item in the list to view in the window.
  10. To change an item, tap the number/item to be changed.  Use the backspace to remove the current value and type in the new value or pick from the list and select Send to save the change to the control board. 
  11. To change back to factory defaults values for the screen, select Default. 
  12. To end connection to the control board, select Disconnect button.

________________________________________________________________________________________________________________________________________________________

 

WebGPI Kernel Download Procedure

To interface with a control board, you need

·        WebGPI version 1.01a or later installed on the computer,

·        Available COM port,

·        RS-232 cable,

·        For S100/120 machines T-Harness part number 75094,

·        And the appropriate application (*.exe) installed on the computer.

 

  1. Power up the PC/laptop. 
  2. Connect RS-232 cable or T-Harness to PC/laptop. 
  3. Connect other end of RS-232 cable to the control board you want to download to.  For S100/120 connect the T-Harness to the control box and the existing harness. 
  4. Open WebGPI. 
  5. If you are upgrading software on a machine follow steps 6 through 8, otherwise go to step 9.
  6. Select Connect on the buttons at the top of the screen. 
  7. Select Application.
  8. For ALC500, look at each valve function and record the max out value for each function (A list of folders/items you can look at displays on the left side of the window.  Example: Fwd, Rev, Boom 1 Up, Boom 1 Down…).  On Z80 and S100/120 machines, record neutral voltage values for each steer sensor, turntable level sensors, and angle values for the PBAS (Z80 only). 
  9. Select Download on the buttons at the top of the screen. 
  10. Select Microcontroller Type below the buttons.  Note: For PC/laptops using WebGPI version 1.01a, use HC08A for HC12 Microcontroller type. 
  11. For ALC1000 or S100/120, the boot file needs to be downloaded before the kernel can be downloaded. 
  12. For WebGPI 1.01 download the kernel as an application.
  13. Select the kernel file you need to download to the card by using search.  Kernel files are found at C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles\<kernel file>.hex.  NOTE: Downloading a kernel to a control card will wipe out ALL information currently on the card. 
  14. Click Download to begin downloading to the control board.  The HC12 Microcontroller requires a Force Download for the kernel download.  If downloading does not begin in a few seconds and an error message appears, select Force Download and follow the instructions on the screen.   
  15. Cycle the power to the control card to complete the download process. 
  16. To end connection to the control board, select Exit button.  To load an application, click here to go to the WebGPI Application Download Procedure. 

 

________________________________________________________________________________________________________________________________________________________

 

WebGPI Application Download Procedure

To download the application to a control board, you need:

·        WebGPI version 1.01a or later installed on the computer,

·        Available COM port,

·        RS-232 cable,

·        For S-1XX machines T-Harness part number 75094, and

·        The appropriate application (*.exe) installed on the computer.

 

  1. Power up the PC/laptop. 
  2. Connect RS-232 cable or T-Harness to PC/laptop. 
  3. Connect other end of RS-232 cable to the control board you want to download to.  For S100/120 connect the T-Harness to the control box and the existing harness. 
  4. Power the control board. 
  5. Open WebGPI. 
  6. Select Connect on the buttons at the top of the screen.  (Note: Button text changes to Disconnect and penguin to the right of the buttons changes to a flying bird when WebGPI is connected to the control card.)
  7. Select Application.
  8. If you are updating the software on the control card, for ALC-500, look at each valve function and record the max out value for each function (Example: Fwd, Rev, Boom 1 Up, Boom 1 Down…).  For Z80 and S100/120 machines, record neutral voltage values for each steer sensor, turntable level sensors (both X and Y), and angle values for the PBAS (Z80 only).  If you are downloading an application after a kernel download, only the program default values will be present and need not be recorded. 
  9. Select Disconnect.
  10. Select Download.  (If error message for no Microcontroller selected appears, select Ok)
  11. Select Microcontroller Type below the buttons.  Note: For PC/Laptops using WebGPI v1.01a, use HC08A for HC12 Microcontroller Type.
  12. Select Search next to the Application-File menu and open C:\Program Files\Sauer-Danfoss\WebGPI\<Application Folder>\<Application File>.hex. 
  13. Select Download. 
  14. When download is complete, cycle power to the control board. 
  15. Select Exit.
  16. Select Connect.
  17. Select Application.
  18. Select Set All Defaults for final step of application installation. 
  19. If values were recorded prior to application download, enter those values into the appropriate screens (See WebGPI Interface Procedure step 10 for changing values.). 
  20. To end connection to the control board, select Disconnect button. 

