This CD is designed to give technicians the files needed to
adjust, update, and download the software loaded onto the control cards on
Genie self-propelled booms reaching
Model – Machine model and control module (if applicable)
SER. # – Serial number of the machine
Inc. Date – Incorporation date for the software or hardware change/release.
Hardware Assembly Part # – Genie part number for the control board with the software loaded with the defined Software Revision.
Software Revision – Revision level of the software.
Microcontroller
PC Install Program – Self-extracting files that install the needed files onto your PC/laptop for use with the WebGPI program for that software application. The WebGPI program can be ordered from Genie service parts department.
Boot File – This HEX file is needed on some control boards to load the kernel.
Kernel File – This HEX file setups up the Microcontroller to accept the application program.
PDA xml File – The xml file is used with a Palm handheld and WebGPI-PDA program to display and adjust the application information on the control board using the PDA screen. The WebGPI-PDA program can be ordered from Genie service parts department.
WebGPI/WebGPI-PDA Application File – This HEX file
holds all the values for the valve thresholds, valve max output, propel, and
all functions controlled by the control board.
This file is what that the board
uses to control the boom functions.
Cat5 Cable - An electrical cable used to connect one
electronic device to another for signal routing.
Web Browser - A software application for retrieving,
presenting, and traversing information resources. Common types include Microsoft Internet
Explorer, Google Chrome and Mozilla Firefox.
This is the software used to view the service tool application on
smartLinkTM machines.
SmartLinkTM- This is the name of the new control systems
developed totally in house by the Terex AWP Controls Engineering Team. Machine hardware will display the smartLinkTM
logo helping to identify the type of control system on the machine.
SmartLinkTM
Software:
WebGPI software 1.01a or later– Genie part number 62458 (Need Internet Explorer 5 or later)
WebGPI PDA – Version 1.30, Build 27 Genie part number 83045
WebGPI-PDA
Interface Procedure
WebGPI Kernel Download Procedure
WebGPI Application Download Procedure
WebGPI Application
Download Procedure for ALC500 Gen II PCB
WebGPI-PDA Application Download Procedure
Obtaining Plus+1 Service and Diagnostic Tool
Updating Plus+1 Software on S60HC
Updating Plus+1 Software on Z40
Z40 Rev A to Rev C Upgrade Info
Z40 Rev B to Rev C software Upgrade Info and Procedure
Z40 Rev C to Rev D software Upgrade Info and Procedure
Program ALC500 using the Jumper Wires
SER. # |
Inc. Date |
Hardware Assembly Part # |
Software Revision |
Kernel File (.hex) |
WebGPI / WebGPI-PDA Application File (.hex) |
Backward compatible |
Applicable Engines |
Comments |
|||||||||||||||||
S80/85 |
3082 |
4.8.02 |
81542 |
Rev. 1.00 |
HC12 |
N/A |
DF4L913 FORD EFI
GM 3.0L P704-33 |
Low current drive output used only
on S80/85 S/N’s 3082-3423. Do not
attempt to download Revisions other than 1.00 onto this board. Units that have had the boards replaced
after 10/15/02 will have revision 2.04 or 2.22 software. |
|||||||||||||||||
10.15.02 |
89353 |
Rev. 2.04 |
HC12 |
N/A |
|
Rev. 2.04 improves the reset to
Z45N anomaly. |
|||||||||||||||||||
3487 |
2.4.03 |
89353 |
Rev. 2.22 |
HC12 |
N/A |
*Rev.
2.22 corrects reset to Z45N and is backward compatible for all 89353
applications. |
|||||||||||||||||||
4076 |
1.6.05 |
102625 |
Rev. 1.00 |
HC12 |
|
N/A |
DEUTZ 4CYL FORD EFI
P804C GM 3.0L |
Separated from S0513222 and add brake release
on steer. Tier II parameters filled in
manually until release. |
|||||||||||||||||
5861 |
5.21.07 |
122271 |
Rev. 1.01 |
HC12 |
N/A |
DEUTZ 4CYL
FORD EFI P804C GM 3.0L
Continental TME27 |
Added Continental TME27 engine option, added
turntable rotate |
||||||||||||||||||
5898 |
6.11.07 |
122271 |
Rev. 1.02 |
HC12 |
N/A |
DEUTZ 4CYL TME27 P804C |
Bug fix - removed
conditional speed limit for turntable rotate when boom angle was greater than
15 degrees |
||||||||||||||||||
7140 |
6.16.08 |
122730 |
Rev. 1.03 |
HC12 |
N/A |
DEUTZ 2011L04i TME27 Perkins P804 |
- Add Tier 3 engines –Standardized
on Jumper Configuration pins (J5,J6) for
engines and models, -Add low/high
current propel pump option –Fixed footswitch issue when set to lockout –Fixed
footswitch water ingress causing “Valve to low” fault. |
||||||||||||||||||
3082-7999 |
11.4.10 |
T110570 |
Rev. 1.00 |
164/TI |
ONLY FOR VIEWING UPGRADE TO S0821201 |
N/A |
N/A |
N/A |
N/A |
-
Initial
Release software for
ALC500 GenII PCB only -
Add footswitch priority |
|||||||||||||||
9.25.11 |
235403 |
Rev. 2.01 |
164/TI |
NA |
NA |
NA |
NA |
|
- Fixed issue with footswitch not forcing timeout when held on startup. - Convert from prototype WebGPI library to 3.10 released
library. - Kernel application layer changed to correct random
changes to 60% current output. ECN# 11605B |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
S80/85 – 2008 |
8000-8496 |
9.22.08 |
121458 |
Rev. 1.00 |
HC12 |
N/A |
NA |
N/A |
DEUTZ 2011L04i TME27 Perkins P804 |
-
Initial
Release software for
ALC500 GenII PCB only -
Add Dual Capacity option Add footswitch priority |
|||||||||||||||
8496 |
8.31.10 |
139745 |
Rev. 1.00 |
164/TI |
ONLY FOR VIEWING UPGRADE TO S0819202 |
NA |
NA |
NA |
|||||||||||||||||
8611 |
11.8.10 |
T115457 |
Rev. 1.01 |
164/TI |
ONLY FOR VIEWING UPGRADE TO S0819202 |
NA |
NA |
NA |
N/A |
Corrected low
voltage issue with Steer and added voltage check for valve power vs. ECU
power |
|||||||||||||||
8970 |
9.25.11 |
235322 |
Rev. 2.02 |
164/TI |
N/A |
N/A |
N/A |
N/A |
-Fixed issue with footswitch not forcing timeout when held on startup. -Convert from prototype WebGPI library to 3.10 released
library. |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Z45/25 IC |
21180 |
10.10.02 |
89353 |
Rev. 2.04 |
HC12 |
N/A |
DF31011F FORD EFI P404C |
Rev. 2.04 improves the reset to
Z45N anomaly. |
|||||||||||||||||
2.4.03 |
89353 |
Rev. 2.22 |
HC12 |
N/A |
*Rev. 2.22 corrects reset to Z45N. 89353 was replaced by 236812 |
||||||||||||||||||||
22051 |
6.10.03 |
94773 |
Rev. 1.00 |
HC12 |
N/A |
DEUTZ 3CYL
FORD EFI P404C |
High
current drive output and proportional directional valves, not separate
proportional and directional valves. |
||||||||||||||||||
23385 |
5.3.04 |
106348 |
Rev. 1.01 |
HC12 |
N/A |
Tier II engines, add rocker steer
as a pin select option. Rev. 1.02
never release to production. |
|||||||||||||||||||
27000 |
9.21.05 |
110164 |
Rev. 1.03 |
HC12 |
N/A |
-Recall all default values when valid model selection jumpers are detected -Corrected the Motor Speed logic to keep the output ON during the kSpeedShftLow state -Added an OFF delay feature for the Propel brake -Modified several default values due to Function Manifold changed– Modified joystick Cal values –Change Motor shift function. |
|||||||||||||||||||
30142 |
8.15.06 |
110164 |
Rev. 1.04 |
HC12 |
N/A |
DEUTZ
3CYL FORD EFI P404C
FORD FI2.3L |
Add new 2.3L Ford engine parameters |
||||||||||||||||||
38093 |
6.23.08 |
110164 |
Rev. 1.04 |
HC12 |
N/A |
Manually change Pulse/Rev of P404C
engine from 8.9 to 10.6 Rev 1.05 never release to
production |
|||||||||||||||||||
38511 |
7.30.08 |
139502 |
Rev. 1.06 |
HC12 |
N/A |
Ford EFI 2.5L Perkins Ford EFI 2.3L Deutz 2011L03 Perkins 404D |
-
Add Tier 3 engines –Standardized on Jumper
Configuration pins (J5,J6) for engines and models, -Add low/high current propel pump option
–Fixed footswitch issue when set to lockout –Fixed footswitch water ingress
causing “Valve to low” fault. |
||||||||||||||||||
40522 |
01/11/11 |
T110562 |
Rev. 1.00 |
164/TI |
N/A |
N/A |
N/A |
N/A |
-
Initial
Release software for
ALC500 GenII PCB only Add footswitch priority |
||||||||||||||||
42621 |
9.29.11 |
235473 |
Rev. 2.00 |
164/TI |
N/A |
N/A |
N/A |
N/A |
- Nuisance Fault GenII - Monitor added to detect floating
ground. |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Z51M |
101 |
10.3.2005 |
110157 |
Rev. 1.00 |
HC12 |
N/A |
DEUTZ 3CYL |
Release software |
|||||||||||||||||
503 |
8.1.08 |
139505 |
Rev. 102 |
HC12 |
N/A |
Ford EFI 2.3L Deutz 2011L03 Perkins 404D |
Add Tier 3 engines –Standardized on Jumper Configuration pins (J5,J6) for
engines and models, -Add low/high
current propel pump option –Fixed footswitch issue when set to lockout –Fixed
footswitch water ingress causing “Valve to low” fault. Rev 1.01 never release to production. |
||||||||||||||||||
664 |
3.5.11 |
T110563 |
Rev. 1.00 |
164/TI |
N/A |
N/A |
N/A |
N/A |
-
Initial
Release software for
ALC500 GenII PCB only -
Add footswitch priority |
||||||||||||||||
??? |
??? |
235414 |
Rev. 2.00 |
164/TI |
N/A |
N/A |
N/A |
N/A |
- Nuisance Fault GenII - Monitor added to detect floating
ground. |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Z45M |
101 |
3.29.07 |
110164 |
Rev. 1.04 |
HC12 |
N/A |
DEUTZ 3CYL FORD EFI P404C
FORD FI2.3L |