 

________________________________________________________________________________________________________________________________________________________

 

WebGPI Application Download Procedure for ALC500 Gen II PCB

To download the application to a control board, you need:

·        WebGPI version 3.0 or later installed on the computer,

·        Available COM port,

·        RS-232 cable,

·        The appropriate application (*.exe) installed on the computer.

 

  1. Power up the PC/laptop. 
  2. Connect RS-232 cable or T-Harness to PC/laptop. 
  3. Connect other end of RS-232 cable to the control board you want to download to. 
  4. Power the control board. 
  5. Open WebGPI. 
  6. Select Connect on the buttons at the top of the screen.  (Note: Button text changes to Disconnect and penguin to the right of the buttons changes to a flying bird when WebGPI is connected to the control card.)
  7. Select Application on the buttons at the top of the screen.

a)      If you are updating the software on the control card, look at each valve function and record the threshold and max out value for each function (Example: Fwd, Rev, Boom 1 Up, Boom 1 Down, etc…). 

  1. Select Disconnect on the buttons at the top of the screen.
  2. Select Download.  (Error message for no Microcontroller selected appears, select Ok, go to step 11) 
  3. Select Connect.  (Microcontroller type will be automatically selected)
  4. Select Kernel for File type.
  5. Select Search next to the Operating System File menu and open C:\Program Files\Sauer-Danfoss\WebGPI\<Application Folder>\<Application File>.hex. 
  6. Select Download in the File Type section, next to Exit button. 
  7. When download is complete, Kernel window will display 100%, cycle power to the control board. 
  8. Select Exit.
  9. Select Connect.
  10. Select Application.
  11. Select Set All Defaults for final step of application installation. 
  12. If values were recorded prior to application download, enter those values into the appropriate screens (See WebGPI Interface Procedure step 10 for changing values.). 
  13. To end connection to the control board, select Disconnect button. 

 

________________________________________________________________________________________________________________________________________________________

 

WebGPI-PDA Application Download Procedure

Not available for S100/120 control boards and ALC500 Gen II control board

Note:  To interface with a control board using WebGPI-PDA, you need a

·        Palm OS handheld with Palm OS 3.5 or later,

·        Gender changer Radio Shack part number 950-025x or equivalent,

·        Null Modem cable or adapter Female DB9 – Male DB9,

·        WebGPI-PDA program Version 1.30, Build 10 or higher on your Palm. 

·        Appropriate xml and hex file installed on Palm (see table above for correct selection of files), and

·        A HotSync serial cable compatible with your handheld (must be serial only, others with a serial and USB split will not work).

 

  1. Connect null model cable/adapter to the gender adapter. 
  2. Connect the gender adapter to the HotSync cable. 
  3. Connect the null modem (attached to HotSync cable) to the control card. 
  4. Connect HotSync cable to Palm handheld. 
  5. Turn on Palm and open WebGPI. 
  6. If you are updating the software on the control card, for ALC-500, look at each valve function and record the max out value for each function (Example: Fwd, Rev, Boom 1 Up, Boom 1 Down…).  For Z80 and S100/120 machines, record neutral voltage values for each steer sensor, turntable level sensors (both X and Y), and angle values for the PBAS (Z80 only).  If you are downloading an application after a kernel download, only the program default values will be present and need not be recorded. 
  7. From the main menu, select App Download. 
  8. Select Connect.  If the PDA will not connect to the control board, go back to step 7, select App Download, select Force Download; then goto Step 10. 
  9. Select Download.                        
  10. Select Start on the screen giving instructions for a Force Download on the HC12 Microcontroller Type.  (Not all versions of WebGPI-PDA will have this screen appear.) 
  11. Select Microcontroller Type (see table above).  NOTE: Some later versions of WebGPI-PDA will automatically detect the Microcontroller Type when the PDA connects to the card. 
  12. Select OK. 
  13. WebGPI-PDA 1.30 build 27 or higher: If the Microcontroller selected is HC12, the PDA may automatically start a Force Download process.  Follow instructions on the screen.
  14. Select the check box to Show All File Types, then select the application file to download to the control board. 
  15. Select Start.  The PDA will begin to download the application. 
  16. Wait until the screen displays file downloaded with a Close button.  Do NOT hit cancel. 
  17. At the File Downloaded screen, select Close.
  18. Select Close. 
  19. Cycle the power to the control card. 
  20. From the main menu, select Application. 
  21. On ALC500 control cards, from the screen menu, select Parameter Defaults. 
  22. Select send to set all parameters to the factory defaults for the new application you just downloaded.  (If no Parameter Defaults screen is available, go through each screen on the menu and select Default button.) 
  23. Select Back. 
  24. Go to WebGPI-PDA Interface Procedure to setup control card. 

 

________________________________________________________________________________________________________________________________________________________

 

Connecting to S60HC Plus+1 Modules in the field (after S/N 14191)

Note:  To interface with a control board using PLUS+1 Service Tool Software, you need a

 

  • Laptop
  • HARNESS PROGRAM CAN PLUS1 (P/N 110803)
  • CABLE,PROGRAMMING,PLUS1 (P/N 119604)
  • PLUS+1 Service and Diagnostic Tool PC Software

 

Obtaining Plus+1 Service and Diagnostic Tool:

(NOTE: Internet access required)

1.      Fill out the PLUS+1 GUIDE Download Request Form on the Sauer-Danfoss website. Click here (Request File) or copy and paste the link below into a browser                                                              http://www.sauer-danfoss.com/Products/MobileElectronics/PLUS1Guide/PLUS1GuideDownloads/PLUS1GUIDEServiceToolSoftwareLicense/RequestForm/index.htm

2.      After hitting Send check your email for a message from PLUS+1 License Auto Activation. The subject line will be “Plus+1 GUIDE Web Site Registration”. Click on the PLUS+1 download link in the message.

3.      The link opens a browser page titled PLUS+1 Software Download & License. Select the GUIDE Service Tool (free service tool only) download and install it on your computer. The download & license are free and the license does not expire.

4.      You should now be able to use the Service Tool part of PLUS+1 GUIDE.


 

Connecting to Plus+1 on S60HC:

1.      Connect CABLE,PROGRAMMING,PLUS1 (P/N 119604) to USB port on laptop.

2.      Connect HARNESS PROGRAM CAN PLUS1 (P/N 110803) to cable.

3.      Connect harness to S60HC next to ground box.) Unplug the terminating resistor. Insert receptacle on the programming harness unto the plug from which the terminating resistor was removed.  Plug the terminating resistor that was removed unto the plug on the programming harness.

 

Normal

w/ Harness

 

 

 

 

 

 

 

 

 

 

 

 


4.      Turn key switch to ground and cycle power.

5.      Start Plus+1 Service tool on the PC by clicking on its icon.

a.       Plus+1 Service Tool program will scan connected controller automatically.  Note: To scan connected Plus 1 controllers again press F8 or select Scan System from File menu.

6.      Green block with word Connect will be displayed at the bottom of the Plus+1 Service Tool program window, indicating successful connection between PC and Plus 1 controller.

 

 

 

 

 

7.      Click on the file open icon and browse to the directory where the diagnostic file is stored.  The diagnostic file has a *.P1D file name extension.  The S60HC diagnostic file is named “TCON-SCON SERVICE TOOL_REVA.P1D.”

a.       If “Replace ECU” warning message appears, click Cancel.