Add new 2.3L Ford engine parameters |
|||||||||||||||||
1423 |
7.31.08 |
139502 |
Rev. 1.06 |
HC12 |
N/A |
Ford EFI 2.5L Perkins Ford EFI 2.3L Deutz 2011L03 Perkins 404D |
- Add Tier 3 engines –Standardized
on Jumper Configuration pins (J5,J6) for
engines and models, -Add low/high
current propel pump option –Fixed footswitch issue when set to lockout –Fixed
footswitch water ingress causing “Valve to low” fault. Rev 1.05 never release to
production. |
||||||||||||||||||
1738 |
3.5.11 |
T110562 |
Rev. 1.00 |
164/TI |
N/A |
N/A |
N/A |
N/A |
-
Initial
Release software for
ALC500 GenII PCB only Add footswitch priority |
||||||||||||||||
??? |
??? |
235473 |
Rev. 2.00 |
164/TI |
N/A |
N/A |
N/A |
N/A |
- Nuisance Fault GenII - Monitor added to detect floating
ground. |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Z60/34 |
8.12.02 |
89353 |
Rev. 2.00 |
HC12 |
N/A |
DF31011F FORD EFI P404C |
Rev. 2.00 and above is capable of
high current drive output. Should be
upgraded to Rev. 2.22 |
||||||||||||||||||
|
|
89353 |
Rev. 2.04 |
HC12 |
N/A |
Rev. 2.04 improves the reset to
Z45N anomaly. |
|||||||||||||||||||
4169 |
2.2.03 |
89353 |
Rev. 2.22 |
HC12 |
N/A |
||||||||||||||||||||
4551 |
4.08.04 |
102750 |
Rev. 1.00 |
HC12 |
N/A |
DEUTZ
3CYL FORD EFI P404C
|
Separated from S0513222 and is now a low
current drive pump. |
||||||||||||||||||
6107 |
6.03.06 |
102750 |
Rev. 1.01 |
HC12 |
N/A |
Add brake release when steer, brake
off delay, rocker steer as a pin selection option. |
|||||||||||||||||||
6388 |
8.10.06 |
102750 |
Rev. 1.02 |
HC12 |
N/A |
DEUTZ 3CYL FORD EFI
P404C FORD EFI2.3L |
Add new 2.3L Ford engine parameter choice and
Hi / Low Current drive pump options. |
||||||||||||||||||
9699 |
11.24.08 |
122924 |
Rev. 1.03 |
HC12 |
N/A |
DEUTZ 2011L03 PERKINS 2.5L FORD EFI 2.3L |
- Add Tier 3 engines –Standardized
on Jumper Configuration pins (J5,J6) for
engines and models, -Add low/high
current propel pump option –Fixed footswitch issue when set to lockout –Fixed
footswitch water ingress causing “Valve to low” fault. |
||||||||||||||||||
10179 |
11.8.10 |
T110571 |
Rev. 1.00 |
164/TI |
N/A |
N/A |
N/A |
N/A |
-
Initial
Release software for
ALC500 GenII PCB only -
Added footswitch priority |
||||||||||||||||
10813 |
9.12.11 |
235476 |
Rev. 2.00 |
164/TI |
NA |
NA |
NA |
NA |
. Fixed issue with footswitch not forcing timeout when
held on startup. |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
S40/45 |
7001 |
3.7.03 |
94771 |
Rev. 1.01 |
HC12 |
N/A |
DEUTZ
3CYL FORD EFI P404C
|
Release software |
|||||||||||||||||
7569 |
4.01.04 |
102259 |
Rev. 1.02 |
HC12 |
N/A |
Tier II parameter and 2 speed implementation. |
|||||||||||||||||||
11189 |
8.10.06 |
102259 |
Rev. 1.05 |
HC12 |
N/A |
DEUTZ 3CYL FORD EFI
P404C FORD EFI2.3L |
Add new 2.3L Ford engine parameter choice and
Hi / Low Current drive pump options;
Rev 1.03 and 1.04 never release
to production |
||||||||||||||||||
15581 |
11.24.08 |
122922 |
Rev. 1.06 |
HC12 |
N/A |
DEUTZ 2011L03 PERKINS 2.5L FORD EFI 2.3L |
- Add Tier 3 engines –Standardized
on Jumper Configuration pins (J5,J6) for
engines and models, -Add low/high
current propel pump option –Fixed footswitch issue when set to lockout –Fixed
footswitch water ingress causing “Valve to low” fault. |
||||||||||||||||||
15851 |
11.8.10 |
T110572 |
Rev. 1.00 |
164/TI |
ONLY FOR VIEWING UPGRADE TO S0823202 |
N/A |
N/A |
N/A |
N/A |
-
Initial
Release software for
ALC500 GenII PCB only -
Added footswitch priority |
|||||||||||||||
16325 |
9.25.11 |
235321 |
Rev. 2.02 |
164/TI |
NA |
NA |
NA |
NA |
- Fixed issue with footswitch not forcing timeout when held on startup. - Fixed calibration issue - Boom stow/out of stow propel
speed. |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
S60/65 |
9154 |
5.28.03 |
94772 |
Rev. 1.00 |
HC12 |
N/A |
|
DEUTZ
3CYL FORD EFI P404C
|
Also installed on Pre-pro 1 #,
Pre-pro 2 # . |
||||||||||||||||
9808 |
4.19.04 |
94772 |
Rev. 1.00 |
HC12 |
N/A |
Tier II parameters filled in manually. |
|||||||||||||||||||
10326 |
8.30.04 |
106349 |
Rev. 1.01 |
HC12 |
N/A |
Tier II engines, separate S60 to
S60 2WD and S60 4WD, change Motor shift functions, Brake release when steer,
brake off delay, rocker steer as a pin select option. |
|||||||||||||||||||
12272 |
9.26.05 |
110161 |
Rev. 1.02 |
HC12 |
N/A |
-Corrected ramping rate on power up
–Recall all default values when valid model selection jumpers are detected
–Turntable ramping in/out Stowed- Update Run Boom Screen - Separate CW ,CCW parameters, and Propel
not stowed in Setup/Machine screen –Modified several default value –Modified
joystick calibration values. |
|||||||||||||||||||
14045 |
8.15.06 |
110161 |
Rev. 1.03 |
HC12 |
N/A |
DEUTZ 3CYL FORD EFI
P404C FORD EFI2.3L |
Add new 2.3L Ford engine parameters |
||||||||||||||||||
19607 |
6.23.08 |
110161 |
Rev. 1.03 |
HC12 |
N/A |
Manually change Pulse/Rev of P404C
engine from 8.9 to 10.6 |
|||||||||||||||||||
20133 |
8.12.08 |
139499 |
Rev. 1.04 |
HC12 |
N/A |
Ford EFI 2.5L Perkins Ford EFI 2.3L Deutz 2011L03 GM 3.0L Perkins 404D |
- Add Tier 3 engines –Standardized
on Jumper Configuration pins (J5,J6) for
engines and models, -Add low/high
current propel pump option –Fixed footswitch issue when set to lockout –Fixed
footswitch water ingress causing “Valve to low” fault. |
||||||||||||||||||
9154 To 21000 |
11.17.10 |
T110561 |
Rev. 1.00 |
164/TI |
ONLY FOR VIEWING UPGRADE TO S0816201 |
N/A |
N/A |
N/A |
N/A |
-
Initial
Release software for ALC500 GenII PCB only -
Added footswitch priority |
|||||||||||||||
9154 To 21000 And S60HC |
9.19.11 |
235411 |
Rev. 2.01 |
164/TI |
NA |
NA |
NA |
NA |
- Fixed issue with footswitch not forcing timeout when
held on startup. |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
S60X/65 |
21001 |
05.25.10 |
139748 |
Rev. 1.00 |
164/TI |
ONLY FOR VIEWING UPGRADE TO S0818202 |
NA |
NA |
NA |
Ford EFI 2.5L Perkins Ford EFI 2.3L Deutz 2011L03 GM 3.0L Perkins 404D Deutz 2011L04i |
-
Initial
Release software for
ALC500 GenII PCB only -
Add Deutz 2011L04 engine -
Add Dual Capacity option -
Add Angle sensor input -
Add footswitch priority -
Change Boom2 input joystick to Rocker Sw. |
||||||||||||||
21489 |
03.17.11 |
T114160 |
Rev. 1.01 |
164/TI |
ONLY FOR VIEWING UPGRADE TO S0818202 |
NA |
NA |
NA |
N/A |
-
Corrected
low voltage issue with Steer and added voltage check for valve power vs. ECU
power |
|||||||||||||||
22666 |
9.19.11 |
235323 |
Rev. 2.02 |
164/TI |
NA |
NA |
NA |
NA |
- Fixed issue with footswitch not forcing timeout when held on startup. - Convert from prototype WebGPI library to 3.10 released library. - Fixed calibration issue - Boom stow/out of stow propel
speed. |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Z80 T-CON |
101 |
5.16.02 |
88055 |
Rev. 1.00 |
167 |
|
Controls set up for prEN280 load
sense. |
||||||||||||||||||
|
|
94609 |
Rev. 1.01 |
167 |
|
Improved leveling. EN280 load sense, used in |
|||||||||||||||||||
238 |
7.2.03 |
94946 |
Rev. 1.02 |
167 |
|
Added one second delay to load
sense. |
|||||||||||||||||||
454 |
6.16.04 |
102410 |
Rev. 1.03 |
167 |
|
Tier II and 12.5kW welder option. |
|||||||||||||||||||
928 |
5.16.06 |
111627 |
Rev. 1.04 |
167 |
|
Activate Dual Motion, change parameters, Hi/Low
generator package |
|||||||||||||||||||
2501 |
11.30.09 |
146360 |
Rev. 1.05 |
167 |
|
Tier III
engines DEUTZ 2011LO4i, PERKINS 804T, CONTINENTAL TME27 Steer hunting corrected Footswitch Priority GHG10 Generator added Prox Kill and Load Sense function
separated Deutz oil PSI shutdown 22psi Fixed Generator 2 spd motor stroke |
|||||||||||||||||||
2511 |
1/5/10 |
146392 |
Rev. 2.00 |
167 |
N/A |
N/A |
|
Hardware change, cannot use on
older machines Safety limit switch monitoring Removed Tier II engine Second window added before
resetting all defaults Load sense system has input to TCON
for redundancy Europe/USA antistall option added Plat Level threshold auto calibration |
|||||||||||||||||
Z80 P-CON |
101 |
5.16.02 |
88052 |
Rev. 1.00 |
HC08A |
|
prEN280 load sense |
||||||||||||||||||
|
|
94610 |
Rev. 1.01 |
HC08A |
|
Improved leveling. EN280 load sense, used in |
|||||||||||||||||||
238 |
7.2.03 |
94947 |
Rev. 1.02 |
HC08A |
|
Added one second delay to load
sense. |
|||||||||||||||||||
928 |
5.16.06 |
111628 |
Rev. 1.04 |
HC08A |
|
Activate Dual Motion, change parameters, Hi/Low
generator package |
|||||||||||||||||||
2501 |
11.30.09 |
146358 |
Rev. 1.05 |
HC08A |
|
Same as TCON S0555105 |
|||||||||||||||||||
2511 |
1/5/10 |
146394 |
Rev. 2.00 |
HC08A |
N/A |
N/A |
|
Must be used with TCON version 2.00 Safety limit switch monitoring Removed Tier II engine Second window added before
resetting all defaults Load sense system has input to TCON
for redundancy Europe/USA antistall option added Plat Level threshold auto calibration |
|||||||||||||||||
Z80 D-CON |
101 |
5.16.02 |
Rev. 1.01 |
HC08 |
N/A |
N/A |
|
Release software |
|||||||||||||||||
|
|
50154 |
Rev. 1.02 |
HC08A |
N/A |
N/A |
|
|
|||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Z135 T-CON |
101 |
3.30.05 |
101002 |
Rev. 1.00 |
167 |
ONLY FOR VIEWING UPGRADE TO S0675202 |
N/A |
N/A |
Work with:
S0677200 S0676201 S0681100 |
Release software |
|||||||||||||||
471 |
1.02.07 |
101002 |
Rev. 1.11 |
|
ONLY FOR VIEWING UPGRADE TO S0675202 |
N/A |
N./A |
See CD part number 119801 for installation instruction
for software and hardware. The
software fixes the following problems: ·
Duetz engine temperature shutdown changed from 248 deg F
to 275 deg F ·
Corrected recovery circuit to lower
the platform to ground ·
Disable steer mode change while driving not works. ·
Added three level password to SCON. ·
Use aux hyd pump to get out of platform overload
conditions ·
the boom cannot be operated with the SCON uncalibrated ·
Improved error message handling ·
Eliminated the P12 axle fault message. ·
Eliminated pre and post leveling Backward compatible only if update hardware LSP1RO and software V1.10
on P-CON and S-CON. |
|||||||||||||||||
|
1154 |
12/31/09 |
139645 |
Rev. 2.00 |
167 |
ONLY FOR VIEWING UPGRADE TO S0675202 |
N/A |
N/A |
Work with:
S0677200 S0676201 S0681100 |
Must be used with SCON version 2.00 and PCON
version 2.00 Tier III engine added Deutz low oil psi changed to 22 LSS1RS/LSS1RO monitoring Platform Leveling parameters GHG10 gen added Load sense and prox kill function separated Error history resolution changed from 1 to 0,01 PBMAO screen locked |
|||||||||||||||
1571 |
9.20.11 |
227202 |
Rev. 2.02 |
167 |
NA |
NA |
Must be used with SCON version 2.00 and PCON version 2.01 1. Modified engine
state machine to only allow high idle 3 seconds after starting engine. |
||||||||||||||||||
??? |
??? |
237071 |
Rev. 3.00 |
167 |
NA |
NA |
S0827300 |
Work with:
S0829300 S0828301 S0681300 |
- Alarms added for P7R, P6R1 and P6R2 faults. |
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Z135
P-CON |
101 |
3.30.05 |
101003 |
Rev. 1.00 |
HCS12 |
ONLY FOR VIEWING UPGRADE TO S0676201 |
N/A |
N/A |
N/A |
Work with:
S0675202 S0677200 S0681300 |
Release software |
||||||||||||||
101 |
8.03.05 |
101003 |
Rev. 1.00 |
HCS12 |
|
N/A |
N/A |
N/A |
Update |
||||||||||||||||
471 |
1.02.07 |
101003 |
Rev. 1.10 |
HCS12 |
ONLY FOR VIEWING UPGRADE TO S0676201 |
N/A |
N/A |
N/A |
See Z135 T-CON comment |
||||||||||||||||
1154 |
12/31/09 |
139646 |
Rev. 2.00 |
HCS12 |
ONLY FOR VIEWING UPGRADE TO S0676201 |
N/A |
N/A |
N/A |
See Z135 T-CON comment |
||||||||||||||||
1571 |
9.20.11 |
227203 |
Rev. 2.01 |
HCS12 |
NA |
NA |
NA |
Must use TCON version 2.02 and SCON 2.00 - Jib U/D valve Fault
Detect Current to 370mA from 850 mA - Do not clear valve status
if already in error. |
|||||||||||||||||
??? |
?? |
237072 |
Rev. 3.01 |
HCS12 |
NA |
L123104 |
NA |
NA |
S0828301 |
Work with:
S0829300 S0827300 S0681100 |
- Modifications to load sense function. |
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
Z135
S-CON |
101 |
3.30.05 |
94978 |
Rev. 1.00 |
HCS12 |
ONLY FOR VIEWING UPGRADE TO S0677200 |
N/A |
N/A |
N/A |
Work with:
S0675202 S0676201 S0681100 |
Release software |
||||||||||||||
471 |
1.02.07 |
94978 |
Rev. 1.10 |
HCS12 |
ONLY FOR VIEWING UPGRADE TO S0677200 |
N/A |
N/A |
N/A |
See Z135 T-CON comment |
||||||||||||||||
1154 |
12/31/09 |
139647 |
Rev. 2.00 |
HCS12 |
N/A |
N/A |
N/A |
See Z135 T-CON comment |
|||||||||||||||||
?? |
?? |
237073 |
Rev. 3.00 |
HCS12 |
NA |
NA |
NA |
S0829300 |
Work
with: S0828301 S0827300 S0681100 |
- Modifications to load sense function. |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||
Z135 D-CON |
101 |
3.30.05 |
101004 |
Rev. 1.00 |
HC08A |
N/A |
N/A |
|
|
Release software |
|||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
SER. # |
Inc. Date |
Hardware Assembly Part # |
Software Revision |
Microcontroller |
PC Install Program (.exe) |
Boot File (.hex Need before Kernel File Download) |
Kernel File (.hex) |
PDA xml File (view/adjust program on board with PDA) |
WebGPI PDA Application File (.hex) |
Backward compatible |
Applicable Engines |
Comments |
|
S100/ S120 T-CON |
101/ 103 |
4.21.00/ 6.20.00 |
*50153 |
Rev. 1.01 |
167 |
N/A |
N/A |
|
* Assembled box with board installed.
Replace with S0277108. prEN280 load
sense. |
||||
131/ 313 |
|
*50153 |
Rev. 1.08 |
167 |
N/A |
N/A |
|
* Assembled box with board
installed. Improved platform leveling and calibration screens. prEN280 load sense |
|||||
186 / 799 |
6.6.03 |
*50153 |
Rev. 1.10 |
167 |
N/A |
N/A |
|
* Assembled box with board
installed. Removed engine over speed diagnostics. Added one second delay to
load sense. EN280 load sense |
|||||
253/ 1018 |
4.05.04 |
102696 |
Rev. 1.11 |
167 |
N/A |
N/A |
|
Tier II and 12.5kW welder option. |
|||||
253/ 1029 |
12.07.04 |
102730 |
Rev. 2.00 |
167 |
|
|
|
N/A |
N/A |
|
Low current drive pump output instead of the
high current output. |
||
757/2667 |
6.15.09 |
146135 |
Rev. 2.10 |
167 |
|
|
N/A |
N/A |
Added Tier III engines: Cummins B3.3T, Deutz
2011L04i, and Perkins 804T. Added
Chassis Tilt Cutout, GHG10 Generator, and High Current Drive Pump
functionality. See SMS p/n 146136 Rev
A for more info/revisions. |
||||
796/2693 |
11.04.09 |
146135 |
Rev. 2.11 |
167 |
|
|
N/A |
N/A |
Fixed bug in Boom Configuration screen, added
Footswitch Priority. See SMS p/n 146136 Rev B for more info/revisions. |
||||
SERV |
4.06.10 |
146135 |
Rev. 2.12 |
167 |
|
|
N/A |
N/A |
Fixed Steering bug. See SMS p/n 146136 Rev C for more info. |
||||
806/2710 |
1.19.10 |
146387 |
Rev. 3.00 |
167 |
|
|
N/A |
N/A |
Cummins B3.3T, Deutz
2011L04i, and Perkins 804T |
Hardware change, cannot use on
older machines. Added Safety limit
switch monitoring and removed Tier II engines. Second window added before resetting all
defaults. Load sense system now has
input to TCON for redundancy. Added
Europe/USA antistall options. See SMS p/n 146388 Rev A for more
info/revisions. |
|||
877 / 2907 |
11.29.10 |
T109426 |
Rev. 3.10 |
167 |
|
|
N/A |
N/A |
Added Shipyard Boom models S3200 and
S3800. Added Numeric Fault Code
display option and Autoshift functionality, restored Propel Upshift/Downshift
Ramping, split Boom Up/Down Speed Limits.
See SMS p/n T109428 Rev A for more info/revisions. |
||||
894 / 3012 |
3.30.11 |
T109426 |
Rev. 3.11 |
167 |
|
|
N/A |
N/A |
Added steering “fix”-once joystick is released.
Wheel(s) will attempt to reach set point three times then stop until the next
steering command is issued. See SMS p/n T109428 Rev B for more
info/revisions. |
||||
? |
? |
T109426 |
Rev. 3.12 |
167 |
|
|
N/A |
N/A |
Use with PCON software
S0813300. |
Solved the problem of
safety trip at Boom angle >= 53 degrees and boom length = 100. Updated strings and
their translation. Modification to the
default parameters. |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S3200/ S3800 |
101D/ 101D |
3.30.11 |
T109426 |
Rev 3.11 |
167 |
|
|
N/A |
N/A |
Cummins B3.3T, Deutz
2011L04i, and Perkins 804T |
Added steering “fix”-once joystick is released.
Wheel(s) will attempt to reach set point three times then stop until the next
steering command is issued. See SMS p/n T109428 Rev B for more
info/revisions. |
||
? |
? |
T109426 |
Rev. 3.12 |
167 |
|
|
N/A |
N/A |
Use with PCON software
S0813300. |
Solved the problem of
safety trip at Boom angle >= 53 degrees and boom length = 100. Updated strings and
their translation. Modification to the
default parameters. |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S100/ S120 P-CON |
101/ 103 |
4.21.00/ 6.20.00 |
62383 |
Rev. 1.01 |
HC08 |
N/A |
N/A |
|
Replace with S0278108. prEN280 load sense |
||||
131/ 313 |
|
62383 |
Rev. 1.08 |
HC08 |
N/A |
N/A |
|
Improved platform leveling and
calibration screens. prEN280 load
sense |
|||||
|
6.6.03 |
62383 |
Rev. 1.10 |
HC08 |
N/A |
N/A |
|
Added one second delay to load
sense. EN280 load sense |
|||||
|
|
62383 |
Rev. 1.08 |
HC08A |
N/A |
N/A |
|
Same software function as S0278108
except used with HC08A microcontroller.
prEN280 load sense |
|||||
186 / 799 |
6.6.03 |
62383 |
Rev. 1.10 |
HC08A |
N/A |
N/A |
|
Same software function as S0278110
except used with HC08A microcontroller.
EN280 load sense |
|||||
757/2667 |
6.15.09 |
146138 |
Rev. 2.10 |
HC08A |
N/A |
N/A |
|
Numerous bug fixes |
|||||
806/2710 |
1.19.10 |
146390 |
Rev. 3.00 |
HC08A |
N/A |
N/A |
|
Revised Load Sense System – Added
additional signal (to TCON) and cross-checking between TCON/PCON. |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S100/ S120 D-CON |
4.21.00/ 6.20.00 |
50154 |
Rev. 1.01 |
HC08 |
N/A |
N/A |
|
|
|||||
|
|
50154 |
Rev. 1.02 |
HC08A |
N/A |
N/A |
|
Same functions as S0279101 software
except used on HC08A microcontroller. |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
MODEL |
SER. # |
Inc. Date |
Hardware
Assembly Part # |
Software
Revision |
Microcontroller |
Compiled
Control Program File Plus1 (*.lhx) Zapi (*.h86) |
Backward
Compatible |
Service
& Diagnostic Application File {for adjusting parameters and
troubleshooting} (*.p1d) |
Adjustable
Parameter Default Value File (*.xml) |
Comments |
Z40 |
104 |
04.04.07 |
110989 |
Rev. A |
Plus1 |
|
|
Only for use with Rev.