 

 

Updating Plus+1 software on S60HC:

1.      Perform instructions in section C.

2.      Click File Download icon, or select File Download from File menu.

3.      Menu will roll down on the left side of the tool in Diagnostic Navigator tab.

4.      Click on Controller Application (in bold) on the menu in the Diagnostic Navigator tab. Select appropriate application to download from Open file for download dialog window and click Open button.

a.       Verify the SCON software is going to the correct node.

 

File Download

SCON: 1st node

 

 

 

 

 

 

 

 

 

 

 

 

 


5.      Plus+1 Service Tool program will read application file and display its information. Make sure correct application file was selected.

a.       Note: The following warning message could pop-up: click Ignore button.

 

 

 

 

 

 

6.      Click Start Download button to begin downloading.

a.       Note: The follow message pop-up:

 

 

 

 

 

 

b.      Confirm new application type. Type in the window: SCON or TCON, depend on which application will be downloaded and press OK. (case sensitive)

 

7.      Running bar in Plus+1 Service Tool will be indicating downloading progress. LED on Plus+1 controller could blink randomly.

8.      After downloading is complete (for both SCON and TCON), Plus+1 Service Tool will scan connected controller automatically and display downloaded application information in Diagnostic Navigator tab, under sub tree Controller Application (click + to expand information sub tree). Make sure: App Id, App Type and App Ver. are the same as current application.

a.       Note: To scan connected Plus 1 controllers again press F8 or select Scan System from File menu.

 

SCON

TCON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.      Close Plus+1 Service Tool program, switch OFF power to Plus 1 controller and unplug the programming harness and replace the terminating resistor receptacle to it’s mating plug on the S60HC

10.  Plus+1 controller is programmed.

11.  Set defaults.

12.  Perform a full system calibration per Service Manual.

 

Connecting to Plus+1 on Z40:

8.      Connect CABLE,PROGRAMMING,PLUS1 (P/N 119604) to USB port on laptop.

9.      Connect HARNESS PROGRAM CAN PLUS1 (P/N 110803) to cable.

10.  Connect harness to Z40 next to ground box.) Unplug the terminating resistor. Insert receptacle on the programming harness unto the plug from which the terminating resistor was removed.  Plug the terminating resistor that was removed unto the plug on the programming harness.

11.  Turn key switch to ground and cycle power.

12.  Start Plus+1 Service tool on the PC by clicking on its icon.

a.       Plus+1 Service Tool program will scan connected controller automatically.  Note: To scan connected Plus 1 controllers again press F8 or select Scan System from File menu.

13.  Green block with word Connect will be displayed at the bottom of the Plus+1 Service Tool program window, indicating successful connection between PC and Plus 1 controller.

 

 

14.  Click on the file open icon and browse to the directory where the diagnostic file is stored.  The diagnostic file has a *.P1D file name extension. 

a.       If “Replace ECU” warning message appears, click Cancel.

 

Updating Plus+1 software on Z40:

13.  Perform instructions in section Connecting to Plus+1 on Z40.

14.  Click File Download icon, or select File Download from File menu.

 

File Download

 

15.  The select target ECU box will pop up. Select 0,1 - Z40TurntableControl for the first download. Click OK.

 

Target Controller

 

16.  Click on Controller Application (TCON 110985) in the Open application for download dialog window and click Open button.

 

Z40 TCON

Z40 PCON

 

17.  Plus+1 Service Tool program will read application file for download and display its information. Make sure correct application file was selected.

a.       Note: The following warning message could pop-up: click Ignore button.

 

 

18.  Click Start Download button to begin downloading.

 

 

a.       Note: The following message may pop-up:

 

 

b.      Confirm new application type. Type in the window: Z40TCON or PCON, depending on which application will be downloaded and press OK. (case sensitive)

c.       Note: The following warning message could pop-up: click Ignore button.

 

 

19.  Running bar in PLUS+1 Service Tool will be indicating downloading progress. LED on PLUS+1 controller could blink randomly.