A TCON/PCON software. |
||
133 |
07.12.07 |
Rev. B |
Requires Rev B AC
Motor Controller Software |
|||||||
425 |
01.21.08 |
Rev. C |
||||||||
1275 |
07.06.11 |
Rev. D |
Requires 230797A service tool to view Z40 Rev D
diagnostics. Obtaining
Plus+1 Service and Diagnostic Tool |
|||||||
Z40 PCON |
104 |
04.04.07 |
110990 |
Rev. A |
Plus1 |
|
Same as TCON |
|
Only for use with Rev.
A TCON/PCON software. |
|
133 |
07.12.07 |
Rev. B |
Requires Rev B AC
Motor Controller Software |
|||||||
425 |
01.21.08 |
Rev. C |
||||||||
1275 |
07.06.11 |
Rev. D |
Requires 230797A
service tool to view Z40 Rev D diagnostics. Obtaining Plus+1 Service and Diagnostic
Tool | Z40 Rev C to Rev D Upgrade Info |
|||||||
Z40 AC Master |
104 |
04.04.07 |
110665 |
Rev 16 |
Zapi |
|
|
|
Use only with Rev
A TCON/PCON Software |
|
133 |
07.12.07 |
|
Rev. B |
|
|
|
Use only with Rev B,
Rev C or Rev D TCON/PCON Software |
|||
Z40 AC Slave |
104 |
04.04.07 |
110665 |
Rev 16 |
Zapi |
|
|
|
Use only with Rev
A TCON/PCON Software |
|
133 |
07.12.07 |
|
Rev. B |
|
|
|
Use only with Rev B,
Rev C or Rev D TCON/PCON Software |
|||
|
|
|
|
|
|
|
|
|
|
|
S60HC TCON |
13801 |
06.05.06 |
110991 |
Rev. A |
Plus1 |
|
||||
14191 |
08.24.06 |
Rev. B |
|
|||||||
18669 |
01.21.08 |
Rev. C |
|
|||||||
19039 |
04.21.08 |
Rev. A |
|
|||||||
20305 |
12.02.08 |
Rev. B |
|
|
||||||
S60HC SCON |
13801 |
06.05.06 |
110992 |
Rev. A |
Plus1 |
Same as TCON |
|
|
||
14191 |
08.24.06 |
Rev. B |
|
|
||||||
18669 |
01.21.08 |
Rev. C |
|
|
||||||
19039 |
04.21.08 |
Rev. A |
|
Requires different string sensor, harness
update and add’l relay in ground box |
||||||
20305 |
12.02.08 |
Rev. B |
|
|
Model |
Serial |
Inc. Date |
PCON Hardware PN |
GCON Hardware PN |
Microcontroller type |
Software Revision |
Software PN |
Backwards compatible |
Comments |
GR |
GR11-20000 |
06/01/2011 |
137633 |
137692 |
SmartLinkTM |
|
137641B.gff |
|
Initial Release |
GR11-20866 |
09/13/2011 |
137633 |
137692 |
SmartLinkTM |
|
Eliminates F035 nuisance error. Allows for descent delay to be turned off for AUS GS1532 and GS1932 |
|||
QS
|
QS11-1000 |
06/01/2011 |
137633 |
137692 |
SmartLinkTM |
|
137641C.gff |
|
Initial Release |
QS11-1016 |
09/13/2011 |
137633 |
137692 |
SmartLinkTM |
|
Eliminates F035 nuisance error. Allows for descent delay to be turned off for AUS GS1532 and GS1932 |
|||
|
|
|
|
|
|
|
|
|
|
GRC |
GRC-1000 |
06/01/2011 |
137633 |
137692 |
SmartLinkTM |
|
137641C.gff |
|
Initial Release |
GRC-1100 |
09/13/2011 |
137633 |
137692 |
SmartLinkTM |
|
Eliminates F035 nuisance error. Allows for descent delay to be turned off for AUS GS1532 and GS1932 |
|||
|
|
|
|
|
|
|
|
|
|
GS-1530 |
GS30A-110000 |
06/01/2011 |
137633 |
137692 |
SmartLinkTM |
|
137641C.gff |
|
Initial Release |
GS30A-111106 |
09/13/2011 |
137633 |
137692 |
SmartLinkTM |
|
Eliminates F035 nuisance error. Allows for descent delay to be turned off for AUS GS1532 and GS1932 |
|||
GS30C-10000 |
09/13/2011 |
137633 |
137692 |
SmartLinkTM |
|
Initial Release on |
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S80/85 with the ALC-500 control board P/N 81542, serial numbers 3082 through 3423.
1. Click on the file link HERE (Install S0513100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0513100PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application was used on Z60/34 with the ALC-500 control board P/N 89353, serial numbers after 4000. This software is obsolete and should be upgraded to S0513222 if found installed on a machine.
1. Click on the file link HERE (Install S0513200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0513200_PDA.xml).
NOTE: Control boards with this software should be upgraded to S0513222.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application was used on: ALC-500 control board P/N 89353 machines S80/85 with serial numbers 3424 through 3486, Z45/25 serial numbers 21180 through 21563, and Z60/34 serial numbers 4001 through 4168.
1. Click on the file link HERE (Install S0513204.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 89353 S80/85, Z60, or Z45 control boards.
9. For PDA interface to the control card, click HERE (S0513204_PDA.xml).
NOTE: If the machine has been switching models to Z45 Narrow (Z60 machines unable to drive) the board with this software should be upgraded to S0513222.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80/85 with the ALC-500 control board P/N 89353, serial numbers 3486 through 4075; Z45/25 with the ALC-500 control board P/N 89353, serial numbers 21563 through 22050; and Z60/34 with the ALC-500 control board P/N 89353, serial numbers 4168 through 4550.
1. Click on the file link HERE (Install S0513222.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 89353 control board.
9. For PDA interface to the control card, click HERE (S0513222_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z60/34 with the ALC-500 control board P/N 102750, serial numbers after 4550.
1. Click on the file link HERE (Install S0690100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface
to the control card, click HERE
(S0690100_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S40/45 with the ALC-500 control board assembly P/N 94771, serial numbers 7000 through 7568.
1. Click on the file link HERE (Install S0648101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0648101_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S40/45 with the ALC-500 control board assembly P/N 102259, serial numbers after 7568.
1. Click on the file link HERE (Install S0648102.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0648102_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S40/45 with the ALC-500 control board assembly P/N 102259, serial numbers after 11189.
1. Click on the file link HERE (Install S0648105.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0648105_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S40/45 with the ALC-500 control board assembly P/N 122922, serial numbers after 15581.
1. Click on the file link HERE (Install S0648106.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0648106_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S40/45 with the ALC-500 Gen II control board assembly P/N T110572 after serial number 15850.
1. Click on the file link HERE (Install S0823100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S40/45 with the ALC-500 Gen II control board assembly P/N 235321.
1. Click on the file link HERE (Install S0823202.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 control board assembly P/N 94772, after serial numbers 9153.
1. Click on the file link HERE (Install S0649100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0649100_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 control board assembly P/N 106349, serial numbers after 9153.
1. Click on the file link HERE (Install S0649101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
For PDA interface to the control card, click HERE (S0649101_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 control board assembly P/N 110161 after serial number 9807.
1. Click on the file link HERE (Install S0649102.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0649102_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 control board assembly P/N 110161 after serial number 14045.
1. Click on the file link HERE (Install S0649103.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9.
For PDA interface to the control card, click HERE (S0649103_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 control board assembly P/N 110161 after serial number 14045.
1. Click on the file link HERE (Install S0649104.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9.
For PDA interface to the control card, click HERE (S0649104_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N T110561.
1. Click on the file link HERE (Install S0816100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N 235411.
1. Click on the file link HERE (Install S0816201.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z45/Z45 Narrow with the ALC-500 control board assembly P/N 94773, serial numbers 22050 through 23384.
1. Click on the file link HERE (Install S0662100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (Install S0662100_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z45/Z45 Narrow with the ALC-500 control board assembly P/N 106348, serial numbers after 23385.
1. Click on the file link HERE (Install S0662101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (Install S0662101_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z45/Z45N with the ALC-500 control board assembly P/N 110164 after serial number 26999.
1. Click on the file link HERE (Install S0662103.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0662103_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z45/Z45N with the ALC-500 control board assembly P/N 110164 after serial number 30142.
Z45M with the ALC-500 control board assembly P/N 110164 after serial number 100.
1. Click on the file link HERE (Install S0662104.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9.
For PDA interface to the control card, click HERE (S0662104PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z45/Z45N with the ALC-500 control board assembly P/N 139502 after serial number 38511.
Z45M with the ALC-500 control board assembly P/N 139502 after serial number 1423.
1. Click on the file link HERE (Install S0662106.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9.
For PDA interface to the control card, click HERE (S0662106PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z45/Z45N with the ALC-500 Gen II control board assembly P/N T110562.
Z45M with the ALC-500 control board assembly P/N T110562.
1. Click on the file link HERE (Install S0824100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z45/Z45N with the ALC-500 Gen II control board assembly P/N 235473.
Z45M with the ALC-500 control board assembly P/N 235473.
1. Click on the file link HERE (Install S0824200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be
installed. Click
here to open WebGPI Application
Interface Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z60/34 with the ALC-500 control board assembly P/N 102750 after serial number 6107.
1. Click on the file link HERE (Install S0690101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9.
For PDA interface to the control card, click HERE (S0690101_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z60/34 with the ALC-500 control board assembly P/N 102750 after serial number 6388.
1. Click on the file link HERE (Install S0690102.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9.
For PDA interface to the control card, click HERE (S0690102_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z60/34 with the ALC-500 control board assembly P/N 122924 after serial number 9699.
1. Click on the file link HERE (Install S0690103.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9.
For PDA interface to the control card, click HERE (S0690103_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z60/34 with the ALC-500 Gen II control board assembly P/N T110571 after serial number 10178.
1. Click on the file link HERE (Install S0825100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z60/34 with the ALC-500 Gen II control board assembly P/N T110571 after serial number 10178.
1. Click on the file link HERE (Install S0825200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z51M with the ALC-500 control board assembly P/N 110157 after serial number 100.
1. Click on the file link HERE (Install S0717100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0717100_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z51M with the ALC-500 control board assembly P/N 139505 after serial number 503.
1. Click on the file link HERE (Install S0717102.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0717102_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z51M with the ALC-500 Gen II control board assembly P/N T110563 after serial number xxxxx.
1. Click on the file link HERE (Install S0826100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: Z51M with the ALC-500 Gen II control board assembly P/N T110563 after serial number xxxxx.
1. Click on the file link HERE (Install S0826200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80/85 with the ALC-500 control board assembly P/N 102625 after serial number 4075.
1. Click on the file link HERE (Install S0718100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0718100_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80/85 with the ALC-500 control board assembly P/N 122271 after serial number 5861.
1. Click on the file link HERE (Install S0718101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface
to the control card, click HERE
(S0718101_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80/85 with the ALC-500 control board assembly P/N 122271 after serial number 5897.
1. Click on the file link HERE (Install S0718102.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface
to the control card, click HERE
(S0718102_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80/85 with the ALC-500 control board assembly P/N 122731 after serial number 7139.
1. Click on the file link HERE (Install S0718103.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface to the control card, click HERE (S0718103_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80 with the ALC-500 Gen II control board assembly P/N T110570 for Service Parts.
1. Click on the file link HERE (Install S0821100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure ALC500 Gen II to interface the control board.
9. The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80 with the ALC-500 Gen II control board assembly P/N 235403 for Service Parts.
1. Click on the file link HERE (Install S0821201.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure ALC500 Gen II to interface the control board.
9. The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80/85-2008 with the ALC-500 control board assembly P/N 121457 after serial number 8000.
1. Click on the file link HERE (Install S0780100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. For PDA interface
to the control card, click HERE
(S0780100_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80-2008 with the ALC-500 Gen II control board assembly P/N 139745 after serial number 8500.
1. Click on the file link HERE (Install S0819100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80-2008 with the ALC-500 Gen II control board assembly P/N T115457.
1. Click on the file link HERE (Install S0819101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
9. The PDA interface to the control card is no longer available on the ALC500 Gen II hardware.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S80-2008 with the ALC-500 Gen II control board assembly P/N 235322.
1. Click on the file link HERE (Install S0819202.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12 Kernel Files minimum. Click Next.
8. The files will be
installed. Click here to open WebGPI Application Interface
Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N 138748 after serial number 21000.
1. Click on the file link HERE (Install S0818100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick
7. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N T114160.
1. Click on the file link HERE (Install S0818101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick
7. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on: S60/65 with the ALC-500 Gen II control board assembly P/N 235323.
1. Click on the file link HERE (Install S0818202.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick
7. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the control board.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N 50153, serial numbers 101/103 through 130/312 (some machines have been upgraded to S0277108). Machines with this software should be upgraded to S0277108 software (P-CON needs to be upgraded to S0278108 software at the same time).
1. Click on the file link HERE (Install S0277101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 50153 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N 50153, machines after serial numbers 131/313 through 185/798.
1. Click on the file link HERE (Install S0277108.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 50153 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N 50153, machines after serial number 185/798 through 252/1017.
1. Click on the file link HERE (Install S0277110.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 50153 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N 102696, machines after serial number 253/1018.
1. Click on the file link HERE (Install S0277111.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 102696 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N 102730, machines after serial number 253/1029.
1. Click on the file link HERE (Install S0716200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 102730 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N 146135, machines after serial number 756/2666.
1. Click on the file link HERE (Install S0716210.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146135 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N 146135, machines after serial number 795/2692.
1. Click on the file link HERE (Install S0716211.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146135 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N 146135, (Post-production Service release, see Matrix for backwards compatibility)
1. Click on the file link HERE (Install S0716212.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146135 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N 146387, machines after serial number 805/2709.
1. Click on the file link HERE (Install S0812300.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146387 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N T109424, machines after serial number 877/2907.
1. Click on the file link HERE (Install S0812310.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the T109426 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N T109424, machines after serial number 894/3012.
This application is used on S3200/S3800 T-CON control box assembly P/N T109424, machines after serial number 101D/101D.
1. Click on the file link HERE (Install S0812311.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the T109426 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 T-CON control box assembly P/N T109424.
This application is used on S3200/S3800 T-CON control box assembly P/N T109424.
1. Click on the file link HERE (Install S0812312.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the T109426 S100/120 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 P-CON control box assembly P/N 62383, serial numbers 101/103 through 130/312 (some machines have been upgraded to S0277108). Machines with this software should be upgraded to S0278108 software (T-CON needs to be upgraded to S0277108 software at the same time).
1. Click on the file link HERE (Install S0278101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 50153 S100/S120 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/S120 P-CON control box assembly P/N 62383, machine serial numbers 131/313 through 188/798.
1. Click on the file link HERE (Install S0278108.exe)
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 62383 S100/120 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on some S100/S120 P-CON control box assembly P/N 62383, machine serial numbers 131/313 through 188/798.
1. Click on the file link HERE (Install S0278110.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 62383 S100/120 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 and S100/120 D-CON control board assembly P/N 50154, serial numbers 101 and 101/103 respectively.
1. Click on the file link HERE (Install S0279101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 50154 Z80 and S100/120 D-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 T-CON control board assembly P/N 88055, serial numbers 101 through current production machines (some machines have been upgraded to S0555101).
1. Click on the file link HERE (Install S0555100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 88055 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0555100PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 T-CON control board assembly P/N 94609, serial numbers 101 through current production machines (some machines have been upgraded to S0555101).
1. Click on the file link HERE (Install S0555101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 94609 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0555101-PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 T-CON control board assembly P/N 94946, serial numbers 101 through current production machines (some machines have been upgraded to S0555101).
1. Click on the file link HERE (Install S0555102.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 94946 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0555102-PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 T-CON control board assembly P/N 102410, serial numbers after 454.
1. Click on the file link HERE (Install S0555103.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 94946 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0555103-PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 T-CON control board assembly P/N 102410, serial numbers after 928.
1. Click on the file link HERE (Install S0555104.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 94946 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0555104-PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 T-CON control board assembly P/N 146360, serial numbers after 2501.
1. Click on the file link HERE (Install S0555105.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146360 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0555105-PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 T-CON control board assembly P/N 146392, serial numbers after 2511.
1. Click on the file link HERE (Install S0814200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146392 Z80 control board assembly.
9. PDA interface is no longer available
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 P-CON control board assembly P/N 88052, serial numbers 101/ 237 (some machines have been upgraded to S0556101).
1. Click on the file link HERE (Install S0556100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 88052 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0556100_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 P-CON control board assembly P/N 94610, serial numbers 101 through current production machines (some machines have been upgraded to S0556101).
1. Click on the file link HERE (Install S0556101.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 94610 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0556101_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 P-CON control board assembly P/N 94947, serial numbers 101 through current production machines (some machines have been upgraded to S0556101).
1. Click on the file link HERE (Install S0556102.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 94947 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0556102_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 P-CON control board assembly P/N 111628, serial numbers 928.
1. Click on the file link HERE (Install S0556104.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 111628 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0556104_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 P-CON control board assembly P/N 146358, serial numbers 2501.
1. Click on the file link HERE (Install S0556105.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146358 Z80 control board assembly.
9. For PDA interface to the control card, click HERE (Install S0556105_PDA.xml).
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 T-CON control board assembly P/N 146394, serial numbers after 2511.
1. Click on the file link HERE (Install S0815200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146394 Z80 control board assembly.
9. PDA interface is no longer available
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/120 P-CON control board assembly P/N 62383, serial numbers through 185/798 (some machines have been upgraded to S0556101).
1. Click on the file link HERE (Install S0612108.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 62383 Z80 control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/120 P-CON control board assembly P/N 62383, serial numbers after 185/798 (some machines have been upgraded to S0556101).
1. Click on the file link HERE (Install S0612110.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 62383 S100/120 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/120 P-CON control board assembly P/N 146138, serial numbers after 756/2666.
1. Click on the file link HERE (Install S0612210.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146138 S100/120 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on S100/120 P-CON control board assembly P/N 146390, serial numbers after 805/2709.
1. Click on the file link HERE (Install S0813300.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 146390 S100/120 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z80 and S100/120 D-CON control board assembly P/N 50154, serial numbers after 101/103.
1. Click on the file link HERE (Install S0613102.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 50154 Z80 and S100/120 control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 T-CON control board assembly P/N 101002, serial numbers 101 and after.
1. Click on the file link HERE (Install S0675100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 101002 Z135 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 T-CON control board assembly P/N 119789.
1. Click on the file link HERE (Install S0675111.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 119789 Z135 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 T-CON control board assembly P/N 139645.
1. Click on the file link HERE (Install S0675200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 139645 Z135 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 T-CON control board assembly P/N 227202.
1. Click on the file link HERE (Install S0675202.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 227202 Z135 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 T-CON control board assembly P/N ??????.
1. Click on the file link HERE (Install S0827300.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and 167 Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the ???????? Z135 T-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 P-CON control board assembly P/N 101003, serial numbers 101 and after.
1. Click on the file link HERE (Install S0676100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 101003 Z135 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 P-CON control board assembly P/N 119791.
1. Click on the file link HERE (Install S0676110.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 119791 Z135 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 P-CON control board assembly P/N 139646.
1. Click on the file link HERE (Install S0676200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 139646 Z135 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 P-CON control board assembly P/N 227203.
1. Click on the file link HERE (Install S0676201.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be
installed. Click here to open WebGPI Application Interface
Procedure to interface the 227203. Z135 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 P-CON control board assembly P/N ????????.
1. Click on the file link HERE (Install S0828301.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the ?????????. Z135 P-CON control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 S-CON control board assembly P/N 94978, serial number 101 through current production machines.
1. Click on the file link HERE (Install S0677100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 94978 Z135 control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 S-CON control board assembly P/N 119790.
1. Click on the file link HERE (Install S0677110.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 119790 Z135 control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 S-CON control board assembly P/N 139647.
1. Click on the file link HERE (Install S0677200.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 139647 Z135 control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 S-CON control board assembly P/N ????????.
1. Click on the file link HERE (Install S0829300.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8.
The files will be installed.
Click here to open WebGPI
Application Interface Procedure to interface the ??????? Z135 control board assembly.
Note: This installation file is to load the software onto your PC/laptop for use with the WebGPI program.
This application is used on Z135 D-CON control board assembly P/N 101004, serial number 101 through current production machines.
1. Click on the file
link HERE (Install
S0681100.exe).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. When the setup window appears, pick YES on the license agreement.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Pick Custom and click Next.
7. Check all items on the list to install. You need the Application HTML files, Application HEX files, Objects, and HC08A Kernel Files minimum. Click Next.
8. The files will be installed. Click here to open WebGPI Application Interface Procedure to interface the 101004 Z135 control board assembly.
________________________________________________________________________________________________________________________________________________________
Note: Boot file download may be performed with PC/laptop using WebGPI 1.01 or higher, or using a Palm handheld with WebGPI-PDA version 1.30, build 27 or higher.
Note: This installation file is to load the kernel hex file onto your PC/laptop or Palm for use with the WebGPI program.
This Application is used on S100/120 (serial numbers 103/101 through 131/313) T-CON.
1. Click on the file link HERE (Install L0068303.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip. The file will be installed. Pick OK.
7. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI to load the kernel onto the 50153 S100/120 T-CON.