20.  After downloading is complete (for both TCON and PCON), Plus+1 Service Tool will scan connected controller automatically and display downloaded application information in Diagnostic Navigator tab, under sub tree ECU List: Z40Turntable/PlatformControl: Application (click + to expand information sub tree). Make sure: App Id, App Type and App Ver. are the same as current application.

a.       Note: To scan connected Plus 1 controllers again press F8 or select Scan System from File menu.

 

TCON

PCON

 

21.  Close Plus+1 Service Tool program, switch OFF power to Plus 1 controller and unplug the programming harness and replace the terminating resistor receptacle to it’s mating plug on the Z40

22.  Plus+1 controller is programmed.

23.  Set defaults.

24.  Perform a full system calibration per Service Manual.

 

Z40 Rev A to Rev C Upgrade Info

  1. Install AC motor controllers with Rev B Software.
    The label it will say version 17 (Rev B) or the motor controller may marked as Rev B with a black permanent marker. Rev A motor controllers are version 16.
  2. Modify Right AC motor controller harness.  Move the platform level up coil wire, V14PLUA OR, from pin 8 to pin 11. Verify that the flashing beacon, C117FB RD, is connected to pin 8. (Some beacons were hardwired to the key switch.  They can be left hard wired, but the beacon cannot be turned OFF from the VCON menu.)
  3. Follow Steps in Rev B to Rev C procedure, except do not capture and restore existing parameters.  A complete machine setup is required for upgrading from Rev A to Rev C.

 

Z40 Rev B to Rev C Software Upgrade Info and Procedure

Notes:

Installing Rev. C TCON & PCON software does not require an update to the Zapi AC motor controller software. It remains Rev. B.

**FOR UNITS WITH REV A SOFTWARE ONLY**  (There is a very limited number of Rev. A units in the field.)
To upgrade from TCON/PCON Rev. A, the AC motor controller software must also be upgraded to Rev. B.  The best procedure is to swap out the AC motor controllers with units that already have Rev. B software.

 

Procedure:

 

  1. Connect to the Z40 with the PC Service tool software - - see Connecting to Plus+1 and Updating Plus+1 Software on the boom software CD, or the Z40 Training PowerPoint. Version 3.0.5.1 or later of the Sauer Plus1 Guide Service Tool Software is required to run the Rev A service tool file.

  2. Open the Z40 service tool file. (file=>128571A.P1D)
  3. Upload Calibration Parameters from the TCON & PCON controllers and save each to a separate file.  Use the “ALL EE TCON” and “ALL EE PCON” service tool screens in the Guide service tool.  A file with an xml extension (*.xml) is created to contain the parameters uploaded from each controller.

    a. click on THE “ALL TCON EE” parameter screen
    b. click the “upload from CPU button”
    c. click the save parameters to a file button.
    d. repeat for the PCON parameters

    (The parameters are saved so calibrations can be reloaded after loading new software and setting defaults, which will save time in getting the machine back in operation. This step can be skipped if a full machine setup is planned after the software upgrade.)
  4. Download Rev C TCON Software (file=> 110985C.lhx)
    Note: If downloading to a unprogrammed controller, or if the controller is contains a different program- - the application type must be entered in the window that pops up.  The Z40 TCON controller application type is “Z40TCON”

    Also, if a message appears that say that “..memory structure is not compatible..” click the “Ignore” button.  The parameters will be restored in steps 6 and 7.
  5. Download Rev C PCON Software (file=> 110986C.lhx).  The Z40 PCON controller application type is “PCON”
  6. Set General and Calibration Defaults from the ground controls (now possible in Rev C.)  After the startup beep, press and hold both the AUX and Function Enable toggle switches ON for 5 seconds, within 10 seconds after the “system ready” beep. The parameter reset is confirmed by a long alarm “beep.”