Note: This installation file is to load the kernel hex file onto your PC/laptop for use with the WebGPI program.
This Application is used on S100/120 (serial numbers 103/101 through 131/313) T-CON.
1. Click on the file link HERE (Install L0068304.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip. The file will be installed. Pick OK.
7. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI to load the kernel onto the 50153 S100/120 T-CON.
Note: This installation file is to load the kernel hex file onto your PC/laptop for use with the WebGPI program.
This Application is used on Z80 and Z135 (serial numbers 101 through current production) T-CON.
1. Click on the file link HERE (Install L0068317.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip. The file will be installed. Pick OK.
7. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI to download the Z80 or Z135 boot file.
Note: This installation file is to load the boot file needed to download the kernel onto your PC/laptop for use with the WebGPI program.
This Application is used on HC08 hardware on S100/125, Z80 P-CON and D-CON.
1. Click on the file link HERE (Install L0069000.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip. The file will be installed. Pick OK.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. The file will be installed. Open WebGPI to interface the 81542 S80/85 serial numbers 3082 through 3423.
Note: This installation file is to load the boot file needed to download the kernel onto your PC/laptop for use with the WebGPI program.
This Application is used on some S100/125 (after serial numbers 101/103); Z80 (serial numbers 101 through current production) D-CON, and Z135 (serial numbers 101 through current production) D-CON and P-CON.
1. Click on the file link HERE (Install L0087100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Check all items on the list to install. If you have limited hard drive space, uncheck the documentation. You need the Application HTML files, Application HEX files, Objects, and HC12A Kernel Files minimum. Click Next.
7. The file will be installed.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI to interface the 88052 P-CON or D-CON control board and download boot file.
Note: A PC/laptop or a Palm OS handheld with WebGPI-PDA version 1.30, build 27 or higher, is needed to download a kernel file to a control board.
1. If you do not have the L0047304.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0047304.hex onto your PC/laptop or for use on your Palm OS handheld.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI Download Procedure to download to the control card (Boot File L0069000 must be installed to download this kernel file). Click HERE (Install L0069000.hex boot file).
1. If you do not have the L0048305.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0048305.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use, pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI Download Procedure to download to the control card (Boot File L0069000 must be installed to download this kernel file). Click HERE (Install L0069000.hex boot file).
1. If you do not have the L0048310.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0048310.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGP+ Download Procedure to download to the control card (Boot File L0069000 must be installed to download this kernel file). Click HERE (Install L0069000.hex boot file).
1. If you do not have the L0060303.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0060303.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI Download Procedure to download
to the control card (Boot File L0068303 must be installed to download this
kernel file). Click HERE (Install
L0068303.hex boot file).
1. If you do not have the L0060304.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0060304.hex onto your PC/laptop or Palm OS handheld.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI Download Procedure to download to the control card (Boot File L0068317 must be installed to download this kernel file). Click HERE (Install L0068317.hex boot file).
1. If you do not have the L0060317.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0060317.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI Download Procedure to download to the control card (Boot File L0068317 must be installed to download this kernel file). Click HERE (Install L0068317.hex boot file).
1. If you do not have the L0082100.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0082100.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download the kernel on the 81542 control board on S80/85 serial numbers 3082 through 3423.
9. For download to the control card, click HERE (Install L0082100.hex).
1. If you do not have the L0082101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0082101.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download the kernel to the 89353 control board.
9. For instructions on using a PDA to download to the control card, click HERE (PDA Aplication Download Procedure).
1. If you do not have the L0089400.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0089400.hpex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 62383 control board.
9. For PDA interface to the control card, click HERE (Install L0082101.hex).
1. If you do not have the L0090400.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0090400.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 50154 control board.
1. If you do not have the L0099101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0099101.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 88052 control board.
9. For PDA interface to the control card, click HERE (Install L0082101.hex).
1. If you do not have the L0099102.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0099102.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 94610 and 94947 control board.
9. For PDA interface to the control card, click HERE (Install L0082101.hex).
1. If you do not have the L0091100.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0091100.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 101004 control board.
1. If you do not have the L0113100.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0113100.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 101002 control board.
1. If you do not have the L0123101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0123101.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 101003 control board.
1. If you do not have the L0123101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0123102.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 101003 control board.
1. If you do not have the L0123101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0123102.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 101003 control board.
1. If you do not have the L0125101.hex file loaded in the C:\Program Files\Sauer-Danfoss\WebGPI\KernelFiles folder, click the file link here to install L0125101.hex onto your PC/laptop.
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location for PC/laptop use unless WebGPI has been installed in a different folder). For handheld use (WebGPI-PDA version 1.30, build 27 or higher), pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to interface the 94978 control board.
Note: To use WebGPI-PDA to display or adjust values from a control board with your Palm OS device, you need:
· Palm OS handheld with Palm OS 3.5 or later,
· PC with Windows 95/98/ME/2000/XP/NT (with service pack 3.0 or higher) operating system,
· HotSync serial cable compatible with your handheld (must be serial only, others with a serial and USB split will not work).
· WebGPI-PDA program Version 1.30, Build 10 or higher on your Palm.
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S80/85 with the ALC-500 control board P/N 81542, serial numbers 3080 through 3423 to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0513100PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 81542 S80/85 serial numbers 3082 through 3423.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S80/85 with the ALC500 control board P/N 89353, serial numbers 3080 through 3423 to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0513200_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 89353 Z60 after serial numbers 4000.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S80/85 with the ALC500 control board P/N 89353, serial numbers 3080 through 3423 to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0513204_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 81542 S80/85 serial numbers 3082 through 3423.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on: S80/85 with the ALC-500 control board P/N 89353, serial numbers after 3486, Z45/25 with the ALC-500 control board P/N 89353, serial numbers 21564 through 22050, and Z60/34 with the ALC-500 control board P/N 89353, serial numbers after 4168.
1. Click on the file link HERE (Install S0513222_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 89353 S80/85 control board after serial number 3486.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on: Z51 with the ALC-500 control board assembly P/N 110157, serial numbers after 100.
1. Click on the file link HERE (Install S0717100_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 110157 Z51 control board after serial number 100.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on: Z51 with the ALC-500 control board assembly P/N 139505, serial numbers after 503.
1. Click on the file link HERE (Install S0717102_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA
to interface the 139505 Z51 control board after serial number 503.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on: S80/85 with the ALC-500 control board P/N 102625, serial numbers after 4076.
1. Click on the file link HERE (Install S0718100_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 102625 S80/85 control board after serial number 4075.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on: S80/85 with the ALC-500 control board P/N 122271, serial numbers after 5860.
1. Click on the file link HERE (Install S0718101_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 122271 S80/85 control board after serial number 5860.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on: S80/85 with the ALC-500 control board P/N 122271, serial numbers after 5897.
1. Click on the file link HERE (Install S0718102_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the S80/85 control board after serial number 5897.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on: S80/85 with the ALC-500 control board P/N 122731, serial numbers after 7140.
1. Click on the file link HERE (Install S0718103_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 122731 S80/85 control board after serial number 7140.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on: S80/85-2008 with the ALC-500 control board P/N 121457, serial numbers after 8000.
1. Click on the file link HERE (Install S0780100_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 121457 S80/85 control board after serial number 8000.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
1. Click on the file link HERE (Install S0690100_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 102750 Z60/34 control board after serial number 4551.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
1. Click on the file link HERE (Install S0690101_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 102750 Z60/34 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
1. Click on the file link HERE (Install S0690102_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 102750 Z60/34 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
1. Click on the file link HERE (Install S0690103_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 122924 Z60/34 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 88055, serial numbers 101 to 1?? to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0555100_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 88055 Z80 control board before serial number 238.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 94609, select serial numbers to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0555101_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA
to interface the 94609 Z80 control board on selected
units in
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 94946, select serial numbers to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0555102_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 94946 Z80 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 102410, select serial numbers to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0555103_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 102410 Z80 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 102410, select serial numbers to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0555104_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 102410 Z80 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 146360, select serial numbers to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0555105_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 146360 Z80 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 88052, serial numbers 101 to 237 to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0556100_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 88052 Z80 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 94610, select serial numbers to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0556101_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA
to interface the 94610 Z80 control board on selected units in
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 94947, select serial numbers to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0556102_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 94647 Z80 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 94947, select serial numbers to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0556104_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 111628 Z80 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z80 with the control board P/N 146358, select serial numbers to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0556105_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The file will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 146358 Z80 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S40/45 with the ALC500 control board P/N 94771, after serial number 7000 to display the information from the board onto your Palm OS device.
1. Click on the file link HERE (Install S0648101_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 94771 S40/45 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S40/45 with the ALC500 control board P/N 102259, after serial number 7568 to display the information from the board onto your Palm OS device.
1. Click on the file link HERE (Install S0648102_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 102259 S40/45 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S40/45 with the ALC500 control board P/N 102259, after serial number 11189 to display the information from the board onto your Palm OS device.
1. Click on the file link HERE (Install S0648105_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 102259 S40/45 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S40/45 with the ALC500 control board P/N 122922, after serial number xxxxx to display the information from the board onto your Palm OS device.
1. Click on the file link HERE (Install S0648106_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 122922 S40/45 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S60/65 with the ALC500 control board P/N 94772, after serial number 9807 to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0649100_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 94772 S60/65 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S60/65 with the ALC500 control board P/N 106349, after serial number 10325 to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0649101_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 106349 S60/65 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S60/65 with the ALC500 control board P/N 110161, after serial number 12271 to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0649102_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 110161 S60/65 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S60/65 with the ALC500 control board P/N 110161, after serial number 14044 to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0649103_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 110161 S60/65 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on S60/65 with the ALC500 control board P/N 139499, after serial number 19606 to display or adjust values from the board with your Palm OS device.
1. Click on the file link HERE (Install S0649104_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 139499 S60/65 control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
This XML file is used on Z45/Z45 Narrow with the ALC500 control board P/N 94773, after serial number 22051 to display the information from the board onto your Palm OS device.
1. Click on the file link HERE (Install S0662100_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 94773 Z45/Z45N control board.
10. For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
1. Click on the file link HERE (Install S0662101_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 106348 Z45/Z45N control board.
For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
1. Click on the file link HERE (Install S0662103_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 110164 Z45/Z45N control board.
For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
1. Click on the file link HERE (Install S0662104_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 110164 Z45/Z45N/Z45M control board.
For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
Note: This installation file is to load the software onto your PDA for use with the WebGPI-PDA program.
1. Click on the file link HERE (Install S0662106_PDA.xml).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick Browse and select the location of the WebGPI folder in your Palm user directory on you computer (Example: C:\Palm\{user name}\WebGPI). Pick OK.
6. Click Unzip.
7. The files will be installed. Select Close.
8. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
9. Open WebGPI-PDA to interface the 139502 Z45/Z45N/Z45M control board.
For viewing/adjusting values with a control board using a PDA, click HERE (WebGPI-PDA Application Interface Procedure).