    NOTE: this step IS NECESSARY to set values to the new parameters added to Rev C software.
  7. Load Calibration Parameters back into the machine from *.xml files that were saved in step 3.
    (Make sure all of the “download” select boxes are checked on the left side of the screen.  If not, right click on the word “download” at the top and select “Check ‘Download’ for all records”) 
    –OR-
    Perform a complete machine set up (GPM calibrate, Pressure Relief Valve Calibrate, Thresholds, Valve Threshold and Maximum Current, etc.)

    It is important to verify the values of the new parameters added in Rev C are correct. Enter the ALL EE TCON screen and verify that EE_PLATCUT=0 (unless platform level cutout is desired.)  Enter the ALL EE PCON screen and verify that EE_DITHER_AMPL=300 and EE_DITHER_FREQ=100.
  8. Verify Main Pressure Relief Calibration by operating functions against end stops.  Secondary Down => 1100 psi | Jib Up => 2100 psi | Primary Retract => 2450 psi.
    If not correct, perform a relief valve calibration. {service manual pgs. 90-91}
  9. Calibrate both joysticks {service manual page 55}
  10. Verify proper operation and function times. (times are listed since the released service manual is not completely up to date) Adjust any functions that are not operating smoothly and at the proper speed.

FUNCTION                                       TARGET TIME

Secondary Boom Up                          32 - 36 sec

Secondary Boom Down                     32 - 36 sec

Primary Boom Up                               26 - 30 sec

Primary Boom Down                          26 - 30 sec

Primary Boom Extend                                    18 - 22 sec

Primary Boom Retract                                    18 - 22 sec

Jib Boom Up                                       16 - 20 sec

Jib Boom Down                                  16 - 20 sec

Platform Rotate(CW/CCW)               10 - 14 sec

Turntable Rotate(CW/CCW)                          62 - 68 sec

Jib Rotate (CW/CCW)                        16 - 20 sec

 

Z40 Rev C to Rev D Software Upgrade Info and Procedure

Notes:

Installing Rev. D TCON & PCON software does not require an update to the Zapi AC motor controller software. It remains Rev. B.

Rev. D TCON & PCON software can be downloaded using service tool file 128571A.P1D with Version 3.0.5.1 or later of the Sauer Plus1 Guide Service Tool Software, but Version 5.0.8.7 or later of the Sauer Plus+1 Guide Service Tool Software is required to run the Rev. D diagnostic service tool file 230797A.P1D.

 

Procedure:

 

  1. Connect to the Z40 with the PC Service tool software - - see Connecting to Plus+1 and Updating Plus+1 Software on the boom software CD, or the Z40 Training PowerPoint. Version 5.0.8.7 or later of the Sauer Plus1 Guide Service Tool Software is required to run the service tool file (see note above).

  2. Open the Z40 service tool file. (file=>230797A.P1D)
  3. Download Rev D TCON Software (file=> 110985D.lhx)
    Note: If downloading to an unprogrammed controller or if the controller contains a different program- - the application type must be entered in the window that pops up.  The Z40 TCON controller application type is “Z40TCON”

    Also, if a message appears that says “...memory structure is not compatible...” click the “Ignore” button.  The parameters will be restored in steps 6 and 7.
  4. Download Rev D PCON Software (file=> 110986D.lhx). )
    Note: If downloading to an unprogrammed controller or if the controller contains a different program- - the application type must be entered in the window that pops up.  The Z40 PCON controller application type is “PCON”
  5. Set General and Calibration Defaults from the ground controls. After the startup beep, press and hold both the AUX and Function Enable toggle switches ON for 5 seconds, within 10 seconds after the “system ready” beep. The parameter reset is confirmed by a long alarm “beep.”

    NOTE: this step IS NECESSARY to set values to the new parameters added to Rev D software.
  6. Perform a complete machine set up (Pressure Relief Valve Calibrate, GPM calibrate, Valve Threshold and Maximum Current, etc.)
  7. Verify Main Pressure Relief Calibration by operating functions against end stops.  Secondary Down => 1100 psi | Jib Up => 2100 psi | Primary Retract => 2450 psi.
    If not correct, perform a relief valve calibration.
  8. Verify proper operation and function times. (times are listed since the released service manual is not completely up to date) Adjust any functions that are not operating smoothly and at the proper speed.

FUNCTION                                       TARGET TIME

Secondary Boom Up                          32 - 36 sec

Secondary Boom Down                     32 - 36 sec

Primary Boom Up                               26 - 30 sec

Primary Boom Down                          26 - 30 sec

Primary Boom Extend                        18 - 22 sec

Primary Boom Retract                        18 - 22 sec

Jib Boom Up                                       16 - 20 sec

Jib Boom Down                                  16 - 20 sec

Platform Rotate(CW/CCW)               10 - 14 sec

Turntable Rotate(CW/CCW)              62 - 68 sec

Jib Rotate (CW/CCW)                        16 - 20 sec

 

Program ALC500 using the Jumper wires:

                         

The Drive Priority using the jumper wires is not available on Revision 2.04 and early

Note: When using jumpers, One jumper on J5 and drive mode on J6 must be selected at a minimum.  Pin 6 to pin 11 may be selected in addition to drive mode to activate options.  Using Jumpers J5 and J6 will reset all parameters to defaults including Joysticks and and sensors.

 

For example: to set S80/85 4WD, Deutz 2011L04i engine, Drive Priority:

 

Perform this procedure with the boom in the stowed position.

1.      Pull out the red Emergency Stop button to the on position at ground control.

2.      Turn the key switch to Platform control.  Do not start the engine

3.      Push in the Platform control red Emergency Stop button to the off position.

4.      Do not press down the foot switch.

5.      Locate J5-Engine connector on the ALC500.  Place wire jumper between COM and Pin 11.

6.      Locate J6-Model connector on the ALC500.  Place wire jumper from COM to Pin 1 and Pin 11.

7.      Move and hold the Drive Enable toggle switch in the Right (or Left) position and pull out the red Emergency Stop button to the on position.

8.      When the alarm sounds, release the drive enable toggle switch.

 

Note:   - if alarm sounds for about 2 seconds and stops, settings are stored go to step 9.

-          If alarm sounds for 1 second ON and 1 second OFF continually, jumpers are not making contact to connector’s pins, check the jumpers and repeat procedure from 3 to end.

-          If alarm continues to sound, push E-stop to off position, one of the jumpers is not correct, check jumper connections and repeat procedure from 3 to end.

 

9.      Push in the Platform control red Emergency Stop button to the off position.

10.  Remove all jumpers.

 

11.  Calibrate machine.

 

 

 

TABLE A, J5 ENGINES FOR EACH MACHINES MODEL.

 

Pin #

J5- ENGINES

S40/45

S60/65

S80/85

S80/85 VP

Z45

Z51

Z60

Com.

COM

COM

COM

COM

COM

COM

COM

COM

1

Duetz 2011L04

 

 

X

 

 

 

 

2

Ford EFI 2.5L

X

X

X

 

X

X

X

3

Perkins 404C/704

X

X

X

 

X

 

X

4

Ford EFI 2.3L

X

X

 

 

X

X

X

5

Continental TME27

 

 

X

X

 

 

 

6

Duetz 2011L03

X

X

 

 

X

X

X

7

Deutz F4L913

 

 

X

 

 

 

 

8

GM 3.0L

 

X

X

 

 

 

 

9

Perkins 804

 

 

X

X

 

 

 

10

Perkins 404D

X

X

 

 

X

X

X

11

Deutz 2011L04i

 

 

X

X

 

 

 

 

TABLE B, J6 Model and Option for each Type of Machines.

 

Pin #

J5- options

All ALC500 Machines

Com.

COM

COM

1

4WD  (Z45)

X

2

2WD (Z45N)

X

3

Spare

 

4

Spare

 

5

 Spare

 

6

Rocker Boom2 option

(S60 High Capacity)

7

Dual Capacity option

(S60/S80)

8

Low Current Pump

X

9

 High Current Pump

X

10

Rocker Steer

X

11

 Drive Priority

 X