________________________________________________________________________________________________________________________________________________________
PDA HEX File Installation
Note: To use WebGPI-PDA to download software to a control board, you need
· Palm OS handheld with Palm OS 3.5 or later,
· PC with Windows 95/98/ME/2000/XP/NT (with service pack 3.0 or higher) operating system,
· HotSync serial cable compatible with your handheld (must be serial only, others with a serial and USB split will not work).
· WebGPI-PDA software loaded on your Palm handheld.
This HEX file was used on S100/120 T-CON control box P/N 50153, serial numbers 101/103 through 130/312 to download the application to the control board using your Palm OS device.
Note: Control boards with this software should be upgraded to S0277108 software for units with prEN280 load sense system and S0277110 software for EN280 load sense system. Updating from S0277101 requires both a boot file and kernel file update as well. (Boot File L0068304 and Kernel File L0060304)
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S100/120 T-CON control box P/N 50153, after serial numbers 130/312 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0277108.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. (Note: Palm with can only be used to download this software. There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)
8. Open WebGPI to download this application to the 50153 control box on S100/120. This board uses a 167 Microcontroller type.
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S100/120 T-CON control box P/N 50153, after serial numbers 130/312 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0277110.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. (Note: Palm can only be used to download this software. There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)
8. Open WebGPI to download this application to the 50153 control box on S100/120.
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S100/120 T-CON control box P/N 50153 and 102696, after serial numbers 130/312 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0277111.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. (Note: Palm can only be used to download this software. There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)
8. Open WebGPI to download this application to the 50153 and 102696 control box on S100/120.
This HEX file was used on S100/120 P-CON control box P/N 62383, serial numbers 101/103 through 130/312 to download the application to the control board using your Palm OS device.
Note: Control boards with this software should be upgraded to S0278108 software for units with prEN280 load sense system and S0278110 software for EN280 load sense system. Updating from S0278101 requires a kernel file update as well. (Kernel File L0048310)
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S100/120 T-CON control box P/N 62383, after serial numbers 130/312 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0278108.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. Click Next. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. (Note: Palm can only be used to download this software. There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)
8. Open WebGPI to download this application to the 62383 control board. This board uses a HC08 Microcontroller type.
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S100/120 T-CON control box P/N 62383, after serial numbers 130/312 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0278110.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. (Note: Palm can only be used to download this software. There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)
8. Open WebGPI to download this application to the 62383 control board. This board uses a HC08 Microcontroller type.
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 and S100/120 D-CON control board assembly P/N 50154, serial numbers 101 and 101/103 respectively the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0279101.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm. (Note: Palm can only be used to download this software. There is no file for adjusting/viewing information on the card with WebGPI-PDA for this software.)
8. Open WebGPI to download this application to the 50154 control board. This board uses a HC08 Microcontroller type.
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S80/85 with the ALC-500 control board P/N 81542, serial numbers 3080 through 3423 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0513100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 81542 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
This HEX file was used on Z60 with the ALC-500 control board P/N 89353, serial numbers 4001.
Note: All control boards with this software should be upgraded to S0513222 software.
This HEX file is used on S80/85, Z60, and Z45 with the ALC-500 control board P/N 89353, serial numbers 3424 / 4001 / 21180 through 3486 / 4168 / 21563, respectively.
Note: Control boards with this software should be upgraded to S0513222 software.
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S80/85, Z60, and Z45 with the ALC-500 control board P/N 89353, serial numbers 3487 / 4169 / 21564 through current/ current / 22050, respectively.
1. Click on the file link HERE (Install S0513222.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 89353 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S80/85 with the ALC-500 control board P/N 102625, serial numbers after 4075.
1. Click on the file link HERE (Install S0718100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 102625 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S80/85 with the ALC-500 control board P/N 122271, serial numbers after 5861.
1. Click on the file link HERE (Install S0718101.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 122271 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S80/85 with the ALC-500 control board P/N 122271, serial numbers after 5898.
1. Click on the file link HERE (Install S0718102.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 122271 control board.
9.
For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application
Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S80/85 with the ALC-500 control board P/N 122731, serial numbers after 7140.
1. Click on the file link HERE (Install S0718103.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 122731 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S80/85-2008 with the ALC-500 control board P/N 122457, serial numbers after 8000.
1. Click on the file link HERE (Install S0780100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 122457 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z60 with the ALC-500 control board P/N 102750, serial numbers after 4551.
1. Click on the file link HERE (Install S0690100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 102750 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z60 with the ALC-500 control board P/N 102750, serial numbers after 6107.
1. Click on the file link HERE (Install S0690101.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 102750 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z60 with the ALC-500 control board P/N 102750, serial numbers after 6388.
1. Click on the file link HERE (Install S0690102.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 102750 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z60 with the ALC-500 control board P/N 122924, serial numbers after xxxx.
1. Click on the file link HERE (Install S0690103.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 122924 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 T-CON control board P/N 88055, serial numbers 101 through 237 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0555100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 88055 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
This HEX file is used on Z80 T-CON control board P/N 94609, select serial numbers up to 237.
Note: Control boards with this software should be upgraded to S0555102 software.
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 T-CON control board P/N 94946, after serial number 237 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0555102.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 94946 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 T-CON control board P/N 102410, after serial number 453 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0555103.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 102410 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 T-CON control board P/N 102410, after serial number 453 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0555104.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 102410 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 T-CON control board P/N 146360, after serial number 2501 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0555105.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 146360 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 P-CON control board P/N 88052, serial numbers 101 through 237 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0556100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 88052 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
This HEX file is used on Z80 control board P/N 94610, select serial numbers up to 237.
Note: Control boards with this software should be upgraded to S0556102 software.
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 control board P/N 94947, after serial number 237 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0556102.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 94947 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 control board P/N 111628, after serial number 928 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0556104.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 111628 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 control board P/N 146358, after serial number 2501 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0556105.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 146358 control board.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z80 and S100/120 D-CON control board assembly P/N 50154, serial numbers 101 and 101/103 respectively the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0613102.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 62383 control board. This board uses a HC08A Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S40/45 with the ALC-500 control board P/N 94771, after serial number 7000 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0648101.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 94771 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S40/45 with the ALC-500 control board P/N 102259, after serial number 7568 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0648102.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 102259 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S40/45 with the ALC-500 control board P/N 102259, after serial number 11189 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0648105.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 102259 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S40/45 with the ALC-500 control board P/N 122922, after serial number xxxxx to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0648106.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 122922 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S60/65 with the ALC-500 control board P/N 94772, after serial number 9153 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0649100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 94772 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S60/65 with the ALC-500 control board P/N 106349, after serial number 10325 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0649101.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 106349 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S60/65 with the ALC-500 control board P/N 110161, after serial number 12272 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0649102.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 110161 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S60/65 with the ALC-500 control board P/N 110161, after serial number 14044 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0649103.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 110161 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on S60/65 with the ALC-500 control board P/N 139499, after serial number 19607 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0649104.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 139499 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z45 IC with the ALC-500 control board P/N 94773, after serial number 22050 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0662100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 94773 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z45 IC with the ALC-500 control board P/N 106348, after serial number 23384 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0662101.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 106384 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z45 IC with the ALC-500 control board P/N 106348, after serial number 23384 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0662103.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 106384 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z45 IC with the ALC-500 control board P/N 110164, after serial number 30141 to download the application to the control board using your Palm OS device.
And Z45M with the ALC-500 control board P/N 110164, after serial number 100.
1. Click on the file link HERE (Install S0662104.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 110164 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z45 IC with the ALC-500 control board P/N 139502, after serial number 38093 to download the application to the control board using your Palm OS device.
And Z45M with the ALC-500 control board P/N 139502 after serial number 1422.
1. Click on the file link HERE (Install S0662106.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 139502 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z51 with the ALC-500 control board P/N 110157, after serial number 100 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0717100.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 110157 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
Note: This installation file is to load the application software onto your PDA for use with the WebGPI-PDA program.
This HEX file is used on Z51 with the ALC-500 control board P/N 139505, after serial number 503 to download the application to the control board using your Palm OS device.
1. Click on the file link HERE (Install S0717102.hex).
2. On Internet Explorer 5 or 5.5, when the window pops up asking, “What would you like to do with this file?”, select “Run this program from its current location.” And press OK. For Internet Explorer 6 the File Download window pops up “Would you like to open the file or save it to your computer?” Select Open.
3. On Internet Explorer 5 or 5.5, when the window pops up asking, “Do you want to install and run…?”, pick Yes.
4. If a window appears about WinZip Self-Extractor licensing, pick OK.
5. Pick the location of the WebGPI folder on you computer (Recommend using the default location unless WebGPI has been installed in a different folder). Click Next.
6. The file will be installed.
7. HotSync Palm to PC/laptop to load the file in WebGPI-PDA program on the Palm.
8. Open WebGPI to download this application to the 139505 control board with the HC12 Microcontroller type.
9. For downloading this software onto a control board using a PDA, click HERE (WebGPI-PDA Application Download Procedure).
________________________________________________________________________________________________________________
To interface with a control board, you need:
· WebGPI version 1.01a or later installed on the computer,
· Available COM port,
· RS-232 cable (serial cable, 9-pin),
· For S100/120 machines T-Harness part number 75094,
· Internet Explorer 5.0 or later, and
· The appropriate application (*.exe) installed on the computer.
________________________________________________________________________________________________________________________________________________________
Not available for
S100/120 control boards.
Note: To interface with a control board using WebGPI-PDA, you need a
· Palm OS handheld with Palm OS 3.5 or later,
· Gender changer Radio Shack part number 950-025x or equivalent,
· Null Modem cable or adapter Female DB9 – Male DB9,
· appropriate xml or hex file installed on Palm (see above for correct selection of files),
· and a HotSync serial cable compatible with your handheld (must be serial only, others with a serial and USB split will not work).
· WebGPI-PDA program Version 1.30, Build 10 or higher on your Palm.
________________________________________________________________________________________________________________________________________________________
To interface with a control board, you need
· WebGPI version 1.01a or later installed on the computer,
· Available COM port,
· RS-232 cable,
· For S100/120 machines T-Harness part number 75094,
· And the appropriate application (*.exe) installed on the computer.
________________________________________________________________________________________________________________________________________________________
To download the application to a control board, you need:
· WebGPI version 1.01a or later installed on the computer,
· Available COM port,
· RS-232 cable,
· For S-1XX machines T-Harness part number 75094, and
· The appropriate application (*.exe) installed on the computer.
________________________________________________________________________________________________________________________________________________________
To download the application to a control board, you need:
· WebGPI version 3.0 or later installed on the computer,
· Available COM port,
· RS-232 cable,
· The appropriate application (*.exe) installed on the computer.
a) If you are updating the software on the control card, look at each valve function and record the threshold and max out value for each function (Example: Fwd, Rev, Boom 1 Up, Boom 1 Down, etc…).
________________________________________________________________________________________________________________________________________________________
Not available for S100/120 control boards and ALC500 Gen
II control board
Note: To interface with a control board using WebGPI-PDA, you need a
· Palm OS handheld with Palm OS 3.5 or later,
· Gender changer Radio Shack part number 950-025x or equivalent,
· Null Modem cable or adapter Female DB9 – Male DB9,
· WebGPI-PDA program Version 1.30, Build 10 or higher on your Palm.
· Appropriate xml and hex file installed on Palm (see table above for correct selection of files), and
· A HotSync serial cable compatible with your handheld (must be serial only, others with a serial and USB split will not work).
________________________________________________________________________________________________________________________________________________________
Note: To interface with a control board using PLUS+1 Service Tool Software, you need a
(NOTE: Internet
access required)
1. Fill out the PLUS+1 GUIDE Download Request
Form on the Sauer-Danfoss website. Click here (Request File) or copy and paste
the link below into a browser http://www.sauer-danfoss.com/Products/MobileElectronics/PLUS1Guide/PLUS1GuideDownloads/PLUS1GUIDEServiceToolSoftwareLicense/RequestForm/index.htm
2. After hitting Send check your email for a
message from PLUS+1 License Auto Activation. The subject line will be “Plus+1
GUIDE Web Site Registration”. Click on the PLUS+1 download link in the message.
3. The link opens a browser page titled PLUS+1
Software Download & License. Select the GUIDE Service Tool (free service
tool only) download and install it on your computer. The download & license
are free and the license does not expire.
4. You should now be able to use the Service
Tool part of PLUS+1 GUIDE.
1. Connect CABLE,PROGRAMMING,PLUS1 (P/N 119604) to USB port on laptop.
2. Connect HARNESS
PROGRAM CAN PLUS1 (P/N 110803) to cable.
3. Connect harness to S60HC next to ground
box.) Unplug the terminating resistor. Insert receptacle on the programming
harness unto the plug from which the terminating resistor was removed. Plug the terminating resistor that was removed
unto the plug on the programming harness.
4. Turn key switch to ground and cycle power.
5. Start
Plus+1 Service tool on the PC by clicking on its icon.
a. Plus+1
Service Tool program will scan connected controller automatically. Note: To scan connected Plus 1 controllers
again press F8 or select Scan System from File menu.
6. Green
block with word Connect will be
displayed at the bottom of the Plus+1 Service Tool program window, indicating
successful connection between PC and Plus 1 controller.
7. Click on the file open icon and browse to the directory where the diagnostic file is stored. The diagnostic file has a *.P1D file name extension. The S60HC diagnostic file is named “TCON-SCON SERVICE TOOL_REVA.P1D.”
a. If “Replace ECU” warning message appears, click Cancel.
1. Perform instructions in section C.
2. Click
File Download icon, or select File Download from File menu.
3. Menu
will roll down on the left side of the tool in Diagnostic Navigator tab.
4. Click
on Controller Application (in bold)
on the menu in the Diagnostic Navigator
tab. Select appropriate application to download from Open file for download dialog window and click Open button.
a. Verify the SCON software is going to the
correct node.
|
File Download SCON: 1st node
5. Plus+1
Service Tool program will read application file and display its information.
Make sure correct application file was selected.
a. Note: The following warning message could pop-up: click Ignore button.
6. Click
Start Download button to begin
downloading.
a. Note: The follow message pop-up:
b. Confirm
new application type.
7. Running
bar in Plus+1 Service Tool will be indicating downloading progress. LED on
Plus+1 controller could blink randomly.
8. After
downloading is complete (for both SCON and TCON), Plus+1 Service Tool will scan
connected controller automatically and display downloaded application
information in Diagnostic Navigator
tab, under sub tree Controller
Application (click + to expand information sub tree). Make sure: App Id, App
a. Note: To scan connected Plus 1
controllers again press F8 or select
Scan System from File menu.
SCON TCON
9. Close
Plus+1 Service Tool program, switch OFF power to Plus 1 controller and unplug
the programming harness and replace the terminating resistor receptacle to it’s
mating plug on the S60HC
10. Plus+1
controller is programmed.
11. Set
defaults.
12. Perform a
full system calibration per Service Manual.
8. Connect CABLE,PROGRAMMING,PLUS1
(P/N 119604) to USB port on laptop.
9. Connect HARNESS
PROGRAM CAN PLUS1 (P/N 110803) to cable.
10. Connect harness to Z40 next to ground box.)
Unplug the terminating resistor. Insert receptacle on the programming harness
unto the plug from which the terminating resistor was removed. Plug the terminating resistor that was
removed unto the plug on the programming harness.
11. Turn key switch to ground and cycle power.
12. Start
Plus+1 Service tool on the PC by clicking on its icon.
a. Plus+1
Service Tool program will scan connected controller automatically. Note: To scan connected Plus 1 controllers
again press F8 or select Scan System from File menu.
13. Green block
with word Connect will be displayed
at the bottom of the Plus+1 Service Tool program window, indicating successful
connection between PC and Plus 1 controller.
14. Click on the file open icon and browse to the directory where the diagnostic file is stored. The diagnostic file has a *.P1D file name extension.
a. If “Replace ECU” warning message appears, click Cancel.
13. Perform instructions in section Connecting to Plus+1 on Z40.
14. Click File Download icon, or select File Download from File menu.
File Download
15. The select
target ECU box will pop up. Select 0,1 -
Z40TurntableControl for the first download. Click OK.
Target Controller
16. Click on Controller Application (TCON 110985) in
the Open application for download
dialog window and click Open button.
Z40
TCON Z40
PCON
17. Plus+1
Service Tool program will read application file for download and display its
information. Make sure correct application file was selected.
a. Note: The following warning message could pop-up: click Ignore button.
18. Click Start Download button to begin
downloading.
a. Note: The following message may pop-up:
b. Confirm
new application type. Type in the window: Z40TCON
or PCON, depending on which
application will be downloaded and press OK.
(case sensitive)
c. Note: The following warning message could pop-up: click Ignore button.
19. Running bar
in PLUS+1 Service Tool will be indicating downloading progress. LED on PLUS+1
controller could blink randomly.
20. After
downloading is complete (for both TCON and PCON), Plus+1 Service Tool will scan
connected controller automatically and display downloaded application
information in Diagnostic Navigator
tab, under sub tree ECU List:
Z40Turntable/PlatformControl: Application (click + to expand information
sub tree). Make sure: App Id, App
a. Note: To scan connected Plus 1
controllers again press F8 or select
Scan System from File menu.
TCON PCON
21. Close
Plus+1 Service Tool program, switch OFF power to Plus 1 controller and unplug
the programming harness and replace the terminating resistor receptacle to it’s
mating plug on the Z40
22. Plus+1
controller is programmed.
23. Set
defaults.
24. Perform a
full system calibration per Service Manual.
Notes:
Procedure:
FUNCTION TARGET
TIME
Secondary Boom Up 32
- 36 sec
Secondary Boom Down 32
- 36 sec
Primary Boom Up 26
- 30 sec
Primary Boom Down 26
- 30 sec
Primary Boom Extend 18
- 22 sec
Primary Boom Retract 18
- 22 sec
Jib Boom Up 16
- 20 sec
Jib Boom Down 16
- 20 sec
Platform Rotate(CW/CCW) 10
- 14 sec
Turntable Rotate(CW/CCW) 62 - 68 sec
Jib Rotate (CW/CCW) 16
- 20 sec
Notes:
Procedure:
FUNCTION TARGET
TIME
Secondary Boom Up 32
- 36 sec
Secondary Boom Down 32
- 36 sec
Primary Boom Up 26
- 30 sec
Primary Boom Down 26
- 30 sec
Primary Boom Extend 18
- 22 sec
Primary Boom Retract 18
- 22 sec
Jib Boom Up 16
- 20 sec
Jib Boom Down 16
- 20 sec
Platform Rotate(CW/CCW) 10
- 14 sec
Turntable Rotate(CW/CCW) 62 - 68 sec
Jib Rotate (CW/CCW) 16
- 20 sec
The Drive Priority using the jumper
wires is not available on Revision 2.04 and early
Note: When using jumpers, One
jumper on J5 and drive mode on J6 must be selected at a minimum. Pin 6 to pin 11 may be selected in addition
to drive mode to activate options. Using
Jumpers J5 and J6 will reset all parameters to defaults including Joysticks and
and sensors.
For example: to set
S80/85 4WD, Deutz 2011L04i engine, Drive Priority:
Perform this procedure
with the boom in the stowed position.
1.
Pull out the
red Emergency Stop button to the on position at ground control.
2.
Turn the key
switch to Platform control. Do not start
the engine
3.
Push in the
Platform control red Emergency Stop button to the off position.
4.
Do not press
down the foot switch.
5.
Locate
J5-Engine connector on the ALC500. Place
wire jumper between COM and Pin 11.
6.
Locate
J6-Model connector on the ALC500. Place
wire jumper from COM to Pin 1 and Pin 11.
7.
Move and
hold the Drive Enable toggle switch in the Right (or Left) position and pull
out the red Emergency Stop button to the on position.
8.
When the
alarm sounds, release the drive enable toggle switch.
Note: - if alarm sounds for about 2 seconds and
stops, settings are stored go to step 9.
-
If alarm
sounds for 1 second ON and 1 second OFF continually, jumpers are not making
contact to connector’s pins, check the jumpers and repeat procedure from 3 to
end.
-
If alarm
continues to sound, push E-stop to off position, one of the jumpers is not
correct, check jumper connections and repeat procedure from 3 to end.
9.
Push in the
Platform control red Emergency Stop button to the off position.
10. Remove all jumpers.
11. Calibrate machine.
TABLE A, J5 ENGINES FOR EACH MACHINES MODEL.
Pin # |
J5- ENGINES |
S40/45 |
S60/65 |
S80/85 |
S80/85 VP |
Z45 |
Z51 |
Z60 |
Com. |
COM |
COM |
COM |
COM |
COM |
COM |
COM |
COM |
1 |
Duetz 2011L04 |
|
|
X |
|
|
|
|
2 |
Ford EFI 2.5L |
X |
X |
X |
|
X |
X |
X |
3 |
Perkins 404C/704 |
X |
X |
X |
|
X |
|
X |
4 |
Ford EFI 2.3L |
X |
X |
|
|
X |
X |
X |
5 |
Continental TME27 |
|
|
X |
X |
|
|
|
6 |
Duetz 2011L03 |
X |
X |
|
|
X |
X |
X |
7 |
Deutz F4L913 |
|
|
X |
|
|
|
|
8 |
GM 3.0L |
|
X |
X |
|
|
|
|
9 |
Perkins 804 |
|
|
X |
X |
|
|
|
10 |
Perkins 404D |
X |
X |
|
|
X |
X |
X |
11 |
Deutz 2011L04i |
|
|
X |
X |
|
|
|
TABLE B, J6 Model and Option for each Type of
Machines.
Pin # |
J5- options |
All ALC500 Machines |
Com. |
COM |
COM |
1 |
4WD (Z45) |
X |
2 |
2WD (Z45N) |
X |
3 |
Spare |
|
4 |
Spare |
|
5 |
Spare |
|
6 |
Rocker Boom2 option |
(S60 High Capacity) |
7 |
Dual Capacity option |
(S60/S80) |
8 |
Low Current Pump |
X |
9 |
High Current
Pump |
X |
10 |
Rocker Steer |
X |
11 |
Drive Priority |
X |